Raisecom
ISCOM2600G (A) Series Product Description
6 Appendix
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
72
Table 6-6
Technical specifications of DC power cable
Parameter
Description
Name
POL-DC (2 cores)-stripped wire/U-type terminal-
0.75 mm
2
-1.5 m/RoHS
Connector
U-type terminal (flame-retardant tube)
Cable
2-core PVC-sheathed cord
2 × 0.75mm
2
60227 IEC 53 (RVV)
The stripped wire is equipped with a flame-
retardant tube.
+Vin positive wire: brown
-Vin negative wire: blue
Rated voltage (V)
300/500
Insulation and withstanding voltage
(sheathe of cable core pairs)
2000 VAC, 5min
Insulation and withstanding voltage
(cable core)
1500 VAC, 5min
Certification
CCC
RoHS
Compliant
6.1.5 AC power cable
Introduction
The AC power cable transmits 220 VAC power to the power interface on the ISCOM2600G
series switch, and supplies power for the whole device.
The AC power cables used by the ISCOM2600G series switch vary with countries or regions,
as lists in Table 6-7.
Table 6-7
AC power cables
Regional standard
Cable
Europe
POL-AC-European-3-pin/C13 connector-0.75mm
2
-1.5m/RoHS
America
POL-AC-American-3-pin/C13 connector-18AWG-1.5m/RoHS
Appearance
The AC power cable which meets European standard is composed of the European French
mode 3-pin plug and C13 connector, as shown in Figure 6-9.