RAM 30-30
11
RAMSET
www.ramsetinc.com
DIP SWITCh CONFIGURATION
Dip Switch "A" 1, 2 & 3;
AUTOMATIC TIMER TO CLOSE GATE
‘0’ is “OFF” ‘1’ is “ON”
Switch 1 2 3 Gate Open Duration:
1 1 1
60 seconds
1 1 0
45 seconds
1 0 1
30 seconds
1 0 0
15 seconds
0 1 1
10 seconds
0 1 0
05 seconds
0 0 1
00 seconds
0 0 0
disabled - command required to close
Dip Switch "B" 1; Not in use at this time.
Leave in the ‘Off’ position.
Dip Switch "B" 4,5,6 & 7; Not in use at this time.
Leave in the ‘Off’ position.
Dip Switch “A” 4 - 1/2 HP ERD
Dip switch A4 works with Dip switch B8
DIP A4 B8 Sensitivity
OFF OFF Most Sensitive
ON OFF 1/2 Hp—Medium Sensitivity
OFF ON
3/4 Hp—Medium Sensitivity
ON
ON
Least Sensitive
Dip Switch "B" 2; “PRE WARN”
Used with JP2 “Relay Connections”: pins 7 & 8.
Triggers a relay, for an alarm or light (not included), for 3 sec-
onds before the gate will move in any direction.
Sw.
Function:
ON Triggers the relay on JP2 pins 7 & 8 for 3 seconds.
OFF
Regular working conditions
Dip Switch "B" 3; “CONSTANT WARN”
Used with JP2 “Relay Connections”: pins 7 & 8.
Triggers a relay, for an alarm or light (not included), to be ac-
tive anytime the gate is in motion.
Sw.
Function:
ON Triggers the relay on JP2 pins 7 & 8 while the gate
is moving
OFF
Regular working conditions
Dip Switch “B” 8 - 3/4 HP ERD
Dip switch B8 works with Dip switch A4
DIP A4 B8 Sensitivity
OFF OFF Most Sensitive
ON OFF 1/2 Hp—Medium Sensitivity
OFF ON
3/4 Hp—Medium Sensitivity
ON
ON
Least Sensitive
DIP SWITCH "A"
DIP SWITCH "B"