Raisecom
iTN8600-I (A) Product Description
4 Technical specifications
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
29
Table 4-7 lists concentration requirements for the mechanical active substance in transport.
Table 4-7
Concentration requirements for the mechanical active substance in transport
Mechanical active substance
Concentration
Suspending dust (mg/m³
)
Droppable dust (mg/m²
·h)
≤ 3.0
Grit (mg/m³
)
≤ 100
Table 4-8 lists concentration requirements for the chemical active substance in transport.
Table 4-8
Concentration requirements for the chemical active substance in transport
Chemical active substance
Concentration
SO
2
(mg/m³
)
≤ 0.30
H
2
S (mg/m³
)
≤ 0.10
NO
2
(mg/m³
)
≤ 0.50
NH
3
(mg/m³
)
≤ 1.00
Cl
2
(mg/m³
)
≤ 0.10
HCl (mg/m³
)
≤ 0.10
HF (mg/m³
)
≤ 0.01
O
3
(mg/m³
)
≤ 0.05
4.6.3 Operating environment
Climatic environment
The temperature and humidity are measured 1.5 m above the ground and 0.4 m in
front of the device.
Table 4-9 lists climatic environmental requirements during operation.
Table 4-9
Climatic environmental requirements during operation
Parameter
Description
Altitude (m)
≤ 3000
Air pressure (kPa)
86–106
Temperature (°C) (altitude: 0–1800 m)
-5 to +50