FX1- 4N1 Control Settings con’t
RANDELL CONTROL CYCLE SETTINGS
FX1-
4N1
RANDELL CONTROL CYCLE SETTINGS
FX1-
4N1
DIXELL PART NUMBER XB570L-4R0F1
DIXELL PART NUMBER XB570L-4R0F1
RANDELL PART NUMBER
RANDELL PART NUMBER
CODE
NO
CODE
CODE
NO
CODE
Fcy
CYCLE MANAGEMENT SETTINGS
-
Fcy
Fcy
CYCLE MANAGEMENT SETTINGS
-
Fcy
Cy1
CYCLE 1 SETTINGS
REFRIGERATOR 35°F SETTING
-
Cy1
Cy3
CYCLE 3 SETTINGS
QUICK CHILL 5 HOUR SETTING
-
Cy3
cyS
CYCLE SETTING
tin
cyS
cyS
CYCLE SETTING
tin
cyS
dbC
DEFROST BEFORE THE CYCLE
No
dbC
dbC
DEFROST BEFORE THE CYCLE
No
dbC
iS1
INSERT PROBE SET POINT FIRST PHASE
32
iS1
iS1
INSERT PROBE SET POINT FIRST PHASE
38
iS1
rS1
ROOM PROBE SET POINT FIRST PHASE
35
rS1
rS1
ROOM PROBE SET POINT FIRST PHASE
2
rS1
Pd1
MAXIMUM TIME FOR FIRST PHASE
OFF
Pd1
Pd1
MAXIMUM TIME FOR FIRST PHASE
2
Pd1
iS2
INSERT PROBE SET POINT SECOND PHASE
32
iS2
iS2
INSERT PROBE SET POINT SECOND PHASE
38
iS2
rS2
ROOM PROBE SET POINT SECOND PHASE
35
rS2
rS2
ROOM PROBE SET POINT SECOND PHASE
0
rS2
Pd2
MAXIMUM TIME FOR SECOND PROBE
OFF
Pd2
Pd2
MAXIMUM TIME FOR SECOND PROBE
2
Pd2
iS3
INSERT PROBE SET POINT THIRD PHASE
32
iS3
iS3
INSERT PROBE SET POINT THIRD PHASE
35
iS3
rS3
ROOM PROBE SET POINT THIRD PHASE
35
rS3
rS3
ROOM PROBE SET POINT THIRD PHASE
20
rS3
Pd3
MAXIMUM TIME FOR THIRD PROBE
OFF
Pd3
Pd3
MAXIMUM TIME FOR THIRD PROBE
1
Pd3
dbH
DEFROST BEFORE HOLDING PHASE
YES
dbH
dbH
DEFROST BEFORE HOLDING PHASE
YES
dbH
Hds
SET POINT FOR HOLDING PHASE
35
Hds
Hds
SET POINT FOR HOLDING PHASE
35
Hds
Cy2
CYCLE 2 SETTINGS
FREEZER -4°F SETTING
-
Cy2
Cy4
CYCLE 4 SETTINGS
RAPID THAW 6 HOUR SETTING
-
Cy4
cyS
CYCLE SETTING
tin
cyS
cyS
CYCLE SETTING
tin
cyS
dbC
DEFROST BEFORE THE CYCLE
No
dbC
dbC
DEFROST BEFORE THE CYCLE
No
dbC
iS1
INSERT PROBE SET POINT FIRST PHASE
0
iS1
iS1
INSERT PROBE SET POINT FIRST PHASE
32
iS1
rS1
ROOM PROBE SET POINT FIRST PHASE
-4
rS1
rS1
ROOM PROBE SET POINT FIRST PHASE
41
rS1
Pd1
MAXIMUM TIME FOR FIRST PHASE
OFF
Pd1
Pd1
MAXIMUM TIME FOR FIRST PHASE
3
Pd1
iS2
INSERT PROBE SET POINT SECOND PHASE
0
iS2
iS2
INSERT PROBE SET POINT SECOND PHASE
32
iS2
rS2
ROOM PROBE SET POINT SECOND PHASE
-4
rS2
rS2
ROOM PROBE SET POINT SECOND PHASE
41
rS2
Pd2
MAXIMUM TIME FOR SECOND PROBE
OFF
Pd2
Pd2
MAXIMUM TIME FOR SECOND PROBE
2
Pd2
iS3
INSERT PROBE SET POINT THIRD PHASE
0
iS3
iS3
INSERT PROBE SET POINT THIRD PHASE
32
iS3
rS3
ROOM PROBE SET POINT THIRD PHASE
-4
rS3
rS3
ROOM PROBE SET POINT THIRD PHASE
38
rS3
Pd3
MAXIMUM TIME FOR THIRD PROBE
OFF
Pd3
Pd3
MAXIMUM TIME FOR THIRD PROBE
1
Pd3
dbH
DEFROST BEFORE HOLDING PHASE
YES
dbH
dbH
DEFROST BEFORE HOLDING PHASE
NO
dbH
Hds
SET POINT FOR HOLDING PHASE
-4
Hds
Hds
SET POINT FOR HOLDING PHASE
35
Hds
Summary of Contents for FX-1
Page 2: ...2 2 2 2 888 994 7636...
Page 14: ...14 14 14 14 888 994 7636 Gasket Sealing Adjustment...
Page 41: ...randellfx com 41 41 41 41 Replacement Parts List FX 1 2N1 SERIES REFRIGERATION SYSTEMS...
Page 44: ...44 44 44 44 888 994 7636 Replacement Parts List FX1 4N1 SERIES REFRIGERATION SYSTEMS...
Page 46: ...46 46 46 46 888 994 7636 Replacement Parts List FX1 4N1 SERIES REFRIGERATION SYSTEMS...
Page 49: ...randellfx com 49 49 49 49 Replacement Parts List FX SERIES OPTIONAL ACCESSORY PARTS...