is within limit standard. 

 

LOF alarm can result in LAL indicator flicking or ON, this means E1 signal is out of frame. 

If the device works in transparent mode, there is no LOF alarm. 

Please chick if interface impedance switch is set correctly. 

Please check if bit error rate is within limit standard by bit error rate tester. 

If your E1 link has equipments of other brands, there may be a few LAL flicking alarms 

when the converter is just powered on, this is normal. Please wait for a while, and the 

alarm will disappear. If LAL is flicking for a long time, there must be something wrong with 

the link. 

CRC alarm means there is severe bit error in E1 link. 

In transparent mode, there is no CRC alarm. 

CRC alarms may accompany with LOS or AIS, please check if bit error rate is within limit 

standard with bit error rate tester. 

If the suddenly appeared CRC alarms make LAL indicator flicking, which may result in 

network disconnecting, basically this is caused by initializing link process when the 

equipment is just reset. In this case, large traffic should be paused for a while, and the link 

will recover in 10~30 seconds automatically.   

If CRC checkup optional switch---- 7

th

 bit of SWS is ON (CRC disabled), then this alarm 

indicator would not be caused by CRC. 

5

 RAL  ON 

Remote alarm, this means there is something wrong with remote end device of receiving 

direction, please check the link between TX and RX. 

6

 Severe packets loss 

If you need to set the converter in E1 fractional mode (refer to the definition of 1

st

 bit of 

SW1), there must be two interconnected equipments in both sides, one in master clock 

mode and the other in slave clock mode. 

 

 

 

Summary of Contents for RC906-FXE1-M

Page 1: ...RC906 916 FXE1 Fast Ethernet E1 Converter USER MANUAL Raisecom Technology Co Ltd 03 2005...

Page 2: ...aging it is not allowed that the optical power of transceiver s output interface is higher than that of RC906 916 FXE1 RC906 916 FXE1 is an integrated device which has precise elements please avoid vi...

Page 3: ...rking environment 6 4 How to use 7 4 1 Front panel introduction 7 4 1 1 Definitions of indicators 7 4 1 2 Definitions of interface 8 4 2 Instructions of DIP switches setting 8 4 2 1 SW1 switch indicat...

Page 4: ...lled in the chassis for Raisecom only of 16 slots 3U or 4 slots and it also can be used as desktop device when installed in single slot chassis 2 2 Main features z Provide one channel 100M full duplex...

Page 5: ...d Converter type Optical interface Wavelength nm Media converter type RC906 FXE1 M DSC 1310 RC111 FE M RC906 FXE1 S1 DSC 1310 RC111 FE S1 RC906 FXE1 S2 DSC 1310 RC111 FE S2 RC906 FXE1 S3 DSC 1550 DFB...

Page 6: ...unctionalities Complete link alarm indicator Fault Pass Through and intelligent auto reset functions Note if there is some equipment PCM device or DXC device for example that requires modifying the ti...

Page 7: ...SC APC 1550 5 0 32 10 50 0 5 3 4 Network management Software of network management is optional and the functions are as follows Report to controlling computer the 4 level E1 link alarms Local fraction...

Page 8: ...F loss of frame or AIS up stream alarm indication signal or CRC cyclic redundancy check In E1 transparent mode this indicator only indicates LOF loss of frame or AIS up stream alarm indication signal...

Page 9: ...of 75 is by default It is required to pull back the shielding cover at the same time when plug out wire cable Ethernet optical interface The following conditions must be satisfied when connecting to...

Page 10: ...Pass Through switch ON means to enable Fault Pass Through When there are LOS LOF AIS CRC RAL alarms which may lead to Ethernet interface failure it will report to controlling computer Ethernet interfa...

Page 11: ...emote network management function ON means enable OFF mean disable by default 2ed bit local or remote device optional switch ON means local device OFF means remote device by default This bit is only e...

Page 12: ...448K 0 1 0 0 0 8 64K 512K 0 1 0 0 1 9 64K 576K 0 1 0 1 0 10 64K 640K 0 1 0 1 1 11 64K 704K 0 1 1 0 0 12 64K 768K 0 1 1 0 1 13 64K 832K 0 1 1 1 0 14 64K 896K 0 1 1 1 1 15 64K 960K 1 0 0 0 0 16 64K 102...

Page 13: ...mode OFF means PCM31 mode also called FAS only mode default mode This bit of Dip switch of two inter operated interface converters should be the same otherwise the equipment will work abnormally 7th b...

Page 14: ...E1 link and for the sake of device interface safety please connect E1 link before device powered on E1 interface should avoid hot swap 4 2 6 SW4 switch indication SW4 is factory default set and can no...

Page 15: ...Raisecom Technology Co Ltd 14...

Page 16: ...mode interface of RC916 FXE1 S1 should be single mode and the connector should be SC PC Optical medium of single mode interface of RC916 FXE1 S2 should be single mode and the connector should be SC A...

Page 17: ...Wave length nm Optical transceiver type RC906 FXE1 M DSC 1310 RC111 FE M RC906 FXE1 S1 DSC 1310 RC111 FE S1 RC906 FXE1 S2 DSC 1310 RC111 FE S2 RC906 FXE1 S3 DSC 1550 DFB RC111 FE S3 RC916 FXE1 S1 SC...

Page 18: ...dicator means signal loss or up stream AIS alarm If device work in fractional mode LAL means one of the following alarms LOS loss of signal LOF loss of frame AIS up stream alarm indication signal and...

Page 19: ...rms may accompany with LOS or AIS please check if bit error rate is within limit standard with bit error rate tester If the suddenly appeared CRC alarms make LAL indicator flicking which may result in...

Page 20: ...Raisecom Technology Co Ltd 19 2005 Raisecom Technology Co Ltd All trademarks are the property of their respective owners Technical information may be subject to change without prior notification...

Reviews: