background image

ENGLISH       

                          RAIS - manual for Rais 2:1 

April 2014 

 

 

 

2:1 

Nominal output (kW): 

Min. / Max. output (kW): 

3-9 

Heating area (m

2

): 

Ca. 60-135 

Size, width/depth/height (mm): 

807 / 474 / 909 

without socket 

Combustion chamber  width/depth/height (mm). 

500 / 244 / 374 

Recommended amount of wood when fuelling (kg) 
(Based on 2  -  3 logs of wood approx. 25cm) 

2.1 

Min. uptake / Min. draught (Pascal): 

-12 

Weight (kg): 

140 

Smoke gas mass flow (g/s): 

5.1 

Smoke gas temperature (°C): 

297 

Intermittent operation: 

Fuelling should 

be undertaken 

 within 3 hours  

Efficiency ( % ) 

79 

Particles after NS3058/3059 (g/kg) 

3.6 

Dust measured according to Din+ (mg/Nm

3

 

Specifications 

Please Note, this appliance has been tested by the manufacturers and works on a 

3m straight flue. 

Summary of Contents for 2:1

Page 1: ...S 2 1 IMPORTANT INFORMATION On first lighting the stove you must be careful not to touch the painted surfaces and it is MOST IMPORTANT that the door is kept slightly ajar in order for the door seal an...

Page 2: ...ENGLISH RAIS manual for Rais 2 1 2 April 2014...

Page 3: ...LATION DISTANCE TO NON COMBUSTIBLE WALL 14 15 INSTALLATION DISTANCE TO COMBUSTIBLE WALL 16 17 GENERAL INSTALLATION 18 FOR THE INSTALLER 19 OPERATING INSTRUCTIONS 20 FUEL 20 DRYING AND STORAGE 21 REGUL...

Page 4: ...We therefore recommend that you note down the number in the table below The production number is located at the back of the stove at the bottom Warranty Your Rais wood burning stove comes with a 5 yea...

Page 5: ...nt of wood when fuelling kg Based on 2 3 logs of wood approx 25cm 2 1 Min uptake Min draught Pascal 12 Weight kg 140 Smoke gas mass flow g s 5 1 Smoke gas temperature C 297 Intermittent operation Fuel...

Page 6: ...hout the entire room The cold air is sucked in at the base of the stove and up through the convection channel which runs along the stove s combustion chamber The heated air comes out at the top of the...

Page 7: ...The installation of this heating appliance is governed by the Health and Safety at Work Act 1974 it is the responsibility of the installer to ensure that all requirements of this Act are met during th...

Page 8: ...e liner must be used in accordance with Building Regulations Approved Document J Any existing chimney must be clear of obstruction and should have been swept clean immediately before the installation...

Page 9: ...ovision e g easily accessible soot door or doors must be provided for sweeping the chimney and connecting fluepipe You should also familiarise yourself with the draught conditions for chimneys with 2...

Page 10: ...not blocked Building Regulations Approved Document J gives specific guidance on the required permanent ventilation into the room for combustion air of solid fuel appliances The floor structure must b...

Page 11: ...ments using the levelling bolts in the base Remove the frame and door from the stove Be careful not to damage the glass or paint Leave the protective tape and plastic on the handles during installatio...

Page 12: ...ENGLISH RAIS manual for Rais 2 1 12 April 2014...

Page 13: ...ENGLISH RAIS manual for Rais 2 1 13 April 2014...

Page 14: ...ENGLISH RAIS manual for Rais 2 1 14 April 2014 Insulation ability such as Aqua panel coefficient of thermal conductivity 0 36 W mk or better Please use metal stud...

Page 15: ...ENGLISH RAIS manual for Rais 2 1 15 April 2014...

Page 16: ...ENGLISH RAIS manual for Rais 2 1 16 April 2014 The two rows of bricks beneath the stove is limited to a max depth of 75mm...

Page 17: ...ENGLISH RAIS manual for Rais 2 1 17 April 2014...

Page 18: ...uld always be installed on a non combustible hearth of a size and construction that is in accordance with the provisions of the current UK Building Regulations Approved Document J If the stove is to b...

Page 19: ...d appliance connections to the chimney Ensure that the appliance and chimney flue are functioning correctly before finally handing over to the user Read the later parts of this manual for guidance on...

Page 20: ...f the combustion chamber minus 50 60 mm Stoking with wet firewood causes both soot environmental pollution and bad fuel economy Freshly cut wood contains approx 50 70 water and is thoroughly unsuitabl...

Page 21: ...chamber and is pre heated through the side channels and then emitted as hot scavenging air onto the glass The hot air rinses the glass and keeps it soot free The tertiary channel which can be seen at...

Page 22: ...oxi mately 19cm height Adjusting the air damper The damper has 3 settings Position 1 The damper is almost closed meaning that there is a minimal air intake Position 2 Pull push the lever until the fir...

Page 23: ...on The stove gets very hot when in use always wear protective gloves when tending the stove If the stove has not been used for a while follow the steps as if you were using it for the first time IMPOR...

Page 24: ...lways opened prior to lighting the stove Tips before firing up Open a door or window close to the wood burning stove If there is storm in the stove coming from the chimney it is advisable to place a s...

Page 25: ...a good bed of glowing embers add 2 3 pieces of wood Leave the door ajar until the fire has caught properly then close the door Damper see adjustment of the damper After approximately 5 minutes or when...

Page 26: ...ustion chamber Scrape shovel the ash out and store it in a non flammable container until it has cooled down You can dispose of ash with your normal household waste or recycle on the garden REMEMBER Ne...

Page 27: ...he sides Remove the baffle plate by lifting it upwards and tilting on it s end The other end is lowered and the baffle plate turned a little Gently take out the baffle plate Now there is a clear view...

Page 28: ...ney draught too large 22 Pa draught control regulator should be installed A stove burning too weakly could be caused by too little firewood too little air supply for the room ventilation dirty smoke c...

Page 29: ...parts other than those recommended by RAIS are used the warranty is voided All replacement spare parts can be purchased from your RAIS distributor stockist See the following spare parts diagrams for...

Page 30: ...ef Quantity Item No Description 1 2 9101401SORT Complete front 2 2 9101090 Door left hinged 2 9101090H Door right hinged 9101090L Door left hinged locked 9101090LH Door right hinged locked 9101032 Too...

Page 31: ...ENGLISH RAIS manual for Rais 2 1 31 April 2014...

Page 32: ...ENGLISH RAIS manual for Rais 2 1 32 April 2014...

Page 33: ...ENGLISH RAIS manual for Rais 2 1 33 April 2014...

Page 34: ...ENGLISH RAIS manual for Rais 2 1 34 April 2014...

Page 35: ...ENGLISH RAIS manual for Rais 2 1 35 April 2014...

Page 36: ...RAIS manual for Rais 2 1 36 April 2014 U K Distributor Robeys Ltd Riverside Goods Road Belper Derbyshire England DE56 1UU Tel 01773 820940 Fax 01773 820477 E Mail info robeys co uk www robeys co uk Ap...

Reviews: