Page 1: ...www raisecom com RC552 FE A User Manual May 2006 ...

Page 2: ...age without the prior written consent of Raisecom Technology Co Ltd The information contained in this document is subject to change without notice Copyright Notices Copyright 2006 Raisecom All rights reserved No part of this publication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in ...

Page 3: ...82885200 86 10 82884411 World Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL http www raisecom com Feedback Comments and questions about how the NView iEMS system software works are welcomed Please review the FAQ in the related manual and if your question is not covered send email by using the following web page http www raisecom co...

Page 4: ... RC552 FE A 12 4 3 THE INDICATORS OF 16 SLOT CHASSIS 12 CHAPTER 6 DEVICE SETUP 13 5 1 COPPER INTERFACE CONFIGURATION DIP SWITCH SW20 13 5 2 FUNCTION CONFIGURATION DIP SWITCH SW21 13 5 3 FIBER INTERFACE CONFIGURATION DIP SWITCH SW22 14 CHAPTER 7 NETWORK MANAGEMENT FEATURES 15 6 1 REVIEW THE MODULE 15 6 2 CONFIGURE THE MODULE 15 6 3 LOOPBACK TEST 16 6 4 RESET THE MODULE 16 CHAPTER 8 CONFIGURE AND MA...

Page 5: ...ditions of optical transmitter module and receiver module YD T1017 1999 Network node interface for the Synchronous Digital Hierarchy SDH YD T1022 1999 Requirement of synchronous digital hierarchy SDH equipment function YD T1078 2000 SDH Transmission Network Technique Requirements Interworking of Network Protection Architectures YD T1111 1 2001 Technical Requirements of SDH Optical Transmitter Opti...

Page 6: ...constant bit rate synchronous digital paths G 829 Error performance events for SDH multiplex and regenerator sections G 831 Management capabilities of transport networks based on the synchronous digital hierarchy SDH G 841 Types and characteristics of SDH network protection architectures G 842 Interworking of SDH network protection architectures G 957 Optical interfaces for equipments and systems ...

Page 7: ...RC series media converters and also can be inserted into single slot chassis to act as a standalone device When deployed with remote network management RC552 FE A has two working modes Master and Slave The module at central office shall work at Master mode while the module at customer premise shall work at Slave mode The Master module will originate network management and manage the Slave module W...

Page 8: ...gurable Auto configurable Yes S1 DSC 1310 15 8 31 8 0 25 0 5 Auto configurable Auto configurable Yes S2 DSC 1310 5 0 35 3 10 60 0 5 Auto configurable Auto configurable Yes S3 DSC 1550 DFB 5 0 35 3 15 120 0 25 Auto configurable Auto configurable Yes SS13 SC 1310 1550 15 8 31 8 0 25 0 5 Auto configurable Auto configurable Yes SS15 SC 1550 1310 11 5 31 5 0 25 0 5 Auto configurable Auto configurable Y...

Page 9: ...interface make sure the two media converters are using 1310nm and 1550nm transmit wavelengths respectively For example media converter A transmits at 1310nm and receives at 1550nm then media converter B transmits at 1550nm and receives at 1310nm 2 Matching the speed of optical interface They shall have the same speed 3 Matching the optical power 4 Compliant with IEEE802 3 2000 standard 3 4 Back to...

Page 10: ...rface card Crossover straight through 2 When the UTP interface is at manual configuration status auto MDI MDIX function is disabled and the following connecting rules must be followed Media converter Other Ethernet Device UTP Interface Media converter Switch Straight through Media converter HUB Straight through Media converter Router Crossover Media converter Network interface card Crossover 19 标准...

Page 11: ...Page 11 of 25 3 8 Eligible Power Supply AC 220V 50Hz DC 48V ...

Page 12: ...ent is detected OFF no remote OAM capable equipment is detected Copper link signal action LNK ACT ON copper link is normal OFF copper link failure FLASHING electrical signals are transmiited received Copper link speed 100M ON copper link speed is 100M OFF copper link speed is 10M Copper Duplex mode collision FDX ON copper link is in full duplex mode OFF copper link is in half duplex mode FLASHING ...

