GUI reference
R&S
®
ZNA
510
User Manual 1178.6462.02 ─ 20
●
sending the high voltage level in active state and the low level otherwise ("Active
High"), or vice versa ("Active Low").
Note
that pulse generator pulses cannot be indicated using high and low voltage lev-
els.
Remote command:
TRIGger:CHANnel<Ch>:AUXiliary<n>:STYPe
Delay
Specifies the delay of the trigger signal relative to the selected
If pulses are used as trigger out signals, the delay is defined relative to the start or end
of the sweep event (see
Remote command:
TRIGger:CHANnel<Ch>:AUXiliary<n>:DELay
Width
If pulses are used as trigger out signals (see
on page 509), this parame-
ter specifies the pulse width.
Remote command:
TRIGger:CHANnel<Ch>:AUXiliary<n>:DURation
Position
If pulses are used as trigger out signals (see
on page 509), the pulses
can either indicate the "Start" or "End" position of the related sweep event (see
on page 509). Choose the suitable position setting according to the action
to be triggered.
Note
that for the "Pulse Generator"
only the "Start" position can be used.
Remote command:
TRIGger:CHANnel<Ch>:AUXiliary<n>:POSition
5.10.4
Sweep Control tab
Allows you to control the sweep execution.
The availability of certain settings depends on the selected
.
Sweep Softtool