ANCILLARY SERVICE INFORMATION 

MAINTENANCE  

  Allow the cooker to cool after use before performing any cleaning or maintenance work. Do 

not move the appliance or attempt any maintenance within 30 minutes of cooker being used.  

  Burner ports may be cleaned with either compressed air or pipe cleaner or similar device.  

Any spider’s web formed in the burner inlet (venturi) must be cleared with a pipe cleaner or 
similar length device. Caution: Operation of the burner with a web in the inlet may result in 
leakage and/or ignition of gas at the burner inlet.  

 

  It is also recommended that the hose assembly and regulator inlet fitting seals be checked 

for  damage,  abrasion,  cracking  or  displacement  before  each  use.    Hose  assemblies  may 

harden with age and should be replaced if this occurs.  If a replacement part or assembly is 

required please contact place of purchase or an authorised agent for advice. 

  Periodic service should be performed at intervals not exceeding 6 months by an authorised 

service agent or more often if required 

  Keep the appliance clean regularly by wiping with a damp cloth. 

  Before checking and maintaining the cooker, make sure the main gas valve is turned off. 

  Make sure the burner head(s) is/are clean before using the cooker. Use a steel wire brush to 

clean the burner if it is heavily clogged. If the burner is heavily clogged, do not use the unit. 

Contact your authorised plumber or gas fitter to carry for cleaning and maintenance. Do not 

attempt to remove the burner unit(s) yourself. 

  Check the gas hose regularly for wear or leaks. If any wear or leaks are presents, please 

contact an authorised plumber / gasfitter for repair. 

  Do not touch the burner, trivet, tray etc. immediately after use or when in use. This could 

burn your hand. 

  Clean  the  bowl  after  each  use.  Always  wipe  off  spills,  do  not  leave  spills  to  dry  on  the 

surface of the bowl or burner. 

  Ensure the burner cap is placed correctly and securely on the burner head. 

 

 

CORRECT 

 

WRONG 

 

 

ABNORMAL OPERATION  

You should cease using the appliance and seek service from an authorised agent if any of the 

following are observed during operation of the appliance:  

  Carbon build up on the appliance or pans, 

  Excessive yellow tipping of the burner flame,  

  Flames lifting off the burner ports or flashing back.    

  The  burner  aeration  disc  is  factory  set  for  operation  on  Propane  gas  and  at  the  required 

supply pressure.  Any adjustment of the aeration disc will result in flame abnormality. The 

aeration disc is located 3.0 mm before the mouth of the mixing tube. This 3.0 mm clearance 

must be maintained.    

Summary of Contents for HPA100LPB

Page 1: ...ions in this manual could result in physical injury and or property damage Hazardous fire or explosion may result if instructions are ignored Remove any transit protection Do not use this appliance if it is leaking damaged or does not operate correctly DO NOT MODIFY THIS APPLIANCE The appliance should be installed in accordance with the following AS NZS 5601 1 gas installations part 1 general inst...

Page 2: ... hose Do not use burner near any air opening s into buildings i e windows doorways ventilation ducts etc Use away from flammable materials Leak test all connections before use and after each cylinder refill refer How to Check for Gas Leaks in this manual NEVER check for leaks with a match or open flame An LP cylinder not connected for use in this appliance shall not be stored near this appliance E...

Page 3: ...d be checked regularly and cleared with a pipe cleaner or similar length device Do not attempt to repair the burner yourself FOR YOUR SAFETY WHAT TO DO IF YOU SMELL GAS Turn off gas supply at bottle immediately and extinguish all naked flames Remove the appliance from any potential ignition sources and do not operate any electrical equipment near the appliance e g light switches power points mobil...

Page 4: ...hes power points mobile phones and pagers Do not operate any electrical equipment in the vicinity of a gas leak Contact your licensed gas fitter to repair the leak and re light the appliance NEVER ATTEMPT TO REPAIR THE APPLIANCE YOURSELF IT MUST BE SERVICED AND REPAIRED BY A LICENCED PLUMBER OR GAS FITTER COMPONENTS LIST HPA100LPB Part No Part Name 1 Gas Manifold 2 Burner Bowl 3 Burner Cap 4 Burne...

Page 5: ...in an above ground open air situation with natural ventilation without stagnant area s where gas leakage and products of combustion are rapidly dispersed by wind and natural convection It is important that the ventilation openings of the appliance are not obstructed The appliance should be protected from direct draughts and be positioned or protected against direct penetration by any trickling wat...

Page 6: ...sure that includes an overhead cover and more than two walls the following shall apply One wall that is equivalent to at least 25 of the total wall area is completely open see figure 4 Fig 4 30 or more in total of the remaining wall area is open and unrestricted see figure 5 In case of balconies at least 20 of the total of the side back and front wall areas shall remain open and unrestricted Fig 5...

Page 7: ... flames electric heaters equipment Cylinders must be stored outdoors in a well ventilated area in an upright position and out of the reach of children The cylinder must never be stored under direct sunlight or where temperatures can reach over 50 C Do not store the cylinder near flames pilot lights or other sources of ignition DO NOT SMOKE around the cylinders Any outdoor storage shall comply with...

Page 8: ...PB only surface The use of an adjustable wrench is required CLEARANCE Minimum clearance from high pressure burner to rear or sidewall must be NO LESS THAN 1 000mm and to the ceiling above must be NO LESS than 2 700mm The burner SHALL NOT be installed or used in a position where it could create a fire hazard Maximum vessel sizes For model HPA100LPB 45 cm for model HPA100LPWF 47 cm ASSEMBLY 1 Remove...

Page 9: ...ay now be turned to adjust to the desired flame setting required Re lighting Burner 1 Turn control knob to the OFF position and turn off gas at the cylinder 2 Wait up to 5 minutes before attempting to re light the high pressure burner 3 Repeat steps at point 4 above ADJUSTING THE FLAME 1 Turn the ignition knob counter clockwise for high flame and clockwise for low flame Shutting Down Burner Turn t...

Page 10: ... Make sure the burner head s is are clean before using the cooker Use a steel wire brush to clean the burner if it is heavily clogged If the burner is heavily clogged do not use the unit Contact your authorised plumber or gas fitter to carry for cleaning and maintenance Do not attempt to remove the burner unit s yourself Check the gas hose regularly for wear or leaks If any wear or leaks are prese...

Page 11: ...RDOUS TO ATTEMPT TO FIT OTHER TYPES OF GAS CONTIANERS TROUBLESHOOTING DO NOT MODIFY THIS APPLIANCE Problem Possible Cause Solution No Ignition Gas bottle is empty Main Gas Valve is not turned on Air trapped in the hose Electronic ignition is wet or dirty Replace the gas bottle with sufficient propane gas Turn off the gas valve once and then turn it on fully Repeat the ignition process until all ai...

Page 12: ...al No IAPMO R T Oceana GasMark GMK10051 NOTE Austcrown Pty Ltd and their appointed agents will not be liable in respect of any misuse which is not in accordance with the instructions and precautions specified in this booklet AUSTCROWN PTY LTD 17 Greenaway Street BULLEEN VIC 3105 AUSTRALIA SHOP ONLINE www auscrown com au Follow us on Facebook Watch our product videos on Auscrown Youtube channel SER...