Interruption of operation
Smoke spillage around door:
Could be due to too low draught in the chimney <12Pa
- Check whether the flue or chimney is blocked
- check whether the extraction hood is switched on; if it is, switch it off and open a win-
dow/door in the proximity of the stove for a short while.
Soot on glass:
Could be because the firewood is too wet.
- make sure that the stove is heated properly when firing up, prior to closing the door
Could be because the damper regulation is too low.
A stove burning too strong could be caused by:
- leak around the door seal
- chimney draught too large >22 Pa, draught control regulator should be installed.
A stove burning too weakly could be caused by:
- too little firewood
- too little air supply for room ventilation
- unclean smoke channels
- leaky chimney
- leakage between chimney and flue
If your stove continues to malfunction, we recommend that you contact your RAIS dis-
tributor or chimney sweep.
IMPORTANT!!
To ensure safe burning there must be clear yellow flames or clear embers
at all times. The firewood should not be smoldering. Therefore you should never com-
pletely cut off the air supply.
WARNING!!
In case of chimney fire:
- shut off all air supply on the wood burning stove
- contact the fire department
- never attempt to put out fire with water!
- afterwards, you should ask your chimney sweeper to check the stove and chimney
Summary of Contents for 500
Page 3: ......
Page 15: ...Dansk RAIS manual til RAIS 500 13 A A A A Opstillingsafstand indsats ikke br ndbart panel...
Page 25: ...4 6 1 2 3 5...
Page 32: ...11 13 14 15 12 16...
Page 52: ...English RAIS manual for RAIS 500 46 Placement of support rod 2G 3G model Support rod...
Page 59: ...4 6 1 2 3 5...
Page 66: ...11 13 14 15 12 16...
Page 82: ...Norsk RAIS manual til RAIS 500 1 Plassering av st ttestangen 2G 3G model St ttestang...
Page 88: ...4 6 1 2 3 5...
Page 95: ...11 13 14 15 12 16...
Page 111: ...Svenska RAIS handbok til RAIS 500 99 Placering av st dst ngen 2G 3G model St dst ng...
Page 117: ...4 6 1 2 3 5...
Page 124: ...11 13 14 15 12 16...
Page 140: ...Suomenkielinen RAIS k ytt ohje RAIS 500 125 Sijoittaminen tukitangon 2G 3G model Tukitangon...
Page 146: ...4 6 1 2 3 5...
Page 153: ...11 13 14 15 12 16...
Page 174: ...4 6 1 2 3 5...
Page 181: ...11 13 14 15 12 16...
Page 203: ...4 6 1 2 3 5...
Page 210: ...11 13 14 15 12 16...