Air-dried wood has less moisture (15 – 20 %) than freshly-cut timer (40%),and typically 

yields 20 % more available heat. Wet wood burns at a lower temperature and causes 

incomplete combustion (soot and “creosote” formation, which in extreme cases, can lead 

to a chimney fire). The logs should have a length of the width of the firebox less 5-6 cm. 

 

Furthermore condense might arise in the tube or the stove if you burn moist wood. 

 

Burn only the fuel your stove was designed for. Also, trash should not be burned in you 

stove. Besides increasing the chance of starting  a chimney fire, so plastics and other 

trash emit harmful gases, which is unhealthy for you and the environment. Driftwood, 

treated wood, and artificial logs should not be burned either. 

 

Burning value of wood 

 

All types of wood heat up equally per kilogram; however, the density of wood is not the 

same, as shown in the following table: 

 

 

Type of wood 

Kg dry wood per m³ 

Compared to beech 

 

 

 

Beech and oak 

580 

100 % 

Ash 

570 

98 % 

Maple 

540 

93 % 

Birch 

510 

88 % 

Mountain pine 

480 

83 % 

Fir 

390 

67 % 

Poplar 

380 

65 % 

 

 

A few reminders 

 

Store your wood cut and split (split logs dry faster). 

 

Keep the wood pile in a dry sunny place, protected from the rain. Don’t cover the pile with 

plastic, because that will prevent the wood from drying out properly. 

 

Stack the wood with enough space between the rows to ensure a good air circulation ! 

Summary of Contents for Malta

Page 1: ...RAIS Malta RAIS Bando MANUAL Rev B 290802 RAIS A S Industrivej 20 9900 Frederikshavn Denmark Phone 98 47 90 33 Fax 98 47 92 91 E mail info rais dk Website www rais dk...

Page 2: ...the fire Page 7 FIREWOOD Firewood Page 7 Burning value of wood Page 8 A few reminders Page 8 Verification Page 9 Surface temperature Page 9 CARE AND MAINTENANCE Care and maintenance Page 9 Cleaning of...

Page 3: ...ical fans kitchen fans and bathroom etc which may affect the proper draw We suggest that you have a professional mason or stove installer do a complete check up of your existing chimney liner and flue...

Page 4: ...back wall E Distance to inflammable material wall A B C D E RAIS Malta RAIS Bando 900 300 150 150 400 When using smoke outlet at the top and non insulated tube the distance to flammable wall must be 4...

Page 5: ...ings on the stove Mount the holding fittings on the soapstone panels Remember to put the screws into the right holes NB Do not over tighten the screws Mount the soapstone panels on the stove and push...

Page 6: ...ratures and then gradually increase the intensity For the first few fires you may detect a strange smell that comes from heat Treating the paint and materials This is normal and will soon disappear Ju...

Page 7: ...htly cracked with supervision about 1 2 inches 10 15 mm until you have clear flames After 3 5 minutes close the door completely After approx 10 20 minutes of burning you may add 1 2 pieces of split lo...

Page 8: ...tics and other trash emit harmful gases which is unhealthy for you and the environment Driftwood treated wood and artificial logs should not be burned either Burning value of wood All types of wood he...

Page 9: ...fore get rather hot The stove is equipped with a cool handle a speciality from RAIS which enables you to touch the handle without the use of a glove Care and maintenance Your RAIS requires very little...

Page 10: ...ull it out carefully Push up the smoke leader 1 lift it from the rivets 3 and take it out Please notice The baffle plate is made out of vermiculite slab insulation skamol This is a porous material and...

Page 11: ...gh draft in the chimney 16 Pa Soot on the glass take care that the stove is warmed up sufficiently before closing the door If the stove is burning too quickly check the door gaskets first Remember to...

Page 12: ...guarantee on your RAIS stove This guarantee covers any defect in material or workmanship It does not cover damage from misuse or neglect The glass gaskets firebrick and vermiculite are not covered E N...

Reviews: