iTN2100 (P100R002) Hardware Description
13 EOP cards
Raisecom Technology Co., Ltd.
113
Interface
Status
Description
ACT
Green
Primary/Slave LED for the aggregation card
In dual-card protection mode:
Green: the card is primary.
Off: the card is slave.
In non-protection mode: it is Green.
LOF (1–4)
Red
LOF alarm LED
Red: input LOF alarms are generated on optical
interfaces 1, 2, 3, and 4.
Off: no input LOF alarms are generated on optical
interfaces 1, 2, 3, and 4.
LOS (1–4)
Red
LOS alarm LED
Red: input LOS alarms are generated on optical
interfaces 1, 2, 3, and 4.
Off: no input LOS alarms are generated on optical
interfaces 1, 2, 3, and 4.
13.9.5 DIP switches
Table 13-45 lists configurations of the DIP switch on the iTN2100-EOT-GESTM4.
Table 13-45
Configurations of the DIP switch on the iTN2100-EOT-GESTM4
SW1
Function
Status
Description
No.
Bit1
Set the optical
interface rate.
ON
Set the rate of the first optical interface to STM-4;
others become invalid.
OFF
Set the rate of the four optical interface to STM-1.
Bit2
Set the valid
SDH interface.
ON
The SDN interface on the backplane takes effect.
Meanwhile, the SDH interface on the front panel is
invalid.
OFF
The SDN interface on the front panel takes effect.
Meanwhile, the SDH interface on the backplane is
invalid.
By default, Bit1 is OFF.
When configuring the SDH interface on the backplane to take effect through Bit2, you
need to set Bit1 to ON.