Page 2: ...ication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in Writing from Raisecom Technology Co Ltd is the trademark of Raisecom Technology Co Ltd All other trademarks and trade names mentioned in this document are the property of their respective holders The information in this document ...

Page 3: ...e following table lists manuals and their contents related to the ISCOM5508 Name Description ISCOM5508 B Hardware Description This guide mainly introduces product overview components fiber and cables pluggable modules lookup table of LEDs and lookup table of weight and power consumption ISCOM5508 B Configuration Guide This guide mainly introduces basic configuration data service configuration mult...

Page 4: ...l information to emphasize or supplement important points of the main text Indicate a tip that may help you solve a problem or save time General conventions Convention Description Times New Roman Normal paragraphs are in Times New Roman Arial Paragraphs in Warning Caution Notes and Tip are in Arial Boldface Names of files directories folders and users are in boldface For example log in as user roo...

Page 5: ... 2 1 3 Hardware information label 7 2 2 MCC EPSC 8 2 2 1 Introduction 8 2 2 2 Panel and slots 8 2 2 3 Interfaces 8 2 2 4 LEDs 10 2 2 5 Technical specifications 10 2 3 4 EPON interface sub card EP4B 11 2 3 1 Introduction 11 2 3 2 Panel and slots 11 2 3 3 Interfaces 11 2 3 4 LEDs 12 2 3 5 Technical specifications 12 2 4 4 GE interface sub card GE4B 12 2 4 1 Introduction 12 2 4 2 Panel and slots 12 2...

Page 6: ...es 20 3 1 Fiber 20 3 1 1 Introduction 20 3 1 2 Connector 21 3 1 3 Wiring scheme 22 3 2 Ethernet cable 23 3 2 1 Introduction 23 3 2 2 Appearance 23 3 2 3 Technical specifications 23 3 3 Configuration cable 26 3 3 1 Introduction 26 3 3 2 Appearance 26 3 3 3 Technical specifications 27 3 4 DC power cable 28 3 4 1 Introduction 28 3 4 2 Appearance 28 3 4 3 Technical specifications 29 3 5 AC power cable...

Page 7: ...35 4 2 1000 Mbit s SFP electrical module 36 4 2 1 Functions and appearance 36 4 2 2 Techinical specifications 36 4 3 PON SFP optical module 37 4 3 1 Functions and appearance 37 4 3 2 Label 37 4 3 3 Technical specifications 38 5 Lookup table of LEDs 39 6 Lookup table of weight and power consumption 41 7 Appendix 43 7 1 Terms 43 7 2 Acronyms and abbreviations 44 ...

Page 8: ...card 11 Figure 2 9 Panel of the GE4B sub card 13 Figure 2 10 Panel of the RPA1101 power module 15 Figure 2 11 Panel of the RPD1101 power module 17 Figure 2 12 Panel of the FANS306 module 19 Figure 3 1 LC PC fiber connector 21 Figure 3 2 SC PC fiber connector 22 Figure 3 3 Ethernet cable 23 Figure 3 4 Wiring of the straight through cable wiring 24 Figure 3 5 Wiring of the 100 Mbit s crossover cable...

Page 9: ...o Ltd 7 Figure 3 13 OT terminal 32 Figure 4 1 1000 Mbit s SFP optical module 34 Figure 4 2 Label of the 1000 Mbit s SFP optical module 35 Figure 4 3 1000 Mbit s SFP electrical module 36 Figure 4 4 PON SFP optical module 37 Figure 4 5 Label of the PON SFP optical module 37 ...

Page 10: ...he EP4B sub card 12 Table 2 11 Technical specifications of the EP4B sub card 12 Table 2 12 Interfaces on the GE4B sub card 13 Table 2 13 Parameters of the 1000BASE X SFP optical interface 13 Table 2 14 LEDs on the GE4B sub card 14 Table 2 15 Technical specifications of the GE4B sub card 14 Table 2 16 Interface on the RPA1101 power module 15 Table 2 17 LEDs on the RPA1101 power module 16 Table 2 18...

Page 11: ...ical specifications of the European standard AC power cable 30 Table 3 11 Technical specifications of the American standard AC power cable 30 Table 3 12 Technical specifications of the grounding cable 32 Table 3 13 Technical specifications of the OT terminal 33 Table 4 1 Model of the 1000 Mbit s SFP optical module 35 Table 4 2 Technical specifications of the 1000BASE X SFP optical module 35 Table ...

Page 12: ...equirements for optical fiber access Work with the Optical Network Unit ONU as the OLT in EPON to construct the low cost high bandwidth and long distance access network thus addressing problems of small and medium scale fiber access Meet Fiber To The Home FTTH and Fiber To The Building FTTB networking requirements Support automatically collecting information about the power grid and meet requireme...

Page 13: ...40 mm Width 266 mm Depth 44 mm Height without brackets Figure 1 1 shows the appearance of the ISCOM5508 chassis Figure 1 1 Appearance of the ISCOM5508 chassis 1 2 2 Distribution of slots The ISCOM5508 provides the following 6 slots 1 Main Control Card MCC slot slot 1 2 extended sub card slots slot 2 and slot 3 1 fan module slot slot 6 2 power module slots slot 4 and slot 5 Figure 1 2 shows distrib...

Page 14: ...ut brackets Standard configuration Weight 5 51 kg Power consumption 40 W Full configuration Weight 6 24 kg Power consumption 63 W DC power Rated voltage 48 VDC Voltage range 38 to 72 VDC AC power Rated voltage 110 220 VAC Voltage range 100 240 VAC Frequency 50 60 Hz Standard configuration chassis MCC EPSC 2 power modules and 1 fan module Full configuration chassis MCC EPSC 2 extended sub cards 2 p...

Page 15: ...SI 220S12 DC power module RPD1101 48S12 Fan module FANS306 2 1 Overview of components 2 1 1 Classification of components The ISCOM5508 is composed of the following four types of components MCC Extended sub card Power module Fan module Table 2 1 lists components of the ISCOM5508 Table 2 1 Components of the ISCOM5508 Component Name Description MCC EPSC Control management aggregation and switching ca...

Page 16: ...dule Fan module FANS306 Fan module 2 1 2 Appearances of components Appearance of MCC Figure 2 1 shows the appearance of the MCC EPSC Figure 2 1 Appearance of the MCC EPSC Appearance of sub card Figure 2 2 shows the appearance of the EP4B sub card Figure 2 2 Appearance of the EP4B sub card Figure 2 3 shows the appearance of the GE4B sub card ...

Page 17: ...d 6 Figure 2 3 Appearance of the GE4B sub card Appearance of power module Figure 2 4 shows the appearance of the power module Figure 2 4 Appearance of the power module Appearance of fan module Figure 2 5 shows the appearance of the fan module Figure 2 5 Appearance of the fan module ...

Page 18: ...e 2 6 Figure 2 6 Hardware information label on the ISCOM5508 The position of hardware information labels may be different because the layouts of elements are different so search for it carefully Table 2 2 lists items on the hardware information label Table 2 2 Items on the hardware information label Item Description P N Name and type of the component REV Hardware version of the component where A m...

Page 19: ...of the EPSC card 2 2 3 Interfaces There are 12 interfaces on the EPSC card Table 2 3 lists interfaces on the EPSC card Table 2 3 Interfaces on the EPSC card Interface Type Usage Description CONSOLE RJ45 Local maintenance serial interface RS 232 serial interface SNMP RJ45 Remote network management interface 10 100BASE T self adaptive electrical interface GE 1 2 RJ45 Ethernet service interface 10 10...

Page 20: ...r RJ45 Interface rate 10 100BASE T auto negotiation Wiring Support straight through and crossover cable self adaption in host mode Compliant standard IEEE 802 3 Table 2 6 lists parameters of the GE interface Table 2 6 Parameters of the GE interface based on 10 100 1000BASE T standard Parameter Description Connector RJ45 Working mode 10 100 1000 Mbit s auto negotiation Full duplex and half duplex a...

Page 21: ...interface is working at 100 Mbit s Off the electrical interface is working at 10 Mbit s LNK ACT 1 2 3 4 SFP optical interface Green Line working LED Green the interface is connected properly Blinking green the interface is transmitting data Off the interface is disconnected or connected improperly LNK ACT 1 2 RJ45 electrical interface integrated LED Green Line working LED Green the interface is co...

Page 22: ...SCOM5508 providing 4 EPON SFP interfaces 2 3 2 Panel and slots The EP4B sub card can be inserted into slot 2 or slot 3 of the ISCOM5508 Figure 2 8 shows the panel of the EP4B sub card Figure 2 8 Panel of the EP4B sub card 2 3 3 Interfaces There are 4 interfaces on the EP4B sub card Table 2 9 lists interfaces on the EP4B sub card Table 2 9 Interfaces on the EP4B sub card Interface Type Usage Descri...

