Preparation For Fastening

Acceptable Base Materials

The gas powered T2 tool is suitable for 

use in the following base materials only:
•  Poured Concrete
•  Structural Steel
•  Concrete Block and Horizontal Joints 

in Brick or Masonry Walls

Never attempt to fasten into any other 

type of material. 

Fastening into other 

materials can cause blindness or other 

serious injury.

Never attempt to fasten into very hard 

or brittle materials such as cast iron, 

tile, glass, or rock of any type. 

These 

materials can shatter, causing the fastener 

and/or base material fragments to fly  

free and cause serious injury to the tool 

operator and others.

Never fasten into any base material that 

does not pass the Center Punch test. 

Failure to assure the suitability of the 

base material can result in serious injury 

to the eyes or other body parts.

Center Punch Test

ALWAYS WEAR SAFETY GOGGLES 

WHEN PERFORMING THIS TEST.
1.  Always check the material being  

fastened into for hardness before 

attempting any fastening operation.

2.  Using a fastener as a center punch, 

strike the fastener against the work 

surface using an average hammer 

blow and check the results.

 

 

Center Punch Test Results

1.  If the fastener point is flattened,  

the material is too hard for a  

powder actuated fastening.

2.  If the fastener penetrates the  

material easily, the material is  

too soft.

3.    If the material cracks or shatters,  

the material is too brittle.

4.  If the fastener makes a small  

indentation into the material, the 

material is suitable for fastening.

SAFETY INSTRUCTIONS 

DANGER

SAFETY INSTRUCTIONS 

DANGER

4

Solid Concrete and 

Precast Concrete

Structural Steel

Solid or Hollow 

Block

Horizontal Joints 

only in Brick Walls

Summary of Contents for T2

Page 1: ...RAMSET T2 TOOL OPERATOR S SAFETY OPERATING INSTRUCTION MANUAL DANGER READ AND OBEY ALL SAFETY AND OPERATING INSTRUCTIONS BEFORE OPERATING TOOL GAS POWERED LOW VELOCITY PISTON TYPE FASTENING TOOL...

Page 2: ...echarge refill or recycle fuel cells Never operate the T2 tool if flammable or explosive materials are nearby Just as no one can merely read a book about driving an automobile and then hope to drive o...

Page 3: ...TION 2 CONTENTS 3 SAFETY INSTRUCTIONS 4 7 FASTENING APPLICATIONS 8 TOOL OPERATING INSTRUCTIONS 9 PARTS SCHEMATIC 10 11 PARTS LIST 12 13 SERVICING TROUBLESHOOTING 14 WARRANTY 15 TABLE OF CONTENTS TABLE...

Page 4: ...ility of the base material can result in serious injury to the eyes or other body parts Center Punch Test ALWAYS WEAR SAFETY GOGGLES WHEN PERFORMING THIS TEST 1 Always check the material being fastene...

Page 5: ...ls be used in the T2 tool Batteries The battery will become discharged even if the tool is not being used Remove the battery from the tool when the tool is not to be used or put it in the no contact p...

Page 6: ...n is not on the battery needs recharged Installing the fuel cell There is a cap located on the rear of the tool handle that covers the fuel cell Twist the cap 1 8 turn clockwise and remove it Insert t...

Page 7: ...r hand on or over the end of the tool to close the tool Never carry the tool with your finger on the trigger Never leave the tool unattended or allow anyone to operate it without first being trained N...

Page 8: ...into the concrete Driving fasteners too close to an edge or too close to each other can cause the concrete edge to fail or fasteners to fly free Fastening to Concrete Block or to Masonry Walls Take c...

Page 9: ...nail strip 6 Place the tool in the spot where you want to make the fastening 7 With the tool in position and perpendicular to the work surface press down on the tool 8 Note that the fan motor is runni...

Page 10: ...RAMSET T2 TOOL SCHEMATIC PARTS SCHEMATIC 10 PARTS SCHEMATIC...

Page 11: ...RAMSET T2 TOOL SCHEMATIC continued PARTS SCHEMATIC 11 PARTS SCHEMATIC...

Page 12: ...D 15 403992 O RING CYLINDER HEAD 16 403167 FAN BLADE 17 B0044A CAGE ASSEMBLY AND BUMPERS 17 B0057 CAGE SCREWS M4 6 18 339010 SHEAR BLOCK KIT CONSIST OF SHEAR BLOCK 2 M5 T NUTS 2 M5 12 SCREWS 19 333180...

Page 13: ...47 333460A FEED ASSEMBLY INCLUDES FUEL FEED ASSEMBLY FEED TUBE 49 333480A FUEL INJECTION ASSEMBLY INCLUDES FUEL FEED ASSEMBLY FUEL FEED TUBE 51 336870 BELT HOOK 53 B0062A HANDLE SCREWS pkg of 5 54 01...

Page 14: ...an is on but the tool does not fire LED is red Battery power is too low Recharge battery LED is green Fuel cell is exhausted Put in new fuel cell Fan stops after the Call your local distributor for se...

Page 15: ...which has been subjected to misuse abuse accidental or intentional damage use with fasteners fuel battery or battery chargers not meeting Ramset specification size or quality improperly maintained rep...

Page 16: ...VISIT OUR WEB SITE AT WWW RAMSET COM OR CALL 800 241 5640 Concrete Fastening Systems Glendale Heights IL 60139 800 RAMSET6 1 800 726 7386 www ramset com Buy with Confidence Buy From Your Authorized D...