Raisecom
Gazelle S1503i (A) User Manual
3
Technical specifications
Raisecom Technology Co., Ltd.
29
Item
Parameter
Frequency
50/60 Hz
–
Overload protection
Supported
Reverse connection protection
Supported
3.2 EMC standards
The Gazelle S1503i is compliant with the following Electromagnetic Compatibility (EMC)
standards:
Electro Magnetic Interference (EMI) meets CISPR 22 CLASS A related requirements.
Static electricity meets IEC 61000-4-2 level 3 requirements.
Radiated Immunity Test (RIT) meets IEC 61000-4-3 level 3 requirements.
Electrical Fast Transient (EFT) meets IEC 61000-4-4 level 3 requirements.
Damped oscillation meets IEC 61000-4-12 level 3 requirements.
Surge (impact) meets IEC 61000-4-5 level 4 requirements.
Power Frequency Magnetic Field meets IEC 61000-4-8 level 3 requirements.
Pulse Magnetic Field meets IEC 61000-4-9 level 3 requirements.
Damped Oscillation Magnetic Field meets IEC 61000-4-10 level 3 requirements.
Conducted Immunity (CI) meets IEC 61000-4-6 level 3 requirements.
DC power sag or temporary interruption immunity meets IEC 61000-4-29 requirements.
AC power voltage falling and interruption meet IEC 61000-4-11 requirements.
3.3 Environmental standards
The Gazelle S1503i is applicable to the industrial environment and environmental
requirements are as shown in Table 3-2.
Table 3-2
Environmental requirements of the Gazelle S1503i
Item
Range
Air pressure
86–106 kPa
Operating temperature
-40 to 75°C
Storage temperature
-40 to 85°C
Operating humidity
5%–95% RH (non-condensing)
Protection level
IP40
Environmental authentication
Comply with EU RoHS standard.