Page 1: ...500 IMPORTANT INFORMATION On first lighting the stove you must be careful not to touch the painted surfaces and it is MOST IMPORTANT that the door is kept slightly ajar in order for the door seal and...

Page 2: ...Manual for Rais 500 2 Rais 500 January 2014...

Page 3: ...ION 18 MOUNTING DISTANCE 20 PLACEMENT OF SUPPORT ROD 2G 3G MODELS 27 INSTALLATION DISTANCEFOR COMBUSTIBLE WALLS 28 OPERATING INSTRUCTIONS 29 FUEL 29 DRYING AND STORAGE 30 REGULATING THE COMBUSTION AIR...

Page 4: ...of water Asbestos This stove contains no asbestos If there is a possibility of disturbing any asbestos in the course of installation then please seek specialist guidance and use appropriate protective...

Page 5: ...g the stove to the chimney but is not suitable for using for the complete chimney The chimney and connecting fluepipe must have a minimum diameter of 150 mm and its dimension should be not less than t...

Page 6: ...liner Electrical Services The installation of any electrical services during the installation of this appliance must be carried out by a registered competent electrician and in accordance with the re...

Page 7: ...e appliance If the alarm sounds unexpectedly follow the instructions given under Warning Note above Use of fireguard When using the stove in situations where children aged and or infirm persons are pr...

Page 8: ...for Refuelling details Operation with door left open Operation with the door open can cause excess smoke The appliance must not be operated with the appliance door left open except as directed in the...

Page 9: ...allow fuel to spill over the top of the front fire bars Take care that fuel does not project over the front fire bars or damage to the glass may be caused when the doors are closed Flueway cleaning I...

Page 10: ...Manual for Rais 500 10 Rais 500 January 2014...

Page 11: ...wood when fuelling kg Based on 2 3 logs of wood approx 25cm 1 8 Min uptake Min draught Pascal 12 Weight kg 110 Efficiency 80 Particles after NS3058 3059 g kg 1 8 Dust measured according to Din mg Nm3...

Page 12: ...Manual for Rais 500 12 Rais 500 January 2014...

Page 13: ...for deciding whether a particular chimney design will provide sufficient draught Please Note this appliance has been tested by the manufacturers and works on a 3m straight flue The outlet from the chi...

Page 14: ...Manual for Rais 500 14 Rais 500 January 2014...

Page 15: ...Manual for Rais 500 15 Rais 500 January 2014 Flue Outlet Positions...

Page 16: ...Manual for Rais 500 16 Rais 500 January 2014...

Page 17: ...Manual for Rais 500 17 Rais 500 January 2014...

Page 18: ...Manual for Rais 500 18 Rais 500 January 2014...

Page 19: ...Manual for Rais 500 19 Rais 500 January 2014...

Page 20: ...Manual for Rais 500 20 Rais 500 January 2014 Insulate ceiling if necessary...

Page 21: ...Manual for Rais 500 21 Rais 500 January 2014 Distance to non combustible material 50mm min Distance to non combustible material 50mm min Insulate ceiling if necessary...

Page 22: ...Manual for Rais 500 22 Rais 500 January 2014...

Page 23: ...Manual for Rais 500 23 Rais 500 January 2014...

Page 24: ...Manual for Rais 500 24 Rais 500 January 2014 To guide the hot air out of the grilles we recommend that a non combustible plate is installed just above the holes...

Page 25: ...Manual for Rais 500 25 Rais 500 January 2014 To guide the hot air out of the grilles we recommend that a non combustible plate is installed just above the holes...

Page 26: ...Manual for Rais 500 26 Rais 500 January 2014 To guide the hot air out of the grilles we recommend that a non combustible plate is installed just above the holes...

Page 27: ...Manual for Rais 500 27 Rais 500 January 2014...

Page 28: ...Manual for Rais 500 28 Rais 500 January 2014...

Page 29: ...Manual for Rais 500 29 Rais 500 January 2014...

Page 30: ...Manual for Rais 500 30 Rais 500 January 2014...

Page 31: ...Manual for Rais 500 31 Rais 500 January 2014...

Page 32: ...Manual for Rais 500 32 Rais 500 January 2014...

Page 33: ...Manual for Rais 500 33 Rais 500 January 2014 1 3 5 2 4 6...

Page 34: ...Manual for Rais 500 34 Rais 500 January 2014...

Page 35: ...Manual for Rais 500 35 Rais 500 January 2014...

Page 36: ...Manual for Rais 500 36 Rais 500 January 2014...

Page 37: ...Manual for Rais 500 37 Rais 500 January 2014...

Page 38: ...e and insulate the chimney Use a qualified installer HETAS or building control Spend time with your stove get to know how your stove and chimney works Don ts Overload your stove with wood Overfire all...

Page 39: ...Manual for Rais 500 39 Rais 500 January 2014 5111790 Air box 511480490 Convection grate 511480890 Convection grate...

Page 40: ...Manual for Rais 500 40 Rais 500 January 2014...

Page 41: ...Manual for Rais 500 41 Rais 500 January 2014 Spare Parts...

Page 42: ...Manual for Rais 500 42 Rais 500 January 2014...

Page 43: ...Manual for Rais 500 43 Rais 500 January 2014...

Page 44: ...for Rais 500 44 Rais 500 January 2014 U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www robeys co uk Jun...

Reviews: