RAIS 700 User Manual Download Page 2

ENGLISH MANUAL

 ...............................................................2-29

FRANÇAIS MANUEL D’UTILISATEUR

  ................................30-51

FLEMISH GEBRUIKERSHANDLEIDING 

 ...............................52-73

        

Manufacturer’s Plate for     RAIS 700

         Plaque signalétique de       RAIS 700
         Merkplaatje voor                RAIS 700
        

EN 13229:2001+A2:2004

Raumheizer für feste Brennstoffe

Appliance fired by wood

Poêle pour combustibles solides

Produced at: 

RAIS A/S, Industrivej 20, 9900 Frederikshavn, Danmark

     VKF-NR:

      XXXXX

    Bauart: 2

15a B-VG

EC.NO: 709

Anordningen må kun installeres i forbindelse med ubrændbart materiale.

AFSTAND TIL BRÆNDBART, BAGVÆG

ABSTAND ZU BRENNBAREN BAUTEILEN, HINTEN

DISTANCE TO COMBUSTIBLE BACK WALL

DIST. ENTRE COMPOSANTS COMBUSTIBLES, ARRIÈRE

AFSTAND TIL BRÆNDBART, SIDEVÆG

ABSTAND ZU BRENNBAREN BAUTEILEN, SEITE

DISTANCE TO COMBUSTIBLE SIDE WALL

DISTANCE ENTRE COMPOSANTS COMBUSTIBLES, COTÉ

AFSTAND TIL BRÆNDBART, MØBLERING

ABSTAND VORNE ZU BRENNBAREN MÖBELN

DISTANCE TO FURNITURE AT THE FRONT

DISTANCE ENTRE COMPOSANTS COMBUSTIBLES, DEVANT
CO EMISSION

CO EMISSION IN DEN VERBRENNUNGSPRODUKTEN

EMISSION OF CO IN COMBUSTION PRODUCTS

EMISSION CO DANS LES PRODUITS COMBUSTIBLES

NOMINEL EFFEKT / HEIZLEISTUNG /

THERMAL OUTPUT / PUISSANCE CALORIFIQUE:

RØGGASTEMPERATUR / ABGASTEMPERATUR /

FLUE GAS TEMPERATURE / TEMPÉRATURE DES GAZ DE FUMÉE:

VIRKNINGSGRAD / ENERGIEEFFIZIENZ /

ENERGY EFFIENCY /EFFICACITÉ ÉNERGÉTIQUE:

DK: Brug kun anbefalede brændsler. Følg instrukserne i brugermanualen. 

Anordningen er egnet til røggassamleledning og intervalfyring.

 

DE: Lesen und befolgen Sie die Bedienungsanleitung.

Zeitbrandfeuerstätte. Nur empfohlene Brennstoffe einsetzen.

  

UK: Fuel types (only recommended) Follow the installation and 

operating instruction manual. Intermittent operation.

 

F: Remarque: Veillez lire et observer les instructions du mode d'emploi. 

Foyer à durèe de combustion limitèe, homologué pour cheminée à 

connexions multiples. Utiliser seulement les combustibles recommandés.

Hergestellt für /Produced for:
ATTIKA FEUER AG, Brunnmatt 16, CH-6330 Cham / RAIS A/S, Industrivej 20, DK-9900 Frederikshavn

 

STØV / STAUB / 

DUST / POUSSIÈRES:

DK: 8 mg/Nm³ / DE:  8 mg/Nm³

UK: 8 mg/Nm³ / FR:  8 mg/Nm³

DK: 268°C / DE: 268°C 

UK: 268°C / FR: 268°C
DK: 5,2 kW / DE: 5,2 kW 

UK: 5,2 kW / FR: 5,2 kW 
DK: 80% / DE: 80%

UK: 80% / FR: 80%

DK: BRÆNDE

DE: HOLZ

UK: WOOD

FR: BOIS

DK: SE BRUGERVEJLEDNING

DE: SIEHE BEDIENUNGSANLEITUNG

UK: SEE USER MANUAL

FR: CONSULTEZ LE GUIDE DE L'UTILISATEUR

DK: SE BRUGERVEJLEDNING

DE: SIEHE BEDIENUNGSANLEITUNG

UK: SEE USER MANUAL

FR: CONSULTEZ LE GUIDE DE L'UTILISATEUR
DK:700 mm/SE BRUGERVEJLEDNING

DE:700 mm/SIEHE BEDIENUNGSANLEITUNG

UK:700 mm/SEE USER MANUAL

FR:700 mm/CONSULTEZ LE GUIDE DE L'UTILISATEUR

DK: 0,1%

DE: 0,1% / 1250 mg/nm³

UK: 0,1%

FR: 0,1%

15

RAIS 700

 

CE LABEL

RAIS 700

Summary of Contents for 700

Page 1: ...ENGLISH RAIS manual for RAIS 700 1 U s e r m a n u a l M a n u e l d u t i l i s a t e u r G e b r u i k e r s h a n d l e i d i n g R A I S 7 0 0...

Page 2: ...TURE DES GAZ DE FUM E VIRKNINGSGRAD ENERGIEEFFIZIENZ ENERGY EFFIENCY EFFICACIT NERG TIQUE DK Brug kun anbefalede br ndsler F lg instrukserne i brugermanualen Anordningen er egnet til r ggassamlelednin...

