52
English
RAIS - Manual for RAIS Q-Tee
Installation distance in case of brick wall / fire wall
A-A
A
A
Min. convection area 600 cm
2
above
the stove (may be distributed)
Distance to
furniture
min. 650 mm
Distance to non-
combustible 0 mm
(10 mm is recommended)
Installation
height
min. 400 mm
Min. convection area 350 cm
2
be-
low the stove (may be distributed)
To guide the hot air out of the convection outlets RAIS recom-
mends to mount a non-combustible plate above the outlets.
Min. 50 mm
Min. 300 mm
Distance to non-combustible
plate min. 800 mm
Distance to combustible
material min. 300 mm