RAMFAN FlowPath UB20 Series Technical Information Download Page 2

SM-EFATEX Rev E  - Page  1 of 13

WARNING!

These units are intended for Explosive Atmosphere use in accordance with ATEX Directive 

2014/34/EU. It is the user’s responsibility to determine the suitability of this equipment for 

the intended purpose.

CAUTION! THESE FANS ARE NOT INTENDED FOR USE IN MINES SUSCEPTIBLE TO 

FIREDAMP.

Explosion Proof Fan Rated: 

II 2 G Ex db eb IIB T6 Gb

Euramco Safety hereby declares that the equipment listed in this manual conforms to the 

relevant Essential Health and Safety Requirements of the European Machinery Directive and 

standards listed below.

Council of European Communities Directive:

Directive 2014/34/EU.

Standards to which conformity is declared:

See “Declaration of Conformity” 

Category, Group and Zone Classifications

According to ATEX Directive (2014/34/EU)

        

II 2 G Ex db eb IIB T6 Gb

        0539 Demko 09 ATEX 0926969X 

        IECEx UL 13.0062X

Special Conditions for Safe Use:

The unterminated power cable (flying leads) must be terminated by the end user in the field 

according to installation standards, IEC/EN/ABNT NBR IEC 60079-14, to a suitable safe power 

location, or under one apparatus or enclosure in one of the protection concepts for use 

in hazardous locations. Flying leads consist of a brown “Hot” wire, blue “Neutral” wire and 

yellow/green “Ground” wire.

T6 Temperature Classification:

85°C T6 - According to IEC 60079-0 / EN 60079-0 / ABNT NBR IEC 60079-0.

To ensure that there is no risk of ignition due to hot surfaces, the equipment is classified with 

regard to the maximum surface temperature of any part of the equipment while in operation 

based on the ambient temperature of 40°C. Equipment must be selected with a suitable 

temperature classification for the gases and vapors present where the equipment is to be 

installed. Ensure that the maximum surface temperature of any parts of the equipment are 

below the ignition temperature of the explosive atmosphere concerned.

This equipment is intended for use in ambient temperatures ranging between -20°C and 
+40°C.

The letter “X” at the end of the ATEX, IECEx, and INMETRO certificate numbers 

indicate a special condition for safe use. This special condition of safe use refers 

to the fact that the Hazardous Location Fans referenced herein are supplied 

without an AC power plug termination for the power cable.

Summary of Contents for FlowPath UB20 Series

Page 1: ...Portable Ventilators for Hazardous Locations UB20xx EFi120xx EFi75xx EFi150xx Applicable Models The Portable Ventilators described herein are intended for use in Explosive Atmospheres in accordance w...

Page 2: ...IEC 60079 14 to a suitable safe power location or under one apparatus or enclosure in one of the protection concepts for use in hazardous locations Flying leads consist of a brown Hot wire blue Neutr...

Page 3: ...Voltage Frequency Impeller Motor part No UB20xx EF7002 EF8002 115 VAC 50 60 HZ 230 VAC 50 60 HZ Plastic 1933007415 1933007419 EFi75xx EB7201XX EB7201XX 230 115 VAC 50 60 HZ 230 VAC 50 60 HZ Metal 113...

Page 4: ...Classification IP68 Temperature Range 4 F to 212 F Approval PTB 00 ATEX 1063 The power cables are not terminated with power plugs See Special Conditions for safe use The fans are assembled with both...

Page 5: ...lication in a potentially explosive environment the ducting must be 1 Statically Conductive Surface resistance 106 ohms 2 Flexible 3 Reinforced with integrated helical steel wire spaced to prevent duc...

Page 6: ...ompliance with electrical code Keep area clear of rock and debris Keep away from children WARRANTY Positive Pressure Ventilators Turbo Ventilators and portable blowers excluding motor and wear items a...

Page 7: ...rflow also referred to as free air occurs at 0 mm 0 w g The first chart shows 4 performance curves for all four ATEX fans running on 50Hz AC power The second chart show 3 performance curves for three...

Page 8: ...SM EFATEX Rev E Page 7 of 13 Fan Performance Characteristic for Fans Running on 60Hz AC power...

Page 9: ...k Couple Canister with 8 x 25 Duct Antistatic FDT 0815CBB Duct 8 x 15 Antistatic with Belt and Belt FDT 0825CBB Duct 8 x 25 Antistatic with Belt and Belt EF0304X Duct Adapter 8 20cm DC8 Duct Coupler 8...

Page 10: ...TER KIT 8 EZ 16 3 E POWER CABLE 2 EF7019 PULL ROD 9 EF7105AC HOUSING CONDUCTIVE 3 EM F 33 60XPEX EF7002 ATEX MOTOR 10 ST010 STATOR 4 EM F 33 230VXP EF8002 ATEX MOTOR 11 ED0170 MOTOR MOUNTING RING 5 ED...

Page 11: ...cm DUCT ADAPTER KIT 7 EZ 14 3E POWER CABLE 2 EB7018 EFi75xx SWITCH ROD 8 EA7007 ADAPTER CASTING C FACE 3 EZ CAP A027 PUSH CAP 9 EB7201XXHA 12 BLOWER HOUSING ASSY 4 EM F 75 60XPEX MOTOR 10 EZ 312 RWB...

Page 12: ...7 8 6 9 10 11 1 EA7116 16 40 cm DUCT ASSY INLET 7 EZ 312 RWB CORD STRAP 2 EC7018 SWITCH ROD 8 EG8200XXHA HOUSING ASSY 3 EM F1 5 60 50XPEX MOTOR 9 EA7007 ADAPTER CASTING C FACE 4 EA7004 FLANGE 10 BL91...

Page 13: ...7 8 10 11 9 6 1 EA7116 16 40 cm DUCT ASSY INLET 7 EZ 312 RWB CORD STRAP 2 EC7018 SWITCH ROD 8 EG8200XXHA HOUSING ASSY 3 EM F1 5 60 50XPEX MOTOR 9 EA7007 ADAPTER CASTING C FACE 4 EA7004 FLANGE 10 BL91...

Page 14: ...DIAGRAM MOTOR LEADS LINE CORD Ground Screw Yellow Green wire from Motor Cord Black Wire 1 from Motor Cord Black Wire 2 from Motor Cord Ground Screw Yellow Green wire from Power Cord Brown Wire from P...

Reviews: