background image

1

ENGLISH             RAIS - manual for SIRA & SIRA SOAPSTONE                                    

U S E R   M A N U A L

RAIS SIRA & RAIS SIRA SOAPSTONE

Summary of Contents for SIRA

Page 1: ...1 ENGLISH RAIS manual for SIRA SIRA SOAPSTONE U S E R M A N UA L RAIS SIRA RAIS SIRA SOAPSTONE...

Page 2: ...ION DISTANCE IN CASE OF COMBUSTIBLE WALL 14 15 GENERAL INSTALLATION RIGHT ANGLE SECURE BASE 15 CORNER INSTALLATION 45 15 INSTALLATION DISTANCE IN CASE OF NON COMBUSTIBLE WALL 15 FOR THE INSTALLER 16 O...

Page 3: ...stove In the UK the stove has been approved by HETAS Ltd as an intermittent operating appliance for burning wood logs only A RAIS wood burning stove is more than just a heat source it also shows that...

Page 4: ...listing of their Registered Competent Persons can be found on their website at www hetas co uk It should be noted that the current Building Regulations requirements are given in Approved Document J Th...

Page 5: ...ocument J or a twin walled insulated stainless steel flue to BS 4543 can be used These chimneys must be fitted in accordance with the manufacturer s instructions and Building Regulations A single wall...

Page 6: ...rop erly Tighten the assembly using the 3 M6 nuts Remove the baffle plate and the smoke chicane see cleaning and care Installation It is prohibited to carry out unauthorised alterations to the stove T...

Page 7: ...rter are assembled with 3 M6x20 head cap screws and M6 nuts The smoke leader and baffelplate are assembled in re verse order Assemble the reflector plate and backpanel Installation of soapstone List o...

Page 8: ...rdance with UK Building Regulations Approved Docu ment J to a distance of 300 mm in front of the stove and 150 mm to each side measuring from the door of the combustion chamber The clearance distances...

Page 9: ...the appliance and appliance connections to the chimney Ensure that the appliance and chimney flue are functioning correctly before finally handing over to the user If necessary read the later parts of...

Page 10: ...those recommend ed the stove is subjected to a larger amount of heat which results in a higher chimney temperature and lower efficiency This can result in the stove and chimney becoming dam aged and w...

Page 11: ...ed optimally as there is oxygen for combustion and for the burning of the pyrolysis gases When the flames are a clear yellow the damper has been set correctly Finding the correct position comes with t...

Page 12: ...g heating and cooling caused by the large temperature differences which the material is subjected to Never use any type of liquid fuel for kindling or maintaining the fire You could be at risk of expl...

Page 13: ...use alcohol briquettes or similar as well as approx 2 kg of firewood split into kindling sticks Set the air damper to the fully open position Light the fire and shut the door leaving the door ajar app...

Page 14: ...g agent cannot handle it is possible to abrade the stone slightly Cleaning the combustion chamber Scrape shovel the ash out and store it in a non flammable container until it has cooled down You can d...

Page 15: ...by leak around the door seal chimney draught too large 22 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for...

Page 16: ...061090 95 Door 6 1 306010790 95 Back panel 7 1 306170890 95 Back panel f air box 8 set 3064001 3064002 Ashpan with cover 9 1 5031790 95 Airbox 10 1 3064105 Heat shield 11 1 3065500 Seal set 12 1 30622...

Page 17: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn www rais dk...

Reviews: