Finally before firing the stove for the first time a check should be made to ensure that the
assembly and stove installation has been satisfactory and that there are no leaks in any
seals in the appliance and appliance connections to the chimney.
Ensure that the appliance and chimney flue are functioning correctly before finally
handing over to the user. Read the later parts of this manual for guidance on care
required when first lighting.
Inform the user that the appliance has been commissioned and ready to use and give
instruction on the safe operation of the stove.
These Instructions must be left with the user and the user should be instructed to keep
them in a safe place.
Installation distances for non combustible wall
We recommend a minimum distance to non combustible material of 50mm ( F ) for cleaning
considerations.
Using uninsulated flue pipe, the minimum distance to a combustible wall must be 450mm or
225mm if the wall is heatshielded ( see Section J of the Building Regulations ) from the flue
pipe.