Control Parameters
Table 1: Preset Parameters
Preset
#
Parameter Name
Displayed
Abbrev.
Default
Range
1
Air Temp Set Point
AtSP
-0
°
F
-20
°
F to +40
°
F
2
Air On/Off Differential
AdiF
2
°
F
1
°
F to 5
°
F
3
Product Temperature
Set Point
PtSP
38
°
F
0
°
F to +40
°
F
4
Product On/Off
Differential
PdiF
2
°
F
1
°
F to 5
°
F
5
Manual Mode Timer
Default
nntd
105
(1:45)
1 to 240 minutes
6
Auto Defrost (after chill
cycle)
AdEF
On
Off/On
7
Defrost Temperature
Set Point
dtSP
42
°
F
32
°
F to 60
°
F
8
Defrost Time Duration
ddur
30
minutes
1 to 60 minutes
9
Daily Defrost Initial
Time
dint
2 (AM)
0 to 23 (hours in 24 hr
format)
10
Daily Defrost
Frequency
dFrq
1 (every
24 hrs.)
0 to 4 defrosts per day
11
Fan Defrost
FdEF
On
Off/On
12
Printer Enable
Prnt
Off
Off/On
13
Printing Filter Option
Pfil
CCon
CCOn/CCCt/ C5nn/5-15
14
Auto Temp Alarm
tALn
Auto
(Auto
start)
Off/On/Auto start
Off/(Alarm)/(Auto Start)
15
Auto Alarm Temp
Value
tALu
60
°
F
40
°
F – 70
°
F
16
Auto Alarm Time
tALt
1
minutes
1 – 20 minutes
17
Low Temp Alarm
LoAL
On
Off/On
Table 2: Clock/Calendar Parameters
RTC
Setting
Displayed
Abbrev.
Default
Range
Time
TinE
12:00
Mode Dependent
Mode
NodE
12hr
12hr/24hr
Ante/Post
Meridiem
A-P
AM
AM/PM (12-hr mode)
N/A (24-hr mode)
Year
YEAr
2002
2000 – 2099
Month
Mth
01
01-12
Date
DAtE
01
Month/Year* Dependent
* L E A P - Y E A R C O R R E C T I O N
Summary of Contents for BC-18-PUB
Page 2: ......
Page 27: ...unifiedbrands net 27 Electrical Diagram...
Page 28: ...28 800 621 8560 Electrical Diagram Control Wiring...
Page 29: ...unifiedbrands net 29 Replacement Parts Blast Chiller...
Page 30: ...30 800 621 8560 Replacement Parts Blast Chiller Control Panel...
Page 31: ...unifiedbrands net 31 Replacement Parts Blast Chiller Door Assembly...
Page 32: ...32 800 621 8560 Replacement Parts Blast Chiller Condensing Unit...
Page 33: ...unifiedbrands net 33 Replacement Parts Blast Chiller Evaporator Coil Assy...