background image

AUF300

WWW.RAMIAUDIO.COM

Manuel Utilisateur

User’s Manual

A

B

C

CHANNEL

+

+

+

+

SENS

VCA

ON

+

+

+

+

+

L

ATTENUA

TION

R

TIME CTRL

TIME CTRL

 A    

 A or B    

THRESHOLD

THRESHOLD

+

+

+

+

+

+

+

+

R

R

L

L

PHONES

3 Channel Audio Fader



R

L

RMS

PPM

MODE VU 

ON

ON

SENS

SENS

VCA

VCA

OUTPUT: ALL RELEASE

only B 

 A    

CUE INPUTS / OUTPUT

CHANNEL A

CHANNEL B

CHANNEL C

IN / OUT CONTROL

+dB

-dB

+9

+12 +15

+3

+6

-3

-6

-12

-9

O

AUDIO VIDEO PROFESSIONNEL

Autofader 3 voies stéréo

Analog Autofader (3 stereo channels)

Summary of Contents for AUF300

Page 1: ...B A C A o r B T H R E S H O L D T H R E S H O L D R R L L PHONES 3 Channel Audio Fader R L RMS PPM MODE VU ON ON SENS SENS VCA VCA OUTPUT ALL RELEASE o n ly B A CUE INPUTS OUTPUT CHANNEL A CHANNEL B C...

Page 2: ...RAmi AUF 300 2...

Page 3: ...D TH RESH O LD R R L L PHONES 3 Channel Audio Fader R L RMS PPM MODE VU ON ON SENS SENS VCA VCA OUTPUT ALL RELEASE only B A CUE INPUTS OUTPUT CHANNEL A CHANNEL B CHANNEL C IN OUT CONTROL dB dB 9 12 15...

Page 4: ...re du canal A D clenchement du canal B att nuation ou coupure du canal A suivant l ordre de d clenchement ext rieur La voie A peut tre soit totalement coup e soit att nu e suivant la t l commande ext...

Page 5: ...LEFT OUTPUT REMOTE CONTROL INPUT REMOTE RELAY B C INSERTION OUTPUT CUE A RIGHT OUTPUT INTERNAL PROGRAMMATION PROGRAMMATION EXTERNAL RELAY A RELAY B RELAY D RELAY A ON if channel A ON RELAY C ON if cha...

Page 6: ...n 100 0 de la modulation audio Sur potentiom tre multitour cermet variable de 0 4 secondes 4 R glage de l att nuation du canal A lorsque celui ci est ferm L att nuation augmente dans le sens horaire S...

Page 7: ...t en mode auto ou auto manuel Attention ce r glage doit tre assez court pour viter un blanc trop long en fin de message sur le canal B mais pas trop pour viter les remont es intempestives du canal A b...

Page 8: ...gmente dans le sens horaire Sur potentiom tre multitour cermet variable de 0 8 secondes Actif uniquement en mode auto ou auto manuel Attention ce r glage doit tre assez court pour viter un blanc trop...

Page 9: ...te et le calibrage op rationnel quel que soit l tat du canal ouvert ou ferm 20 Switch de s lection et d envoi du canal C vers le bargraph 22 l coute casque 23 et la sortie asym trique E pour la pr cou...

Page 10: ...u bargraph 21 22 23 Remarques Les niveaux affich s par le bargraph sont des niveaux relatifs Le 0 dB de r f rence peut tre choisi par DIP switch internes 0 dBu ou 6 dBu L AUF 300 est livr en position...

Page 11: ...st r o sym trique sur XLR 3 pts femelle Niveau compris entre 10 dBu et 12 dBu Saturation 26 dBu PUSH 1 2 3 1 GND 2 Pt chaud 3 Pt froid A B C D Sortie PRINCIPALE st r o sym trique sur XLR 3 pts m le Ni...

Page 12: ...9 FEMELLE fig F 1 fig F 2 JP1 JP1 B1 C1 JP3 CANAL B CANAL C OFF OFF N C N C OFF ON STRAP STRAP ON OFF N C N C OFF ON STRAP STRAP ON ON ON STRAP STRAP ON OFF N C N C OFF OFF N C N C OFF ON STRAP STRAP...

