background image

GB010203 

 

 

      

5

 

 

  Do not spray aerosols in the vicinity of this country cooker while it is in operation 

  Do  not  use  this  appliance  where  petroleum  products or  other  liquids  having  flammable  vapours  are  stored  or 

used. 

 

  Do not hang clothing or other flammable material on or near this appliance. 

  Children  and  adults  should  be  alerted  to  the  high  temperatures  of  the  country  cooker  and  its  effect  on 

surrounding surfaces, clothing and skin. 

 

  Children or the elderly should be supervised when near this appliance 

  If  the  country  cooker  fails  to operate correctly,  contact  place  of  purchase  or  their  authorised  agent for  advice 

and service.  DO NOT CONTINUE TO USE THE APPLIANCE and DO NOT ATTEMPT REPAIRS YOURSELF. 

 

OPERATING INSTRUCTIONS 

LIGHTING THE BURNER: 

1.  Before  lighting,  ensure  the  country  cooker  is  on  a  level  non-combustible  surface  outdoors  and  required 

minimum Clearances from combustible surfaces are maintained as follows: at least 250mm from REAR OR 
SIDES and at least 1200mm OVERHEAD. 

2.  Check  the  gas  hose  and  rubber  seal  o

r  ‘O’ ring of regulator inlet fitting for signs of damage, abrasion or 

cracking 

–  PVC hoses may harden with age - replace the hose and regulator assembly if any damage is 

evident.    

3.  Ensure  the  gas  supply  hose  is  connected  to  the  gas  inlet  of  the  country  cooker  and  the  regulator  is 

connected to the LP cylinder and check that both connections are tight 

– refer sections 5 & 6 of assembly 

instructions. 

4.  Turn  on  the  LP  cylinder  valve  in  a  counter  clockwise  direction  and  check  for  gas  leaks  as  previously 

described in section 7 of the assembly instructions. 

5.  Turn  the  appliance  control  valve  counter-clockwise  until  the  lever  is  in  line  with  the  burner  and  light  the 

burner with a long taper or long match. 

6.  Turn the bolt at the left hand side of the  venturi back and forth  until  you get nice blue flame. This step is 

important, as it ensures there is a right mix of air and gas to achieve a blue flame. 

7.  The burner may now be adjusted to the desired flame setting. 

Turn control valve clockwise for low flame or counter-clockwise for high flame. 
 

SHUTTING DOWN THE BURNER: 

1.  Turn  LP  cylinder  gas 

valve  fully  clockwise  to  “OFF”  position.  The  gas  must  always  be  turned  off  at  the 

cylinder to ensure there is no gas flow and that no gas remains in the regulator, hose and appliance during 
non-use/storage.   

2.  Once the flame has gone out, Turn appliance control valve

(s) to “OFF” position, which is at 90

 to the line 

of the burner. 

 

DO  NOT  TOUCH  HOT  SURFACES,  ALLOW  THE  COUNTRY  COOKER  TO  COOL  BEFORE  CLEANING  IF 
NECESSARY. 

 

ANCILLARY SERVICE INFORMATION 

MAINTENANCE 

SERVICE INSTRUCTIONS FOR LISCENSED GAS FITTER OR PLUMBER. 

(a)  Remove all covers and other parts for access to all components. 
(b)  Remove all components for services. 

 

Do not attempt any maintenance within 30 minutes of country cooker being used.  
Burner ports may be cleaned with either compressed air or pipe cleaner or similar device.  

Any spiders’ webs formed in the burner inlet must be cleared with a pipe cleaner or similar length device.   

Caution:  Operation of the burner with a web in the  inlet may result in leakage and/or ignition of gas at the burner 

inlet.   

 

It is also recommended that the hose assembly and regulator inlet fitting seals be checked for damage, abrasion, 
cracking or displacement before each use.  PVC hose assemblies may harden with age and should be replaced if 
this occurs.  If a replacement part or assembly is required please contact place of purchase or an authorised agent 
for advice. 

Summary of Contents for GB01LP

Page 1: ...or D The hose outlet fitting required to ensure compatibly with the inlet connection of this appliances is BSP female threaded nut and 60ºinverted flare THE CORRECT ASSEMBLY MUST BE USED DO NOT USE ADAPTORS The use of any equivalent certified hose regulator assembly compliant with the requirements above is acceptable WARNING Only use the hose assembly supplied with this appliance for connection th...

Page 2: ...e agent WARNING COUNTRY COOKERS ARE PORTABLE APPLIANCES SUITABLE FOR OUTDOOR USE ONLY THEY ARE NOT SUITABLE FOR INSTALLATION DO NOT USE THIS APPLIANCE IN AN ENCLOSED AREA IT IS FOR OUTDOOR USE ONLY IT IS THE OPERATOR S RESPONSIBILITY TO CHECK THE APPLIANCE IS PROPERLY ASSEMBLED AND MAINTAINED DO NOT USE THIS APPLIANCE IF IT HAS DAMAGED OR WORN SEALS DO NOT LAY THE GAS CYLINDER DOWN CYLINDER SHOULD...

Page 3: ...rts Index Refer to FIGURE 1 2 3 below 1 Trivet 2 Screw Washer Nut 3 Leg 4 Burner Head 5 Gas Valves 6 Screw for Gas Valve 7 Bolt and Spring STEP 1 STEP 2 STEP 3 FIGURE 1 GB01LP STEP 1 STEP 2 STEP 3 FIGURE 2 GB02LP STEP 1 STEP 2 STEP 3 FIGURE 3 GB03LP ...

Page 4: ...nected or reconnected or cylinder is refilled To check for gas leaks open the cylinder valve with the appliance gas valves in the OFF position and check for leakage by brushing a solution of detergent and water on to the connection points at the bottle and the appliance If bubbling is evident may take up to 30 seconds to appear this indicates a gas leak is present If disassembling cleaning reassem...

Page 5: ...he lever is in line with the burner and light the burner with a long taper or long match 6 Turn the bolt at the left hand side of the venturi back and forth until you get nice blue flame This step is important as it ensures there is a right mix of air and gas to achieve a blue flame 7 The burner may now be adjusted to the desired flame setting Turn control valve clockwise for low flame or counter ...

Page 6: ...1 mm Nominal Hourly Gas Consumption MJ h 12 2 x 12 3 x 12 Overall dimensions 140mm x 345mm x 269mm 140mm x 345mm x 520mm 140mm x 345mm x 783mm Gas type Propane Gas pressure kPa 2 75 0 05 AGA Certificate No 6327G PROCEDURES FOR GAS LEAKAGE The strong and distinctive odour of gas may make you aware of a gas leak If you suspect a gas leak Immediately turn off the gas supply at the cylinder valve Turn...

Page 7: ......

Reviews: