Installation Diagram
4
Installation Diagram
Fig. 4.1
Safety Precautions
CAUTION
•
This illustration is for explanation purposes
only. The actual shape of your air
condtioner may be slightly different.
Copper lines must be insulated
independently.
•
CAUTION
•
To prevent unnecessary damage to the wall,
use a stud finder to locate studs.
A minimum pipe run of 9.8 ft (3 m) is required
to minimize vibration and excessive noise.
Two of the A, B, and C directions should be
free from obstructions.
•
•
Installation
Diagram
More than 4.7 in (12 см)
More than 4.7 in (12 см)
More than 4.7 in (12 см)
More than 4.7 in
(12 см)
More than 4.7 in
(12 см)
More than
11.8 in (30 см)
More than 78.7 in (200 см)
More than
23.6 in (60 см)
More than 23.6 in
(60 см)
More than
3.9 in (10 см)
More than 5.9 in (15 см)