Page 13: ...15 3 16 4 17 25 13 V Manuel B opto Manuel B opto Manuel C opto Manuel C opto V Manuel B ordre de basculement sur le canal B avec att nuation du canal A Manuel C ordre de basculement sur le canal C av...

Page 14: ...fectu sur le mixage B C on r injecte la modulation directement sur le bus de l AUF 300 sans perturber son fonctionnement normal 1 8 9 15 Masse Pt Chaud Pt Froid 1 2 9 Sortie GAUCHE Masse Pt Chaud Pt F...

Page 15: ...lable 10 dBu 245mV 12 dBu 3 1V R glable 10 dBu 245mV 12 dBu 3 1V XLR 3 pts Fem XLR 3 pts Fem XLR 3 pts Fem XLR 3 pts M le St r o Sym trique St r o Sym trique St r o Sym trique St r o Sym trique Contr...

Page 16: ...otection mais utilisez des quipements d isolation galvanique transformateurs Ne jamais d monter l quipement sans avoir pris la pr caution de d brancher le cordon d alimentation Eviter l exposition de...

Page 17: ...D TH RESH O LD R R L L PHONES 3 Channel Audio Fader R L RMS PPM MODE VU ON ON SENS SENS VCA VCA OUTPUT ALL RELEASE only B A CUE INPUTS OUTPUT CHANNEL A CHANNEL B CHANNEL C IN OUT CONTROL dB dB 9 12 15...

Page 18: ...channel A Release of the channel B fade or cut of the channel A according to the remote order Channel A can be either totally off or fade according to the remote control It allows to cut completely t...

Page 19: ...LEFT OUTPUT REMOTE CONTROL INPUT REMOTE RELAY B C INSERTION OUTPUT CUE A RIGHT OUTPUT INTERNAL PROGRAMMATION PROGRAMMATION EXTERNAL RELAY A RELAY B RELAY D RELAY A ON if channel A ON RELAY C ON if ch...

Page 20: ...ariable from 0 to 4 seconds The time increases clockwise 4 Multi turn cermet potentiometer to reduce the channel A when this one is closed channel B open The reduction increases clockwise Adjustable f...

Page 21: ...annel but not so long in order to avoid inopportune rising up of A channel during the short audio modulation blank on the B channel This multi turn potentiometer 9 is only active in auto or auto manua...

Page 22: ...long blank at the end of the message on the channel C but not so long in order to avoid inopportune rising up of channel B or A during the short audio modulation blank on the channel B or A This multi...

Page 23: ...onitoring and the calibration operational with the B channel open or not 20 Channel C cue switch for bargraph 22 the monitoring headphones 23 and the unbalanced output E for the premonitoring and the...

Page 24: ...s Same signal as displayed on bargraph Note Displayed levels are relative levels The 0 dB reference level can be set by internal switch at 0 dBu or 6dBu which is the most frequently used level in prof...

Page 25: ...put XLR for left channel C Level included from 10 dBu to 12 dBu Clipping at 26 dBu PUSH 1 2 3 A B C D 3 pin male balanced XLR for left main output Nominal level at 6dBu for other levels contact us E S...

Page 26: ...P1 JP1 B1 C1 JP3 CHANNEL B CHANNEL C OFF OFF N C N C OFF ON LINK LINK ON OFF N C N C OFF ON LINK LINK ON ON ON LINK LINK ON OFF N C N C OFF OFF N C N C OFF ON LINK LINK ON JP2 JP2 B2 C2 JP4 JP3 JP4 Ch...

Page 27: ...Manual B opto Manual B opto Manual C opto Manual C opto V Manual B switching on channel B with GPI with fading of channel A fading from 4 dB to 96 dB Manual C switching on channel C with GPI with tota...

Page 28: ...o Noise ratio 91 dB A weighted at nominal level 111 dB A weighted at clipping Bandwidth 7 Hz to 70 kHz 1 dB All Inputs Outputs external remote Inputs and mains supply are RFI protected Power supply 23...

Page 29: ...rs when connected to other equipments never disconnect grounding use insulating transformer on mains Never open the case without disconnecting mains Avoid high temperature exposure Never expose the eq...

Page 30: ...Fax 33 0 1 64 66 20 30 7 Rue Raoul Follereau 77600 BUSSY SAINT GEORGES FRANCE www ramiaudio com Rami se r serve le droit de modifier les sp cifications du produit sans pr avis All specification in th...