CALCulate:TDVSwr...
CALCulate:TDVSwr[:STATe]
<Boolean>
Enables/disables time domain site VSWR measurements.
Parameters:
<Boolean>
ON | OFF – TD-VSWR on or off.
*RST:
OFF
Manual operation:
See
7.3.1.23
CALCulate:TRANsform...
The
CALCulate:TRANsform...
commands convert measured data from one repre-
sentation to another and control the transformation into the time domain (see
ter 4.7.2, "Time domain analysis"
CALCulate<Chn>:TRANsform:COMPlex
........................................................................ 1044
CALCulate<Chn>:TRANsform:IMPedance:RNORmal
...................................................... 1045
CALCulate<Chn>:TRANsform:TIME[:TYPE]
................................................................... 1045
CALCulate<Chn>:TRANsform:TIME:CENTer
.................................................................. 1046
CALCulate<Chn>:TRANsform:TIME:DCHebyshev
.......................................................... 1047
CALCulate<Chn>:TRANsform:TIME:LPASs
....................................................................1047
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam
...................................................1047
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam:CONTinuous
............................... 1048
CALCulate<Chn>:TRANsform:TIME:LPASs:DCSParam:EXTRapolate
.............................. 1049
CALCulate<Chn>:TRANsform:TIME:LPFRequency
......................................................... 1049
CALCulate<Chn>:TRANsform:TIME:RESolution:EFACtor
................................................ 1049
CALCulate<Chn>:TRANsform:TIME:SPAN
.....................................................................1049
CALCulate<Chn>:TRANsform:TIME:STARt
.................................................................... 1050
CALCulate<Chn>:TRANsform:TIME:STATe
.................................................................... 1050
CALCulate<Chn>:TRANsform:TIME:STIMulus
................................................................1051
CALCulate<Chn>:TRANsform:TIME:STOP
.....................................................................1051
CALCulate<Chn>:TRANsform:TIME:WINDow
.................................................................1052
CALCulate<Chn>:TRANsform:TIME:XAXis
.....................................................................1052
CALCulate<Chn>:TRANsform:COMPlex
<Result>
Converts S-parameters into converted (matched-circuit) Y-parameters or Z-parameters
and vice versa, assuming that port no. i is terminated with Z
0i
so that the three parame-
ter sets are equivalent and the following formulas apply:
SCPI command reference