background image

How to Replace the Heating Rods – V 1.0                                                                                                                    Date

21/10/2019 

- 8 / 10 - 

www.raise3d.com 

17.

 

Reconnect the heating rod cable to the terminal slot marked HE_0 or HE_1. Reconnect the 
temperature sensor cable into the terminal slot marked TS0 or TS1. 

 

 

18.

 

Reinstall the two retaining screws with a 2 mm hex wrench.

 

Summary of Contents for E2

Page 1: ...the Heating Rods V 1 0 Date 21 10 2019 1 10 www raise3d com Manual E2 How to Replace the Heating Rods V1 0 Required tool 2 mm hex wrench 1 Power off the machine 2 Release the extruder connection cable retaining buckle ...

Page 2: ...21 10 2019 2 10 www raise3d com 3 Use a 2 mm hex wrench to remove the two screws retaining the extruder connection board cover to the extruder 4 Use a 2 mm hex wrench remove the two screws retaining the extruder connection board to the extruder ...

Page 3: ...019 3 10 www raise3d com 5 Gently pull out the extruder connection board in the direction of the arrow shown below Be mindful of the small protrusion holding it in place 6 Remove the two cables from the slots marked in red as shown in the picture below ...

Page 4: ...Rods V 1 0 Date 21 10 2019 4 10 www raise3d com 7 Use a 2 mm hex wrench to remove the hotend retaining screw At this step the entire hotend assembly can be removed along with the heating rod and thermocoupler 8 Remove the hotend ...

Page 5: ...h a 2 mm hex wrench 10 Once the retaining screw is loosened the heating rod should be able to slide out Note If the heating rod is not able to slide out freely you can use a small flat head screwdriver to gently flex the heating block At that point there should be enough clearance for the heating rod to slide out smoothly ...

Page 6: ...ng rod into the heating block Note Ensure that the tip of the heating element is flush with the block as shown in the picture below 13 Reinstall the screw retaining the heating rod Note Reinstall the screw firmly but not so tightly that the heating rod is compressed 14 Insert the hotend back into the extruder facing the back of the printer ...

Page 7: ...com 15 Once the hotend is inserted fully into the extruder use a 2 mm hex wrench to tighten the screw to retaining the hotend 16 Plug the small protrusion of the board into the hole on the extruder Once it s installed properly tuck the cables into the cable management slot ...

Page 8: ... 10 2019 8 10 www raise3d com 17 Reconnect the heating rod cable to the terminal slot marked HE_0 or HE_1 Reconnect the temperature sensor cable into the terminal slot marked TS0 or TS1 18 Reinstall the two retaining screws with a 2 mm hex wrench ...

Page 9: ...ection board cover with the buckle facing the extruder connection cable socket After reinstallation the machine will need to undergo calibration On RaiseTouch select Setting Machine Maintenance Offset Calibration and follow the steps on the screen Manual E2 How to Replace the Heating Rods V1 0 END ...

Page 10: ... to Replace the Heating Rods V 1 0 Date 21 10 2019 10 10 www raise3d com America Asia Europe Sales Business sales raise3d com Technical Support help raise3d com For any other inquiries inquiry raise3d com ...

Reviews: