RWH-FL01 Float Switch
www.RainWaterHarvesting.co.uk
©
2010
3
WIRING C) One pump turns OFF when float rises and another pump turns on
There are some specialist applications where the float switch can control two pumps. For
example, one pump could be permanently pumping from one tank, and when this first
tank is empty a second pump starts pumping from another source. Apply the detail of the
two basic functions A and B above.
WIRING D) General information and warnings applicable to all functions
i)
The float switch cable can carry 230 Volts AC or other voltages at DC (direct
current)
ii)
In the case of 230 Volts AC applications, ensure that there is no risk of the wire
fraying and insulation breaking down. Ensure that connections are secure, dry and well
insulated from short circuit and from contact with a maintenance person.
iii)
Do not connect the earth pin of the mains plug to any lead of the float switch.
Only the earth lead of the pump (or solenoid valve or other appliance) should be
connected to the earth pin of the mains plug.
iv)
The pump or appliance must be earthed as showed by the yellow and green
striped cables in the wiring diagrams above.
F)
TECHNICAL DATA
Rated voltage
125 to 250 volts AC or up to 24 volts DC
Maximum current
16 amps
Frequency
50-60 Hz
Maximum operating temperature 50°C
Protection Grade
IP68 hermetically-sealed
G)
WARRANTY STATEMENT
In the case of manufacturing faults, the product will be repaired or replaced free of
charge within one year from purchase, but no liability can be assumed by the
manufacturer for damage caused to any other appliance or person as a result of such
fault. The warranty does not apply to any defects caused by misuse, improper storage,
incorrect installation or other lack of diligence and care by the client. The standard
warranty terms of RainWater Harvesting Limited are applicable and they can be viewed
at
www.RainWaterHarvesting.co.uk
.
This float switch Product ID: RWH-FL01 is manufactured outside the European Union for,
and imported by, RainWater Harvesting Limited of Peterborough UK.
These instructions and images are the property of RainWater Harvesting Limited © 2010
and all rights are reserved. The information is provided for the benefit of our clients and
no reproduction is permitted without our agreement in writing.
Distributed by RainWater Harvesting Limited,
Unit A, Harrier Park, Southgate Way, Orton Southgate,
Peterborough PE2 6YQ
Phone 01733 405100 - Fax 01733 230996
Web site www.RainWaterHarvesting.co.uk
Float Switch instructions Jan2010 MB
RWH064 float_switch_instructions.pdf V2