RC3000-15 (P100R001) Hardware Description
13 Cables
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
195
Parameter
Description
Insulated sheath
70 mm, 105 mm, or customized. The letter D in cable model
indicates the length, which can be customized. For example, if
the customer requires a 2-m cable, you can name it PIL-ground
cable-Φ4-200mm/RoHS.
Table 13-5 lists technical specifications of the OT terminal.
Table 13-5
Technical specifications of the OT terminal
Parameter
Description
Model
Ground pressed round terminal (M4)/RoHS
Specifications
4.3 soldering lug
Inner diameter: 4 mm
Outer diameter: ≤ 8 mm
Diameter of the stripped wire: 2.1 mm
Thickness of the soldering lug: ≥ 0.6 mm
Cross-sectional area of
the conducting wire
16–15 AWG (1.2–1.5 mm
2
)
13.4 Configuration cable
13.4.1 Introduction
The configuration cable is used to connect the Console interface on the RC3000-15 to the RS-
232 serial interface on the maintenance console and transmit configuration data. You can
debug and maintain the RC3000-15 locally through the maintenance console.
The configuration cable is a 4-wire unshielded cable. Connectors at both ends of the
configuration cable are as below:
RJ45 connector: connected to the Console interface
DB9 female interface: connected to the serial interface on the maintenance console
Appearance
Figure 13-6 shows the appearance of the configuration cable.