21    

19 

21" Dwr front 

RP FRT9903 

 

 

 

 

19A 

24" Dwr front 

RP FRT9904 

 

 

 

19B 

27" Dwr front 

RP FRT9905 

 

 

 

19C 

27" Dwr front - 3 tier 

RP FRT0117 

 

 

 

20 

21" Dwr frame 

RP FRM0301 

 

 

 

 

20A 

24" Drwr frame 

RP FRM0302 

 

 

 

20B 

27" Dwr frame 

RP FRM0303 

 

 

 

20C 

27" Dwr frame - 3 tier 

RP FRM0117 

 

 

 

20D 

Drawer tracks  (1L&1R) 

RP TRK05SM 

20E 

Dwr handle 

HD HDL130 

20F 

Dwr bearing 

HD BRG210 

20G 

Dwr bearing bolt 

FA SCW6002 

21 

Dwr gasket 11.3 x 18.75 

IN GSK9903 

 

 

 

 

21A 

Dwr gasket 11.3 x 21.75 

IN GSK1041 

 

 

 

21B 

Dwr gasket 11.3 x 24.75 

IN GSK1046 

 

 

 

21C 

Dwr gasket 7.5 x 24.75 

IN GSK1070 

 

 

 

22 

Hinged louver - 12" 

RP LVR0116 

 

 

 

 

 

22A 

Hinged louver - 14" 

RP LVR0117 

 

 

22B 

Hinged louver - 18" 

RP LVR0118 

 

 

 

 

 

23 

Louver magnet 

HD CTH9901 

23A 

Louver magnet strike 

HD STR9901 

24 

louver mount hinge bracket 

RP BRK0109 

25 

Solenoid valve (120v) 

RF SOL9801 

26 

TXV (Rail) 

RF VLV404 

27 

TXV (Base)   

RF VLV414 

 

 

 

 

 

28 

Cap tube w/ drier 144" x .044 

RP CAP022 

 

29 

Power cord (condensing unit) 

EL WIR470 

30 

Hanging thermometer 4" 

HD THR100 

31 

Thermostat (Base) 

HD CNT200 

32 

Thermostat (Rail) 

HD CNT0501 

33 

Low Pressure Switch 

RF CNT700 

34 

Condensing unit(1/3HP Tec.) 

RF CON0003 

 

 

 

34A 

Condensing unit(1/2 HP Cope.) 

RF CON9901 

 

 

 

 

34B 

Condensing unit(5/8 HP Cope.) 

RF CON0101 

 

 

 

 

 

35 

Compressor (AEA2411ZXA) 

RF CMP031P 

 

 

 

35A 

Compressor (AFT18C1E) 

RF CMP9902P 

 

 

 

 

35B 

Compressor (AFT22C1E) 

RF CMP0101P 

 

 

 

 

 

38 

Condenser fan motor 

RF MTR0104 

 

 

 

38A 

Cond. Fan motor w/ blade 

RF ASY0101P 

 

 

 

38B 

Condenser fan motor 

RF MTR0001 

 

 

 

 

38C 

Condenser fan motor 

RF MTR0101P 

 

 

 

 

 

39 

Condenser fan blade 

RF BLD0101 

 

 

 

39A 

Condenser fan blade 

RF FAN0101 

 

 

 

40 

Filter drier 

RF FLT251 

 

40A 

Filter drier 

RF FLT377 

 

 

 

 

 

41 

Evaporator coil assy 

RP CSY0403 

 

41A 

Evaporator coil assy 

RP CSY0404 

 

 

 

 

 

42 

Evap coil mounting bracket 

RP BRK007 

43 

Evaporator coil 

RF COI107 

44 

Evaporator drip pan - plastic 

RP DRP107 

Summary of Contents for 8148N

Page 1: ...f the consignee to inspect the container upon receipt of same and to determine the possibility of any damage including concealed damage Randell suggests that if you are suspicious of damage to make a...

Page 2: ...your recent purchase of Randell food service equipment and welcome to the growing family of satisfied Randell customers Our reputation for superior products is the result of consistent quality crafts...