Page 3: ...1 3 2 5 7 6 4 Position 1 Position 1 Stand 1 Position 2 Position 2 Stand 2 Position 3 Position 3 Stand 3...

Page 4: ...mon sense both environmentally and economically 1 Effective lighting Use dry brushwood kindling and possible a piece of news paper Open the air damper so plenty of air is fed to the stove and the gase...

Page 5: ...EY 7 8 VENTILATION 9 INSTALLATION 10 11 INSTALLATION DISTANCE 12 17 FUEL 18 19 REGULATION OF COMBUSTION AIR 19 USING THE WOOD BURNING STOVE 20 ADJUSTMENT OF AIR DAMPER 20 CONTROL 20 FIRST USAGE 20 IMP...

Page 6: ...urning stove it is important that you read the manual thoroughly before installing and using it In the case of warranty coverage and for general queries regarding your wood burning stove it is importa...

Page 7: ...idth depth height mm 562 289 300 Recommended amount of wood when fuelling kg Distributed on 2 3 logs of wood approx 25 cm 1 8 Min uptake Pascal 12 Weight kg 125 Efficiency 80 Particles after NS3058 30...

Page 8: ...installation of this heating appliance is governed by the Health and Safety at Work Act 1974 It is the responsibility of the installer to ensure that all requirements of this Act are met during the i...

Page 9: ...en in BS 5854 1980 may be used as the basis for deciding whether a particular chimney design will provide sufficient draught The outlet from the chimney should be above the roof of the building in acc...

Page 10: ...that there is excessive draught in the chimney then either an adjustable flue damper or alternatively a draught stabiliser should be fitted The adjustable flue damper should not close off the flue ent...

Page 11: ...LISH RAIS manual for RAIS 700 11 Ventilation make the best possible use of the inserts The stove is equipped with four convection air outlet which may be connected with suit able air ducts to other ro...

Page 12: ...of solid fuel appliances The floor structure must be able to carry the weight of the wood burning stove as well as the weight of a chimney if necessary When you choose where to set up your RAIS wood...

Page 13: ...e on the flue outlet inside the convection box It is important that there are no leakage between the flue pipe and the stove It is re commended to seal the connection by suitable gasket or compound In...

Page 14: ...min mm Distance 300 material min mm Distance to combustible e g side wall 200 material min mm Distance to combustible e g door frame 100 Min mm 100 Min mm 300 Min mm Min convection area above the stov...

Page 15: ...uted 300 material min mm Distance to combustible 850 min mm Clearance 400 min mm Distance 110 Min mm 50 Min mm 50 Min mm 200 area min mm Distance to combustible e g door frame 300 area min mm Distance...

Page 16: ...bustible material min 300 mm Min convection area below the stove 400 cm may be distributed Distance to non combustible material 0 mm 10mm recomended Distance to non combustible material 0 mm 10mm reco...

Page 17: ...Steel expands when heated Aqua panel Super isol Brick wall 545 Min mm 850 Min mm 415 Min mm 5 Min mm 1025 Min mm 590 Min mm 545 Min mm 5 Min mm 581 Min mm 925 Min mm 545 Min mm 5 Min mm Note For reas...

Page 18: ...ENGLISH RAIS manual for RAIS 700 18 J J J J...

Page 19: ...e stove and 150 mm to each side measuring from the door of the combustion chamber The clearance distances to combustible material beneath surrounding or upon the hearth and walls adjacent to the heart...

Page 20: ...impregnated wood wood with a synthetic surface painted refuse wood chipboard plywood domestic waste paper bri quettes and pit coal as this will produce malodorous smoke which could be poisonous When...

Page 21: ...is pre heated through the side channels and then emitted as hot scav enging air onto the glass The hot air rinses the glass and keeps it soot free The tertiary channel which can be seen at the the to...

Page 22: ...hat the wood burning stove can get accustomed to the high temperature This gives the best start and any damage is avoided Be aware that a strange but harmless odour and smoke concoction may emanate fr...

Page 23: ...e fire out or eject and safely dispose of fuel from the appliance c Check for flue or chimney blockage and clean if required d Do not attempt to relight the fire until the cause of the fume emission h...

Page 24: ...udvikling bn luftspj ldet helt samt eventuel l ge p klem eller t nd op forfra Hvis br ndet kun ulmer eller ryger og der tilf res for lidt luft udvikles der uforbr ndte r ggasser R ggas kan ant ndes og...

Page 25: ...n the chimney 3 This means that there definitely is a draught in the chimney and you avoid smoke in the room Light the fire 4 and shut the door leaving the door ajar approx 10 15 mm 5 When the flames...

Page 26: ...n chamber Scrape shovel the ash out and store it in a non flammable container until it has cooled down You can dispose of ash with your normal household waste REMEMBER Never remove all the ashes from...

Page 27: ...culit Handle these parts carefully Lift the baffle plate a little and push towards one of the sides Remove the baffleplate by lifting it upwards and tilting on end Gently take out the baffle plate Now...

Page 28: ...chimney draught too large 22 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for room ventilation unclean smok...

Page 29: ...ributor See the following spare parts diagrams for the individual products Reservedelstegning RAIS 700 Pos Antal Varenr Beskrivelse 1 1 7091401SORT Complete cover 2 1 7092090 Steel door 3 1 7091090 Gl...

Page 30: ...RAIS A S Industrivej 20 DK 9900 Frederikshavn www rais dk...

Page 31: ......

Page 32: ......

Reviews: