background image

  

 

 

 

9

 

 

 

 

 

RainWise Multi Display Users Guide 

2014 Revision 

 

2)

 

Setup Mode 

 
 

 Enter the setup mode:

      Press      

                     

then                   

 

 
 
All the displays will go blank and the MIN and MAX lights will be flashing.   
 
In the setup mode you can change one or all of the parameters. Select the parameter you wish to 
change by pressing the appropriate button. Once you have changed that parameter, you will be 
returned to the Setup mode. Choose another parameter or press 

SELECT

 to exit back to normal 

operation.   
 

2.1)

 

Time/Date 

 

Be sure you are in the setup mode.  The max and min LEDs should be flashing.

 

 

Press the 

TIME

 button (press on the word TIME). The current time will appear.  

 

Press the 

MAX

 button once. Use the 

MIN

 and 

MAX 

buttons to select 12 hour or 24 hour 

format. Press 

SELECT

 to accept.  

 

Press the 

MAX

 button once.  The hour will now be flashing. To change the hour press 

the 

MAX

 button to increase and 

MIN

 to decrease it. The hours are shown in 24-hour 

military time.   

 

Press the 

SELECT

 button when the hour is correct. The minutes will now flash. Repeat 

the same steps as with the hour adjustment. 

 

Press 

SELECT 

when done. Note that the seconds are set to zero when 

SELECT

 is 

pressed.  

 

The month will flash. Set the month in the same way. 

 

Press 

SELECT 

when done. 

 

The day will flash. Set the day in the same way. 

 

Press 

SELECT 

when done.  

 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for Weather Oracle MKIII

Page 1: ...Weather Oracle MKIII MKIII LR User s Guide Rev Date 7 08 14...

Page 2: ...pyright 2014 by RainWise Inc All rights reserved No part of this work may be reproduced in any form except by written permission of the publisher All rights of translation are reserved RainWise Multi...

Page 3: ...ure 10 2 22 Wind Speed 10 2 23 Rainfall 10 2 24 Barometer 11 2 3 Brightness 11 2 4 Automatic Toggling of Displays 11 2 5 Fine Tuning Temperatures 12 2 6 Setting Temperature Characters 12 3 Operating t...

Page 4: ...4 RainWise Multi Display Users Guide 2014 Revision 3 71 Lock Display 14 3 72 Unlock Display 15 4 Diagnostic Mode 15 4 1 Factory Reset 16 5 Product Support 16 5 1 Contact Information 17 5 2 Warranty 17...

Page 5: ...e power source 9 volts DC 500mA to the radio transmitter Only use the power source provided with this multi display oracle since it is different from the standard oracle display Do not attempt to use...

Page 6: ...option for battery backup There are slots in the back for 5 AAA alkaline batteries in all wooden frame units Metal Framed displays do not have battery backup option Refer to the diagram on the back of...

Page 7: ...ernal temperature sensor will record the exact temperature at the mounting location For example if the unit is mounted on an exterior wall the reading will be affected by the temperature of the wall w...

Page 8: ...Keep pressing SELECT to Exit Make a parameter toggle SELECT parameter button Lock display MAX SELECT HUMIDITY Press HUMIDITY button to toggle to Loc SELECT twice when done Unlock display HUMIDITY and...

Page 9: ...ld be flashing Press the TIME button press on the word TIME The current time will appear Press the MAX button once Use the MIN and MAX buttons to select 12 hour or 24 hour format Press SELECT to accep...

Page 10: ...s SELECT when done 2 22 Wind Speed Be sure you re in the setup mode The max and min LED s should be flashing Press WIND SPEED press on the words WIND SPEED The wind speed display will show U 0 U 1 U 2...

Page 11: ...t OPTIONAL To display the actual offset value press MAX and MIN at the same time You can set this back to zero by pressing the SELECT key You must be holding down both MAX and MIN when you do this Pre...

Page 12: ...rrect Press MAX to increase the offset and MIN to decrease it Press MAX and MIN at the same time to display the actual offset value You can set this back to zero by pressing the SELECT key You must be...

Page 13: ...nge a display s status press the button below the desired display for example TIME This will toggle the status Press SELECT when done Press SELECT again to exit the setup mode 3 3 Displaying Minimums...

Page 14: ...LECT The MAX and MIN LEDs should be flashing Press RAINFALL The current units will be either U 0 or U 1 Press SELECT Adjust the CUR counter using the MAX and MIN buttons Press SELECT when done Press S...

Page 15: ...ults Enter the diagnostic mode Press then BE SURE TO RECORD THE FOLLOWING VALUES BEFORE RESETTING YOUR DEVICE HUMIDITY shows the software versions of the display and sensor unit The two digits on the...

Page 16: ...nce the button has been pressed the unit will reset The EEPROM memory is tested this may take a few seconds If the process is halted and the time display shows bad contact the RainWise Service Departm...

Page 17: ...Wise Inc will not pay for warranty service performed by a non authorized repair service and will not reimburse the consumer for damage resulting from warranty service performed by a non authorized rep...

Reviews: