background image

MACDONALD INDUSTRIES LIMITED  

INSTALLATION INSTRUCTIONS

    

www.macdonaldindustries.co.nz    

1

RA-FS10

INDIVIDUAL ELECTRONIC  

URINAL SENSOR

119

11

0

23

7

16.5

74

110

G 1/2”

130

13

0

126

Summary of Contents for RA-FS10

Page 1: ...MACDONALD INDUSTRIES LIMITED INSTALLATION INSTRUCTIONS www macdonaldindustries co nz 1 RA FS10 INDIVIDUAL ELECTRONIC URINAL SENSOR 119 110 237 16 5 74 110 G 1 2 130 130 126...

Page 2: ...The battery powered model uses four AA batteries with average consumption of 0 2mW under static and can be used for 2 years based on 4000 cycles per month Intelligent The sensor is equipped with Fuzzy...

Page 3: ...www macdonaldindustries co nz 3 suction cup MACDONALD INDUSTRIES LIMITED INSTALLATION INSTRUCTIONS...

Page 4: ...average 4000 flushing cycles per month Sensing distance Factory set valve at 65cm adjustable Pre flush There is no pre flush when the time interval of usage is less than 1 minute Water inlet thread E...

Page 5: ...omatically adjusts flush volume according to usage duration When the interval between uses is normal frequency and the duration of use is short the flushometer will deliver the normal flush volume abo...

Page 6: ...c components Please note the following cautions CLEANING AND MAINTENANCE 1 The sensor plate can be cleaned by soft rag with neutral liquid detergent 2 Do not use eradicator abrasive powder or oil acid...

Page 7: ...there might be sand rust and other impurities that will influence life of solenoid valve Hence always clean the supply pipe before installation MACDONALD INDUSTRIES LIMITED INSTALLATION INSTRUCTIONS...

Page 8: ...8 www macdonaldindustries co nz...

Page 9: ...suction cup Use suction cup to remove face plate suction cup Use suction cup to remove face plate suction cup Use suction cup to remove face plate suction cup Use suction cup to remove face plate MAC...

Page 10: ...e adjustment When there is too little or no water flushing the urinal follow steps 2 and 3 on Page 9 to remove cover and outer box Using a flat screw driver rotate the adjustor screw clockwise for les...

Page 11: ...ose the valve M10 Hex wrench Follow steps 2 3 on Page 9 to remove face plate and outer box Turn adjusting screw clockwise to close the valve M10 Hex wrench Follow steps 2 3 on Page 9 to remove face pl...

Page 12: ...ing model falling off black wire Re connect the black wire and sense for 10 seconds Reference page 8 Water pressure out of operating range Adjust the water pressure to operating range Water is dirty a...