Page 23: ...ED Green the PON interface is connected properly and there is a registered ONU working on the interface or there is a long luminous ONU Off the PON interface is disconnected or there is no registered ONU working on the interface 2 3 5 Technical specifications Table 2 11 lists technical specifications of the EP4B sub card Table 2 11 Technical specifications of the EP4B sub card Item Description Dim...

Page 24: ... electrical module type 1000BASE T Table 2 13 lists parameters of the SFP optical interface Table 2 13 Parameters of the 1000BASE X SFP optical interface Parameter Description Connector LC PC Optical interface properties Depend on the SFP optical module Working mode Full duplex Compliant standard IEEE 802 3 Supported network protocol IP For details of the optical module see chapter 4 Pluggable mod...

Page 25: ...Ethernet interface is transmitting data Off the Ethernet interface is disconnected or connected improperly 2 4 5 Technical specifications Table 2 15 lists technical specifications of the GE4B sub card Table 2 15 Technical specifications of the GE4B sub card Item Description Dimensions 129 4 mm Width 243 4 mm Depth 19 8 mm Height Weight 0 23 kg Power consumption 4 W 2 5 AC power module RPA1101 SI 2...

Page 26: ...ions 2 5 2 Panel and slots The RPA1101 power module can be inserted into slot 4 or slot 5 Figure 2 10 shows the panel of the RPA1101 power module Figure 2 10 Panel of the RPA1101 power module 2 5 3 Interfaces There is 1 interface on the RPA1101 power module Table 2 16 lists the interface on the RPA1101 power module Table 2 16 Interface on the RPA1101 power module Interface Usage 100V 240V AC power...

Page 27: ...ions of the RPA1101 power module Table 2 18 Technical specifications of the RPA1101 power module Item Description Dimensions 65 6 mm Width 240 6 mm Depth 41 2 mm Height Weight 0 61 kg AC power Rated voltage 110 220 VAC Frequency 50 60 Hz Voltage range 100 240 VAC Output power 100 W Lightning protection level AC power Differential mode 1 kV Common mode 2 kV 2 6 DC power module RPD1101 48S12 2 6 1 I...

Page 28: ...ts the interface on the RPD1101 power module Table 2 19 Interface on the RPD1101 power module Interface Usage BGND power input 48 V power input Grounding 2 6 4 LEDs There are 3 LEDs on the RPD1101 power module Table 2 20 lists LEDs on the RPD1101 power module Table 2 20 LEDs on the RPD1101 power module LED Status Description PWR Green Power LED Green the power supply is working properly Off the po...

Page 29: ...5 6 mm Width 240 6 mm Depth 41 2 mm Height Weight 0 49 kg DC power Rated voltage 48 VDC Voltage range 38 to 72 VDC Output power 100 W 2 7 Fan module FANS306 2 7 1 Introduction The FANS306 module is the fan module of the ISCOM5508 It supports the following features Support fan monitoring The system monitors the working status of the fan and an alarm is generated when the fan fails Support adjusting...

Page 30: ...PWR Green Power LED Green the power supply is working properly Off the power supply is working improperly ALM Red Alarm LED Red the module is working improperly and an alarm is generated Off the module is working properly 2 7 4 Technical specifications Table 2 23 lists technical specifications of the FANS306 module Table 2 23 Technical specifications of the FANS306 module Item Description Dimensio...

Page 31: ...s single mode fiber and the orange one is the multi mode fiber The ISCOM5508 can be connected to the Optical Distribution Frame ODF or optical interfaces of other devices through fiber Table 3 1 lists the type and usage of the fiber Table 3 1 Type and usage of the fiber Usage Local connector Remote connector Type Standard Connect the ISCOM5508 to the ODF through the Ethernet optical interface Conn...

Page 32: ...ose a connector suitable for the optical interface Otherwise it may increase additional loss of fiber links reduce transmission quality of services or even damage the connector and optical interface 3 1 2 Connector Fiber connectors are different in shape ferrule end face and pigtail sheath color as shown in Table 3 2 Table 3 2 Fiber connectors Connector Description Pigtail sheath color LC PC Clamp...

Page 33: ...SC PC fiber connector Figure 3 2 SC PC fiber connector When connecting or removing the SC PC fiber connector align the connector with the optical interface and do not rotate the fiber Operate as below To connect the fiber align the head of the fiber r with the optical interface and insert the fiber into the interface gently To remove the fiber push the fiber head inwards and then pull the fiber ou...

Page 34: ... 3 shows the appearance of the Ethernet cable Figure 3 3 Ethernet cable 3 2 3 Technical specifications The Ethernet cable can be divided into two types Straight through cable both two RJ45 connectors of the straight through cable follow EIA TIA568B wiring Crossover cable one RJ45 connector of the crossover cable follows EIA TIA568A wiring the other RJ45 connector follows EIA TIA568B wiring Straigh...

Page 35: ...igure 3 4 shows wiring of the straight through cable Figure 3 4 Wiring of the straight through cable wiring Crossover cable Wiring of the 100 Mbit s crossover cable is different from that of the 1000 Mbit s crossover cable One RJ45 connector of the 100 Mbit s crossover cable follows EIA TIA568A wiring the other RJ45 connector follows EIA TIA568B wiring Figure 3 5 shows wiring of the 100 Mbit s cro...

Page 36: ... cable The 1000 Mbit s crossover cable uses all 8 wires of the twisted pair cable The crossover is PIN 1 to PIN 3 PIN 2 to PIN 6 PIN 4 to PIN 7 and PIN 5 to PIN 8 Figure 3 6 shows wiring of the 1000 Mbit s crossover cable Figure 3 6 Wiring of the 1000 Mbit s crossover cable Table 3 5 lists technical specifications of the Ethernet cable ...

Page 37: ...m 3 3 Configuration cable 3 3 1 Introduction The configuration cable is used to connect the Console interface of the ISCOM5508 and the RS 232 serial interface of the maintenance console and transmit configuration data signals The maintenance console troubleshoots and maintains the ISCOM5508 through the Console interface The configuration cable is an 8 core UTP cable Connectors at the two ends are ...

Page 38: ...n both connectors of the ISCOM5508 PINs on both connectors of the ISCOM5508 Table 3 6 lists PIN definitions of the Console interface and RJ45 interface Table 3 6 PIN definitions of the Console interface and RJ45 interface PIN No PIN function Device RJ45 Maintenance console DB9 PIN 1 NC DCD PIN 2 NC RxD PIN 3 RxD TxD PIN 4 GND DTR PIN 5 GND GND PIN 6 TxD DSR PIN 7 NC RTS PIN 8 NC CTS PIN 9 RI Wirin...

Page 39: ...tion cable Item Description Name CBL RS232 DB9F RJ45 2m Connector type DB9 female connector and RJ45 connector Cable type Cat 5 unshielded flat cable Number of cores 8 Length 2 m 3 4 DC power cable 3 4 1 Introduction The DC power cable supplies 48 VDC power from the power souring equipment to the power interface on the RPD1101 module of the ISCOM5508 and then transmits power to the entire device 3...

Page 40: ...h which is customized For example if the customer requires 2 meter cables they are named POL DC unstripped stripped 2m 3 5 AC power cable 3 5 1 Introduction The AC power cable supplies 110 220 VAC power from the power souring equipment to the power interface on the RPA1101 module of the ISCOM5508 and then transmits power to the entire device Types of the AC power cable of the ISCOM5508 depend on d...

Page 41: ...ecifications of the European standard AC power cable Item Description Name European standard French mode head receptacle 10A 250V D RoHS Connector European standard French mode 3 pin plug and IEC60320 C13 receptacle Model Copper core multi strand power cable 18 AWG 0 75 mm2 Length The letter D indicates the length which is customized For example if the customer requires 2 meter cables they are nam...

Page 42: ...ust be connected to the grounding cable correctly during installation which helps avoid personal injury and equipment damage 3 6 1 Introduction The grounding cable is used to ground the ISCOM5508 3 6 2 Appearance The grounding cable is composed of two grounding terminals and the coaxial cable In general grounding terminals are OT bare pressure terminals and the coaxial cable is a yellow green copp...

Page 43: ...t RoHS requirements Conducting wire Yellow Green multi strand copper core conducting wire 16 AWG 1 25 mm2 Electronic wire UL1007 or UL1005 is used Stripped end 10 mm long and plated with tin Insulating sheath 3 5 1 75 black heat shrink tubing which is a 20 mm plastic tube and shrinks when heated Welding technology The conducting wire and OT terminals adopt solderless pressed connection Error in le...

Page 44: ...ons 4 3 soldering lug Inner radius of soldering lug 4 mm Outer radius of soldering lug 8 mm Inner radius of sheath 2 1 mm Thickness of soldering lug 0 6 mm Cross sectional area of conducting wire 16 15 AWG 1 2 1 5 mm2 The ISCOM5508 is delivered without the grounding cable If required prepare or make grounding cables on site The grounding cable cannot be longer than 30 m and should be as short as p...