Page 3: ...esign and specifications without prior notice NOTICE Please read the entire manual carefully before installation If certain recommended procedures are not followed warranty claims will be denied MODEL...

Page 4: ...lation and set up In the event equipment was shipped to a site other than the final installation site Randell will warranty for a period of three months following installation with proof of starting d...

Page 5: ...Randell offers both 1 and 2 year extensions Labor extensions begin at the end of our standard warranty and extend out 9 months to 1 calendar year or 21 months to 2 calendar years from date of purchas...

Page 6: ...Failure to notify Randell before fabrication holds the dealer accountable for all additional charges CANCELLATIONS Orders canceled prior to production scheduling entered into engineering production a...

Page 7: ...eturned goods shipment lacking the return authorization number will be refused all additional freight costs to be borne by the returning party Returned equipment must be shipped in original carton fre...

Page 8: ...nd unit 8148N 48 33 42 9 35 1 27 1 3 115 9 5 15P 16 9 1380 8260N 60 33 42 9 35 2 24 1 3 115 9 5 15P 16 14 8 1380 8268N 68 33 42 9 35 2 27 1 3 115 9 5 15P 16 17 8 1380 8383N 83 33 42 9 35 2 24 1 21 115...

Page 9: ...l at all times during operation If no product is available or necessary fill empty pans with 1 to 2 of water as an insulating barrier Note Even though your 8000N series was designed for heavy use exce...

Page 10: ...hour should be allowed for the unit to cool down 4 Load the product and proceed with food preparation Note Product entering the preparation table must be at 41 F or less EVENING SHUT DOWN PREP RAIL 1...

Page 11: ...dbrands net 11 Unit Operation cont DRAWER REMOVAL AND INSTALLATION To remove and re install individual drawers and drawer tracks please refer to Figure 2 below for proper installation instructions Fig...

Page 12: ...a result of an auxiliary filter will not be covered under warranty NOTE Brush coil in direction of fins normally vertically as to not damage or restrict air from passing through condenser 2 Clean fan...

Page 13: ...R USE HYDROCHLORIC ACID MURIATIC ACID ON STAINLESS STEEL Proper maintenance of equipment is the ultimate necessity in preventing costly repairs By evaluating each unit on a regular schedule you can of...

Page 14: ...14 14 14 14 800 621 8560 Electrical Diagram...

Page 15: ...nser coil dirty 1 Clean coil 2 Condenser fan faulty 2 Service condenser motor 3 Gaskets not sealing 3 Replace gaskets 4 Covers off unit 4 Re apply covers Rail not cold enough base temp OK 1 Temperatur...

Page 16: ...16 16 16 16 800 621 8560 Replacement Parts 8000N Series exploded view...

Page 17: ...unifiedbrands net 17 Replacement Parts 8000N Series exploded view Drawer Assembly...

Page 18: ...18 18 18 18 800 621 8560 Replacement Parts 8000N Series exploded view Mechanical area...

Page 19: ...unifiedbrands net 19 Replacement Parts 8000N Series exploded view Evaporator Coil Assembly...

Page 20: ...ft hand 27 x26 RP DOR0325 x x x 9A Door left hand 24 x26 RP DOR0323 x x x 9B Door left hand 21 x26 RP DOR0321 x x 10 Door gasket 24 5 x24 5 IN GSK1030 x x x 10A Door gasket 21 75 x24 5 IN GSK1025 x x...

Page 21: ...x x 26 TXV Rail RF VLV404 x x x x x x 27 TXV Base RF VLV414 x 28 Cap tube w drier 144 x 044 RP CAP022 x x x x x 29 Power cord condensing unit EL WIR470 x x x x x x 30 Hanging thermometer 4 HD THR100 x...

Page 22: ...er 7 75 RP DIV0106 x 54 Pan Cover Hinges pair RP HNG006 x x x x x x 55 Adapter Bars RP BAR1325 x x x x x x 56 On Off rocker switch base rail EL SWT0502 x x x x x x 57 Panel filler 8148N only RP PNL011...