Page 13: ...half duplex mode 3 Duplex mode configuration OFF Manually set to full duplex mode if auto negotiation fails work at full duplex mode 4 Reserved Note 1 if 1st bit of SW20 is set to OFF 2nd bit will be invalid Note 2 the default status of SW20 is all OFF 5 2 Function Configuration DIP switch SW21 SW21 is an 8 bit DIP switch including MASTER SLAVE reserved reserved reserved ALS fiber interface to cop...

Page 14: ...e fiber interface to copper interface fault propagation function ON If no electrical signal is detected shut down local fiber interface Note this function only takes effect when OAM is disabled or the device cannot be remotely managed 8 Copper interface to fiber interface fault propagation disable enable OFF Disable copper interface to fiber interface fault propagation function Note 1 by default t...

Page 15: ... finish Configurable 10 Fiber interface outside loopback Start finish Configurable 11 Loopback parameter Exchange MAC address non exchange MAC address Configurable 12 Fiber interface to copper interface fault propagation Enable disable Configurable 13 Copper interface to fiber interface fault propagation Enable disable Configurable 14 Fiber interface ALS Enable disable Configurable 15 Copper inter...

Page 16: ...Packets sent from CO copper interface will be looped inside CO module and received discard by CO copper interface Both network management system and module command line interface can enable or disable loopback test When enabling loopback test and assembling loop circuit customers can connect test equipment to module interfaces and monitor the circuit After test disable loopback test and disassembl...

Page 17: ... can manage the module through connecting a VT100 terminal or a PC or a workstation with terminal simulating program to the console port of RC552 FE A This method is especially suitable for the following situation The network is not stable or no network management The network management program does not have direct network connection Fault diagnostics Log on to RC552 FE A module RC552 FE A console...

Page 18: ...upper level menu from current sub menu In order to operate in console interface the menu options shall be chosen by figures 7 2 2 Display the Module Status Choose 1 in main menu to enter module fiber interface and copper interface status display menu Sub menu displays interface status and MIB information 7 2 3 Configure the Module Loopback Choose 2 in main menu to enter loopback setting interface ...

Page 19: ...odule copper interface CO module inside loopback Packets sent from CO copper interface will be looped inside CO module and received discard by CO copper interface Note 1 when RC552 FE A is working under SLAVE mode only remote module inside loopback and remote module outside loopback can be performed when working under MASTER mode all CO module inside loopback CO module outside loopback and remote ...

Page 20: ...face to fiber interface fault propagation is enabled and no electrical signal is detected shut down local copper interface Tp Fx copper interface to fiber interface fault propagation when enabled and no local electrical receiving signal is detected shut down local fiber interface Note that this function only takes effect when remote OAM is disabled or remote module is unmanageable Because if remot...

Page 21: ...AP of FPGA fails and the firmware file in U35 flash memory is broken the firmware file in U34 flash memory will be used to start FPGA Choose 2 in sub menu to download FPGA firmware file from PC console to U35 flash memory Normally after applying power supply the firmware file in U35 flash memory will be used to boot FPGA However if the file in U35 flash is broken the file in U34 flash will be used...

Page 22: ...4 to transfer and save the firmware file to remote SLAVE module U35 flash Reboot remote module FPGA to finish remote upgrade 3 Finally choose 3 to reboot MASTER FPGA and finish local upgrade 4 During FPGA firmware upgrade subscribers traffic will be interrupted because of FPGA reboot After upgrade the modules will be working normally 7 2 6 Exit the Console Choose 5 in main menu to exit the console...

Page 23: ...ve device to originate OAM discovery process After OAM discovery success it is able to implement other OAM functions Note RC552 FE A supported max OAMPDU is 1024 Bytes 8 3 MIB Variable Reply RC552 FE A provided switching microchip has MIB information reply function which is a sub collection of standard EMIB RC552 FE A only answers active device s MIB information request When requested variables ar...

Page 24: ...ter changing the agent RC552 FE A management display becomes slow Answer on conditions that RC552 FE A status doesn t change it reports its status to the agent every 120 seconds Thus after changing the agent the status report looks slow averagely 60 seconds 7 The copper interface is configured by DIP switch but settings are changed after applying power supply Answer such situation may take place i...