background image

ENGLISH

 

RAIS ­ manual for Rais Poleo and Rais Epoca 

1

 

INSTRUCTIONS FOR INSTALLATION, 

USE AND MAINTENANCE 

RAIS POLEO & RAIS EPOCA 

IMPORTANT INFORMATION 

On first lighting the stove you must be careful not to touch the painted 

surfaces and it is MOST IMPORTANT that the door is kept slightly ‘ajar’ in 

order for the door seal and sealant to cure. 

This will prevent the door seal sticking to the painted body and becoming 

damaged.

Summary of Contents for POLEO

Page 1: ...LEO RAIS EPOCA IMPORTANT INFORMATION On first lighting the stove you must be careful not to touch the painted surfaces and it is MOST IMPORTANT that the door is kept slightly ajar in order for the doo...

Page 2: ...ENGLISH RAIS manual for Rais Poleo and Rais Epoca 2...

Page 3: ...T ANGLE SECURE BASE 15 CORNER INSTALLATION 45 16 360 SWIVEL BASE 17 INSTALLATION DISTANCE TO NON COMBUSTIBLE WALL 18 FOR THE INSTALLER 19 OPERATING INSTRUCTIONS 20 FUEL 20 DRYING AND STORAGE 21 ADJUST...

Page 4: ...er We therefore recommend that you note down the number in the table below The production number is located at the back of the stove at the bottom WARRANTY Your Rais wood burning stove comes with a 5...

Page 5: ...0 240 380 Recommended amount of wood when fuelling kg Based on 2 3 logs of wood approx 25cm 1 6 1 6 Min uptake Min draught Pascal 12 12 Weight kg 131 137 Smoke gas mass flow g s 6 4 6 4 Smoke gas temp...

Page 6: ...ce The installation of this heating appliance is governed by the Health and Safety at Work Act 1974 it is the responsibility of the installer to ensure that all requirements of this Act are met during...

Page 7: ...vide sufficient draught The outlet from the chimney should be above the roof of the building in accordance with the provisions of Building Regulations Approved Document J If installation is into an ex...

Page 8: ...off the stove immediately and isolate the mains electricity supply if applicable and tightly close the doors of the stove This should cause the chimney fire to go out If the chimney fire does not go...

Page 9: ...utlets which may be connected with suit able air ducts to other rooms Building Regulations Approved Document J gives specific guidance on the required permanent ventilation into the room for combustio...

Page 10: ...base If the stove has a revolving base then please do the following Push pull the pedal release arm after which the stove can be turned at 30 intervals When the stove is in the desired position let g...

Page 11: ...nnection as follows Remove the baffle plate and smoke diverter see cleaning and care Loosen the three M6 nuts with a spanner Epoca Lift one of the two part reflector plates up and break off the knock...

Page 12: ...in the top make sure that the seal is positioned properly Tighten the assembly using the three M6 nuts The flue outlet spigot which can be found in the stove in a bag and the holder for the upper flu...

Page 13: ...ENGLISH RAIS manual for Rais Poleo and Rais Epoca 13...

Page 14: ...ns Commissioning and handover Ensure all parts are fitted in accordance with the instructions On completion of the installation allow a suitable period of time for any fire cement and mortar to dry ou...

Page 15: ...ENGLISH RAIS manual for Rais Poleo and Rais Epoca 15...

Page 16: ...ENGLISH RAIS manual for Rais Poleo and Rais Epoca 16...

Page 17: ...l for Rais Poleo and Rais Epoca 17 Using uninsulated flue pipe the minimum distance to a combustible wall must be 450mm or 225mm if the wall is heatshielded see Section J of the Building Regulations f...

Page 18: ...ais Poleo and Rais Epoca 18 Installation distance to non combustible wall We recommend a minimum distance to non combustible material of 50mm F for cleaning considerations It should always be possible...

Page 19: ...and appliance connections to the chimney Ensure that the appliance and chimney flue are functioning correctly before finally handing over to the user Read the later parts of this manual for guidance...

Page 20: ...d laminated or impregnated wood wood with a synthetic surface painted refuse wood chipboard plywood domestic waste paper bri quettes and pit coal as this will produce malodorous smoke which could be p...

Page 21: ...n chamber and is pre heated through the side channels and then emitted as hot scaveng ing air onto the glass The hot air rinses the glass and keeps it soot free The tertiary channel which can be seen...

Page 22: ...tween position 1 and 2 When the flames are clear and yellow the damper is set correctly i e resulting in a slow optimal burning Position 3 Push the lever upwards and to the right The air damper is com...

Page 23: ...osion The stove gets very hot when in use always wear protective gloves when tending the stove If the stove has not been used for a while follow the steps as if you were using it for the first time IM...

Page 24: ...indow close to the wood burning stove If there is storm in the stove coming from the chimney it is advisable to place a screwed up piece of newspaper between the upper baffle plate and the chimney Lig...

Page 25: ...ve a good bed of glowing embers add 2 3 pieces of wood Leave the door ajar until the fire has caught properly then close the door Damper see adjustment of the damper After approximately 5 minutes or w...

Page 26: ...be left unused for a prolonged period of time then it should be given a thorough clean to remove ash and unburned fuel residues To enable a good flow of air through the appliance to reduce condensatio...

Page 27: ...Carefully pull out the plate Next remove the flue diverter by lifting it up and pulling it forward Carefully lift out the flue diverter Remove any dust and dirt and assemble in reverse order The flue...

Page 28: ...himney draught too large 22 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for the room ventilation dirty smok...

Page 29: ...ESSORIES AND SPARE PARTS If spare parts other than those recommended by RAIS are used the warranty is voided All replacement spare parts can be purchased from your RAIS distributor stockist See the fo...

Page 30: ...ENGLISH RAIS manual for Rais Poleo and Rais Epoca 30...

Page 31: ...ENGLISH RAIS manual for Rais Poleo and Rais Epoca 31...

Page 32: ...ENGLISH RAIS manual for Rais Poleo and Rais Epoca 32...

Page 33: ...ENGLISH RAIS manual for Rais Poleo and Rais Epoca 33...

Page 34: ...ENGLISH RAIS manual for Rais Poleo and Rais Epoca 34...

Reviews: