background image

         

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

www.raisecom.com 

 
 
 

ISCOM2016 Hardware Installation 
User Manual 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for ISCOM2016

Page 1: ...www raisecom com ISCOM2016 Hardware Installation User Manual ...

Page 2: ...age without the prior written consent of Raisecom Technology Co Ltd The information contained in this document is subject to change without notice Copyright Notices Copyright 2007 Raisecom All rights reserved No part of this publication may be excerpted reproduced translated or utilized in any form or by any means electronic or mechanical including photocopying and microfilm without permission in ...

Page 3: ...86 10 82883056 World Wide Web You can access the most current Raisecom product information on the World Wide Web at the following URL http www raisecom com Feedback Comments and questions about how the ISCOM2016 device works are welcomed Please review the FAQ in the related manual and if your question is not covered send email by using the following web page http www raisecom com en xcontactus con...

Page 4: ...evice Appearance 5 3 1 Device front panel description 5 3 2 Device rear panel description 6 Chapter 4 Installation and Application 7 4 1 Device model 7 4 2 Device installation 7 4 2 1 Environment requirement 7 4 2 2 Install the device on to a rack 7 4 2 3 Grounding 7 4 3 The connection of the switch 7 4 3 1 Connect to console 7 4 3 2 Connect to Ethernet 9 4 3 3 Connect to the power supply 9 4 4 Ca...

Page 5: ...al introduces other reference documents and explains relevant term definitions Chapter 2 Specifications and Dimension This chapter is an instruction of the device specifications device dimension and device operating environment Chapter 3 Device Appearance This chapter describes the panel of the device and the definition of the indicators on the device panel Chapter 4 Installation and Application T...

Page 6: ...at the fiber optic cable is intact and is connected to the transmitter Do not attempt to adjust the laser drive current Do not use broken or unterminated fiber optic cables connectors or look straight at the laser beam The use of optical devices with the equipment will increase eye hazard Use of controls adjustments or performing procedures other than those specified herein may result in hazardous...

Page 7: ...nstalled in a restricted access area i e an area where access is authorized only to qualified service and maintenance personnel Make sure that the DC supply is electrically isolated from any AC source and that the installation complies with the local codes Before connecting the DC supply wires ensure that power is removed from the DC circuit Locate the circuit breaker of the panel board that servi...

Page 8: ...t Ethernet over CAT 5 twisted pair based on 4B 5B coding and running at 100Mbps Auto Negotiation The auto negotiation procedure is the port at one site adapts its bit rate and duplex mode to the highest level it and the opposite site device both support according to the bit rate and duplex mode adopted by the remote site device that is the connected devices on both site adopt the fastest transmiss...

Page 9: ...as 16 10 100BASE TX Ethernet interfaces The power consumption of the device is less than 15W 2 2 Device dimension The dimension of ISCOM2016 switch s main structure is 43 6mm Height x 422mm Width x 120mm Depth The device weighs 2 5kg and can be either installed in a 19 inch cabinet or placed on a table 2 3 Device operating environment Environment temperature 10 C 45 C Storage temperature 40 C 60 C...

Page 10: ...r Color Status Description Flickering The system is operating in order SYS Green Other Status Software fault or the system is initializing after electrifying ON The system is electrified PWR Green OFF The system is not electrified 16 10 100M Ethernet interfaces The 16 groups of indicators for the 16 10 100M Ethernet interfaces There are 2 indicators for an interface LNK ACT SPD and FDX Indicator B...

Page 11: ...corresponding port is working in full duplex mode FDX 10 100M Green OFF The corresponding port is working in half duplex mode or it is in Power OFF status The CONSOLE interface 3 2 Device rear panel description ISCOM2016 only provides a socket for 220V AC power supply on its rear panel see the figure below 1 2 In the figure shown above The place where the socket for 220V AC power supply locates Th...

Page 12: ...evice and fasten the installation handle on to the rack 4 2 3 Grounding To ensure the safety of the device and the operator please make sure that the grounding terminal is well connected to the earth 4 3 The connection of the switch 4 3 1 Connect to console ISCOM2016 switch provides a RS 232 interface in the form of RJ 45 as the CONSOLE interface After connecting the CONSOLE interface of ISCOM2016...

Page 13: ...nector is shown in the figure and table below Pin Number Function Type Pin Number Function Type 1 CD 6 DSR 2 RxD IN 7 RTS 3 TxD OUT 8 CTS 4 DTR 9 RI 5 GND 3 CONSOLE interface connecting pattern and parameter setup The connecting of ISCOM2016 CONSOLE interface and PC serial port is shown in the figure below RxD TxD GND RxD TxD GND PC Serial Pot ISCOM2016 CONSOLE 3 2 5 6 3 4 5 The values of the conn...

Page 14: ...n in the table below For the pin numbering of RJ 45 connector and jack please refer to the CONSOLE interface signal definitions of the switch in section 4 3 1 Pin Number MDIX Signal MDI Signal 1 RD TD 2 RD TD 3 TD RD 6 TD RD 4 5 7 8 N C N C The 16 10 100M Ethernet electrical interfaces of ISCOM2016 switch works at MDIX mode when the auto negotiation function is disabled In this circumstance the in...

Page 15: ...tch is electrified After the electrifying the indicator PWR will turn ON to indicate that the power supply of the system is working The switch will begin its self check and initialization in succession All the indicators on the front panel of the switch will turn ON during this procedure The switch will be in operating status after the self check and initialization The indicator SYS will begin to ...

Page 16: ...w humidify may lead to fire alarm In a word the switch must be placed in proper surroundings The power supply of the device should be well earthed to let out the static electricity Please keep some space from other powered devices when installing the switch The cable arrangement of the switch should have all cables be placed across the live wire Long distance close parallel of the cables and the l...

Page 17: ...ress 2nd Floor South Building of Rainbow Plaza No 11 Shangdi Information Road Haidian District Beijing Postcode 100085 Tel 86 10 82883305 Fax 86 10 82883056 Email export raisecom com http www raisecom com ...