Command reference
R&S
®
ZNB/ZNBT
903
User Manual 1173.9163.02 ─ 62
CALCulate:FMODel:EZD:COUPon:MEASure
....................................................................903
CALCulate:FMODel:EZD:COUPon:MEASure:FILename
.................................................... 903
CALCulate:FMODel:EZD:COUPon:MEASure:FILename:CLEar
.......................................... 903
CALCulate:FMODel:EZD<Ph_pt>:COUPon[:STATe]
.......................................................... 904
CALCulate:FMODel:EZD:DCEXtrapolat
............................................................................904
CALCulate:FMODel:EZD:DUT:MEASure
.......................................................................... 904
CALCulate:FMODel:EZD:DUT:MEASure:FILename
...........................................................904
CALCulate:FMODel:EZD:DUT:MEASure:FILename:CLEar
.................................................905
CALCulate:FMODel:EZD<Ph_pt>:DUT[:STATe]
.................................................................905
CALCulate:FMODel:EZD:GENerate:SIDE<1|2>
................................................................ 905
CALCulate:FMODel:EZD:IMPedance
............................................................................... 906
CALCulate:FMODel:EZD:IMPedance:BWIDlimit
................................................................906
CALCulate:FMODel:EZD:IMPedance:REFerence
..............................................................906
CALCulate:FMODel:EZD:PORT:ORDer
............................................................................906
....................................................................................907
................................................................................ 907
CALCulate:FMODel:EZD<Pt>:RUN[:STATe]
......................................................................907
CALCulate:FMODel:EZD:COUPon:MEASure
For a fixture modeling with the Easy De-embedding (EZD) tool, this command starts
the measurement of the symmetrical 2xThru coupon at the active ports (see
CALCulate:FMODel:EZD<Ph_pt>:COUPon[:STATe]
Usage:
Event
Options:
R&S
ZNB/ZNBT-K210
Manual operation:
See
"Measure / Measure Open / Measure Short"
CALCulate:FMODel:EZD:COUPon:MEASure:FILename
<String>
For a fixture modeling with the EZD tool, this command loads the coupon properties
from a Touchstone file.
Parameters:
<String>
Path to the Touchstone file, either absolute or relative to the
selected working directory (
Options:
R&S
ZNB/ZNBT-K210
Manual operation:
See
"Load File / 1x Open Preset / 1x Short Preset"
CALCulate:FMODel:EZD:COUPon:MEASure:FILename:CLEar
Invalidates the file path previously set using
.
Usage:
Event
Options:
R&S
ZNB/ZNBT-K210
SCPI command reference