Page 45: ...1 1000 Mbit s SFP optical module 4 1 1 Functions and appearance The 1000 Mbit s Small Form factor Pluggables SFP optical module is applicable to the 1000 Mbit s telecommunication network It is integrated with sending and receiving features Figure 4 1 shows the appearance of the 1000 Mbit s SFP optical module Figure 4 1 1000 Mbit s SFP optical module 4 1 2 Label There is a label on the bottom of th...

Page 46: ...nt values of which indicate the same function R Comply with RoHS 1310nm Tx wavelength 1310 nm SM Single mode fiber DDM Support link detection 21CFR J Comply with U S DHHS 21CFR J Class1 Comply with class 1 laser safety 4 1 3 Technical specifications Table 4 2 lists technical specifications of the 1000BASE X SFP optical module Table 4 2 Technical specifications of the 1000BASE X SFP optical module ...

Page 47: ...4 2 1 Functions and appearance The 1000 Mbit s SFP electrical module is applicable to the 1000 Mbit s telecommunication network It is integrated with sending and receiving features Figure 4 3 shows the appearance of the 1000 Mbit s SFP electrical module Figure 4 3 1000 Mbit s SFP electrical module 4 2 2 Techinical specifications Table 4 3 lists technical specifications of the 1000BASE T SFP electr...

Page 48: ...ace on the ISCOM5508 supports the optical module compliant with the 1000BASE PX20 D standard There is a label on the bottom of the SFP optical module which describes the model of the SFP optical module as shown in Figure 4 5 Figure 4 5 Label of the PON SFP optical module Table 4 4 describes the model of the PON SFP optical module Table 4 4 Model of the PON SFP optical module Field Description GSFP...

Page 49: ...ns Table 4 5 lists technical specifications of the CLASS B optical module Table 4 5 Technical specifications of the CLASS B optical module Item Description Model GSFP PX20DM R Transmission rate Tx 1 25 Gbit s Rx 1 25 Gbit s Interface type SC PC Max transmission distance 20 km Fiber mode Single mode fiber Central wavelength Laser type Tx 1490 nm DFB Rx 1310 nm APD TIA Tx optical power 2 7 dBm Extin...

Page 50: ... transmitting data Off the interface is disconnected or connected improperly LNK ACT 1 2 RJ45 electrical interface integrated LED Green Line working LED Green the interface is connected properly Blinking green the interface is transmitting data Off the interface is disconnected or connected improperly 1000M RJ45 electrical interface integrated LED Yellow Electrical interface working rate LED Yello...

Page 51: ...LED Red the device is working improperly and an alarm is generated Off the device is working properly AC Green AC power working LED Green the power module is working properly Off the power module is working improperly DC Green DC power working LED Green the power module is working properly Off the power module is working improperly ...

Page 52: ...ower consumption of the ISCOM5508 Component Parameter Standard configuration Weight 5 51 kg Power consumption 40 W Full configuration Weight 6 24 kg Power consumption 63 W EPSC Weight 0 89 kg Power consumption 32 W EP4B Weight 0 37 kg Power consumption 10 W GE4B Weight 0 23 kg Power consumption 4 W RPA1101 Weight 0 61 kg Output power consumption 100 W RPD1101 Weight 0 49 kg Output power consumptio...

Page 53: ...n 6 Lookup table of weight and power consumption Raisecom Technology Co Ltd 42 Standard configuration chassis MCC EPSC 2 power modules and 1 fan module Full configuration chassis MCC EPSC 2 extended sub cards 2 power modules and 1 fan module ...

Page 54: ... It takes 44 45 mm as basic unit namely 1 U 44 45 mm A Auto negotiation The Ethernet interface chooses the rate and duplex mode according to the result of negotiation B Bracket Small parts at the side of chassis being used to install the chassis into the cabinet E ETSI 600 cabinet Cabinet with width of 600 mm depth of 600 mm compliant with the ETSI standard F Full duplex In a communication link bo...

Page 55: ...usual Level 1 indicates the safest laser power of which is usually limited at 1mW It will neither cause fire nor generate harmful radiation under normal conditions M Multi mode fiber In this fiber multi mode optical signals are transmitted P PWE3 Pseudo Wire Emulation Edge to Edge R RS232 In synchronization transfer mode no handshaking signals able to communicate with RS232 or RS422 devices point ...

Page 56: ...tro Static Discharge ETSI European Telecommunications Standards Institute L LLDP Link Layer Discovery Protocol M MPLS Multi protocol label switching O ODF Optical Distribution Frame OAM Operation Administration and Maintenance P PTN Packet Transport Network PTP Precision Time Protocol Q QoS Quality of Service R RH Relative Humidity S SLA Service Level Agreement ...