4 Hardware installation
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
41
4.4.3 Connecting power cable
Connecting DC power cable
Confirm the power type supported by the Gazelle S1020i-LI before installing the
power cable. Connect the proper power voltage to the corresponding PINs
according to the marks displayed on the device shell. Otherwise, the Gazelle
S1020i-LI will be damaged or fail to be started normally.
Ensure that the ground cable is correctly grounded before connecting the power
cable.
Disconnect all power supplies before connecting or removing the power cable.
Use the power cable which meets the technical specifications.
The DC power interface of the Gazelle S1020i-LI is a 2-PIN Phoenix terminal. Connect the
DC power cable as below:
Step 1
Make the DC power cable according to specifications.
Step 2
Insert the DC power connector into the DC power interface of the Gazelle S1020i-LI snuggly
and tighten the screws at both sides of the connector, as shown in Figure 4-8.
Figure 4-8
Connecting the DC power connector
Step 3
Connect the other end of the DC power cable to the cabinet or the power sourcing equipment
in the machine room.
4.5 Powering on device
Power on the Gazelle S1020i-LI as below:
The Gazelle S1020i-LI can be powered on after being inserted with the power cable and
installed properly.
The Gazelle S1020i-LI is powered on when the power LED (PWR) is lightening up.
The Gazelle S1020i-LI begins to operate properly after Power-on Self-Test (POST) and
initialization. Interface LEDs indicate the working status of the interface (lit up, off, or
blinking)