Raisecom
Gazelle S1020i-LI (A) User Manual
3 Technical specifications
Raisecom Proprietary and Confidential
Copyright © Raisecom Technology Co., Ltd.
33
Table 3-1
Reliability indicators
Parameter
Requirements
System availability
99.999%. The annual failure time for the Gazelle
S1020i-LI should be no longer than 5 minutes.
Annually system mean repair rate
< 1.5%
MTTR
< 2 hours
3.1.4 Safety standards
The Gazelle S1020i-LI meets UL60950 requirements.
3.1.5 EMC standards
The Gazelle S1020i-LI is compliant with the following Electromagnetic Compatibility (EMC)
standards:
Electro Magnetic Interference (EMI) meets CISPR 32 CLASS A requirements.
Static electricity meets IEC 61000-4-2 level 4 requirements.
Radiated Immunity Test (RIT) meets IEC 61000-4-3 level 3 requirements.
Electrical Fast Transient (EFT) meets IEC 61000-4-4 level 4 requirements.
Damped oscillatory wave meets IEC 61000-4-18 level 3 requirements.
Surge (impact) meets IEC 61000-4-5 level 4 requirements.
Power frequency magnetic field meets IEC 61000-4-8 level 4 requirements.
The pulse magnetic field meets IEC 61000-4-9 level 5 requirements.
Damped oscillatory magnetic field meets IEC 61000-4-10 level 4 requirements.
Conducted Immunity (CI) meets IEC 61000-4-6 level 3 requirements.
AC voltage dips and short interruptions immunity meets IEC 61000-4-11 requirements.
DC voltage dips and short interruptions immunity meets IEC 61000-4-29 requirements.
3.1.6 Environmental standards
The Gazelle S1020i-LI is applicable to the industrial environment with environmental
requirements shown in Table 3-2.
Table 3-2
Environmental requirements
Parameter
Description
Air pressure
86–106 kPa
Operating temperature (altitude: 0–1800 m)
-40 to 75°C
Storage temperature
-40 to +85°C
Operating humidity
5%–95% RH (non-condensing)
Protection class
IP40