15 (19)
ENGLISH
Piping, ventilation
The outgoing pipe of the property's BDT pipeline is connected to the incoming
connection of BioBox M (D75 mm).
If the diameter of the property's sewer pipe is 110 mm, an extension piece is
used. Outgoing pipe from BioBox M is connected to the outgoing connection
(D75 mm) and it is connected to the pipeline (D75 (or
D100; needed extension piece)) which is led into a ditch via a sampling well
or filtered inside the soil with an infiltration well (if possibility of sampling is
needed).
If there is pipeline ventilation to the roof (1) BioBox M is ventilated to the roof.
If not, BioBox M has a ventilation connection between the house and the
device (2).
Also incoming air to BioBox M system is needed from the end of the pipeline
(open ditch) or from the infiltration to the ground (3).
Content of the delivery, accessories
Installation posibilities
Use, generally
Controll, service, to clean the filters
Raita
BioBio M
MANUAL - INSTALLATION
(3)
(3)