background image

RWH-FL01 Float Switch                  

www.RainWaterHarvesting.co.uk

   

©

 2010 

 

 
 

WIRING C)  One pump turns OFF when float rises and another pump turns on 

 
There are some specialist applications where the float switch can control two pumps. For 
example, one pump could be permanently pumping from one tank, and when this first 
tank is empty a second pump starts pumping from another source. Apply the detail of the 
two basic functions A and B above. 
 

WIRING D)  General information and warnings applicable to all functions 

 
i) 

The float switch cable can carry 230 Volts AC or other voltages at DC (direct 

current) 
ii) 

In the case of 230 Volts AC applications, ensure that there is no risk of the wire 

fraying and insulation breaking down. Ensure that connections are secure, dry and well 
insulated from short circuit and from contact with a maintenance person. 
iii) 

Do not connect the earth pin of the mains plug to any lead of the float switch. 

Only the earth lead of the pump (or solenoid valve or other appliance) should be 
connected to the earth pin of the mains plug. 
iv) 

The pump or appliance must be earthed as showed by the yellow and green 

striped cables in the wiring diagrams above. 
 
 

F) 

TECHNICAL DATA 

 
Rated voltage  

 

 

125 to 250 volts AC or up to 24 volts DC 

Maximum current 

 

 

16 amps 

Frequency 

 

 

 

50-60 Hz 

Maximum operating temperature  50°C 
Protection Grade 

 

 

IP68 hermetically-sealed 

 
 

G) 

WARRANTY STATEMENT 

 
In the case of manufacturing faults, the product will be repaired or replaced free of 
charge within one year from purchase, but no liability can be assumed by the 
manufacturer for damage caused to any other appliance or person as a result of such 
fault. The warranty does not apply to any defects caused by misuse, improper storage, 
incorrect installation or other lack of diligence and care by the client. The standard 
warranty terms of RainWater Harvesting Limited are applicable and they can be viewed 
at 

www.RainWaterHarvesting.co.uk

 
 
This float switch Product ID: RWH-FL01 is manufactured outside the European Union for, 
and imported by, RainWater Harvesting Limited of Peterborough UK. 
 
These instructions and images are the property of RainWater Harvesting Limited © 2010 
and all rights are reserved. The information is provided for the benefit of our clients and 
no reproduction is permitted without our agreement in writing. 
 
 
 

Distributed by RainWater Harvesting Limited,  

Unit A, Harrier Park, Southgate Way, Orton Southgate,  

Peterborough PE2 6YQ 

Phone 01733 405100 - Fax 01733 230996 

Email 

[email protected]

 

Web site www.RainWaterHarvesting.co.uk  

Float Switch instructions Jan2010 MB 

RWH064 float_switch_instructions.pdf V2 

 