21. Install the 

Cylinder

 over the Body’s O-Ring and seat it 

properly onto the 

Bottom Cap

.

22. Install the 

Top

 

Cap

 onto the 

Cylinder

.

• Use care passing the O-Ring.

23. Install Keeper (

11

) into the groove of the Body.

• Make sure the hole aligns with Carriage Bolt (

1c

).

24. Install one Carriage Bolt through the Air Motor and 

through the Keeper.

25. Install Flange Nut (

1d

).

• Do not tighten the Flange Nut at this time.

26. Repeat procedural steps 

23

 - 

25

 for the additional 

Keepers and Carriage Bolts.

CAUTION

Do  not  overtighten  Flange  Nuts  (1d).  Component
damage can occur.

27. Torque each Flange Nut in an alternate pattern from 60 

to 70 inch-pounds (6.8 - 7.9 Nm).

28. Install Screw (

1b

) into the 

Top Cap

.

• Tighten the Screw to 50 inch-pounds (5.6 Nm).

29. "Snap" Cover (

1a

) onto the 

Cylinder

.

30. Screw Shut-Off Valve (

2

) [with thread sealant] into the 

Air Motor Assembly.
• Tighten the Shut-Off Valve securely in the position 

required.

Operation

WARNING

Do not exceed the lowest pressure rating

of any component in the system.

Never point a control valve at any portion of your
body or another person. Lubricant discharged at
high velocity can penetrate the skin and cause
severe injury. Should any fluid appear to puncture
the skin, get medical care immediately.

Ensure all components are in operable condition.
Replace any  suspect parts prior  to operation.
Personal injury can occur. 

  1. Make sure air pressure at the regulator reads zero.

  2. Slowly supply air pressure [recommended minimum of 

25 psi (1.7 Bars)] to the pump’s motor.
• The pump assembly should cycle.

If the pump assembly does not cycle, refer to the 

Troubleshooting Chart 

for details.

With air pressure at zero:

  3. Connect a product hose to the pump’s material outlet. 

• Direct the hose into an appropriate container.

  4. Place the pump in the product to be dispensed.

  5. Slowly supply air pressure to the pump’s motor.

  6. Allow the pump to cycle slowly until the system and 

product is free of air.

If the pump assembly does not prime, refer to the 

Troubleshooting Chart 

for details.

WARNING

Should leakage occur anywhere within the

system,  disconnect air to the motor. Personal
injury can occur.

With air pressure at zero:

  7. Attach a control valve to the outlet hose of the pump.

  8. Slowly supply 35 psi (2.4 Bars] air pressure to the 

pump’s motor.

  9. Operate the control valve into a container.

10. Allow the pump to cycle until the system and product 

is once again free of air.

11. Shut off the control valve.

12. Set the air pressure to 100 psi (6.9 Bar).

13. Visually inspect the pump for external leaks.

• The pump should not cycle.

If the pump does not stall, refer to the 

Troubleshooting Chart 

for details.

14. Check the motor for air leakage.

If the motor leaks, refer to the

 Troubleshooting Chart 

in the

 Air Motor Service Guide 

for details.

1-800-548-1191 - http://www.partdeal.com - [email protected]

Summary of Contents for 339610-1

Page 1: ...s or bulk tanks that have a 2 NPTF bung fitting The required length downtube screws directly into the 1 1 2 NPTF female threads in the valve body As an alternative the pump can also mount to a wall with the use of a wall bracket and be used with an optional suction hose See Table 2 for details Also the pump screws directly onto two different size threaded standpipes 1 1 2 NPTF m or 2 NPTF f Specif...

Page 2: ...SER 339610 1 Low Pressure Transfer Pump Revision 8 06 2 Figure 2 Low Pressure Transfer Pump Model 339610 1 Exploded View 1 800 548 1191 http www partdeal com info partdeal com ...

Page 3: ...0 172190 26 16 7 X171000 7 O Ring 3 8 ID x 1 2 OD 1 319391 2 8 338109 Washer 3 8 ID x 3 4 OD 1 320531 13 9 X171003 10 O Ring 2 3 4 ID x 3 OD 1 Pack of Ten 10 323474 17 10 339971 Body Pump 1 338109 8 11 339412 Keeper 4 338259 23 12 X171000 105 O Ring 3 ID x 3 1 8 OD 2 Pack of Ten 10 338271 21 13 320531 Bushing 3 4 NPTF m x 1 2 NPTF f 1 338272 22 14 Seal 1 2 ID x 3 4 OD 1 338339 2 27 15 339976 Beari...

Page 4: ...c feet liters per minute right Y axis and to material discharge pressure in psi Bars left Y axis Extension Description Drum Tank 16 Gallon 55 Gallon 250 Gallon Bench Top 275 Gallon Obround V Cut 338147 3 338147 4 338147 8 338147 9 Threaded at both ends 338246 3 338246 4 338246 8 338246 5 NOTE For use with low level cut off valve part number 321206 Additional Accessories Low Level Cut Off Valve 321...

Page 5: ...Top Cap 4 Remove Nuts 1d that secure the Body to Air Motor Assembly 1 5 Remove Bolts 1c from the Top Cap Remove Keepers 11 from the Body 6 Remove the Top Cap from the Cylinder CAUTION Remove the Cylinder with care Damage to Quad Ring 6 and or O Ring 9 can occur 7 With a side to side motion pull the Cylinder from the Body and Air Piston 5 8 Remove O Ring 9 from the Body 9 Remove the Bottom Cap from...

Page 6: ...uid Piston flush with the bottom of the Body Valve Body Assembly 24 Unscrew Valve Body 28 from Cylinder 25 25 Remove O Ring 12 Stop 26 and Ball 27 from the Valve Body Clean and Inspect 1 Clean all metal parts in cleaning solvent The solvent should be environmentally safe 2 Inspect all parts for wear and or damage Replace as necessary 3 Inspect Air Piston 5 and Fluid Piston 21 for fatigue cracks Re...

Page 7: ...4 Install Ball 27 and Stop 26 into the Valve Body Make sure the Stop seats fully into the groove 15 Screw the Valve Body assembly into the Cylinder Use care passing the O Ring 16 Clamp the Valve Body securely in a soft jaw vise 17 Tighten the Pump Body securely into the Cylinder and at the same time the Cylinder onto the Valve Body Use Bushing 13 as leverage Attach Air Motor to Pump Tube 18 Clamp ...

Page 8: ...ion Replace any suspect parts prior to operation Personal injury can occur 1 Make sure air pressure at the regulator reads zero 2 Slowly supply air pressure recommended minimum of 25 psi 1 7 Bars to the pump s motor The pump assembly should cycle If the pump assembly does not cycle refer to the Troubleshooting Chart for details With air pressure at zero 3 Connect a product hose to the pump s mater...

Page 9: ...roduct leakage visible at top of Cylinder 25 1 Cylinder 25 not sufficiently tight 2 Damaged O Ring 12 1 Tighten Cylinder 25 into Pump Body 10 2 Replace O Ring 11 Product leakage visible at bottom of Cylinder 25 1 Cylinder 25 not sufficiently tight 2 Damaged O Ring 12 1 Tighten Cylinder 25 into Valve Body 28 2 Replace O Ring 12 Air leakage at weep hole in Pump Body 10 Damaged Seal 14 Replace Seal 1...

Page 10: ...SER 339610 1 Low Pressure Transfer Pump Revision 8 06 10 1 800 548 1191 http www partdeal com info partdeal com ...

Reviews: