R&M Materials Handling, Inc
STAGEMAKER
®
Concert Hoist
Springfield, Ohio USA
Technical Guide
:
800 955-9967
June 2009
www.rmhoist.com
RM-STGMKR-TG-2002-6-ENG.doc
31
®
5.6 Configuration C – 8 Channel, 3
rd
-party Controller
Recommended cables & fittings:
A) Power supply to controller –
Power Connector - 3P-4W, 60A, 250VAC Pin and Sleeve connector - ME460C9 (Mennekes Electronics)
or 473317FX (EPIC / LAPP) or HBL460C9W (Hubbell), Power Cable - 6AWG, 4 conductor, SOOW
B) Power and Control Connector at hoist – 19 pin SX19LMB (Socapex) or EPIC 10.0810 NP hood + EPIC
10.1950 3/4" NPT strain relief, Power and Control Connector at Controller – 19 pin SX19LFB
(Socapex) or EPIC 10.0800 NP hood + EPIC 10.1940 3/4" NPT strain relief, Power Cable
between controller and hoist - 12AWG, 4 conductor SOW, Belden MMICS shielded cable recommended
for control cable – 16 AWG, 7 conductor.
C) Control - between Controller and E-stop operator console – E-Stop Connector Micro Console end -
Neutrik NC5FX, E-Stop Connector Controller end - Neutrik NC5MX, E-Stop Cable - Belden 8465
D) Ethernet connections – controller to remote, controller to network hub, E-stop operator console to
network hub, computer to network hub - Ethernet Connector - RJ45 8 position, Ethernet Connector Shell
- Neutrik NE8MC, Ethernet Cable - Belden 1583R or Link USA LK ETN2
Customer is responsible for proper sizing of power cables.
Network Hub
E-stop Operator
Console
Computer
Controller
Option: Remote
Ethernet Connection
High Voltage Connection
Low Voltage Connection
Power
Supply
B
A
C
D
D
D
D