In order for the stove to work and draw properly, sufficient air is important! Be especially
aware of any mechanical fans (e.g. kitchen or bathroom) that may affect the proper draw.
In addition, make sure that the floor and sub-flooring is designed to carry the extra weight
of the stove. The floor protector or plate must be made of a non-combustible material.
The floor plate must cover under the stove and extend 16” (40.6cm) (18” (45.7cm) in
Canada) in front of the stove door, 8” (20.3cm) beyond the sides of the fuel-loading door,
and under the pipe and 2” (5cm) beyond for back venting.
When installing the stove, the heat distribution to other rooms should be taken into
consideration. The RAIS Malta Series stoves have a heating capacity of approximately
1,076 ft² (100m²) based on a standard ceiling height.