background image

3

Congratulations

on your purchase of a RainSoft water filtration

system.

This Owner’s Manual is designed to assist with the operation, mainte-
nance, and installation of the QRS system. It is our sincere hope that
this manual is clear, concise, and helpful to you as a new owner.

Questions?

If you have any questions regarding the installation, oper-

ation, or servicing of this system, please contact your local RainSoft
Dealer. Your local RainSoft Dealer is familiar with your particular
water conditions, and is able to address your concerns promptly and
efficiently.

Operational Specifications

Plumbing

3/4

to 1

1/4

 

inch I.D.

Water Pressure

20 psi – 120 psi (138 kPa – 828 kPa)

Operating Temperatures

40°F– 100°F (4.4°C – 37.8°C)

Bypass Valve

The bypass valve enables you to bypass the system in situations of:
emergency leaks in the equipment, service calls.

Existing Plumbing Conditions

Plumbing should be free from lime and/or iron buildup. Piping that
contains large amounts of lime and/or iron should be replaced.

Additional Specifications

• The inlet water should be free of iron and turbidity.

• Do not install this system where water is microbiologically unsafe or

of unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used on
disinfected waters that may contain filterable cysts.

• This system must be installed in accordance with all applicable state

and local laws and regulations.

• This system must be installed in an area not affected by extreme

heat, cold, or the elements. The selected installation area must be
adequate for easy service and accessibility.

• The installation must be on a cold water supply.

Data Chart

QRS

MODEL

QUANTITY

OF MEDIA

SERVICE

FLOW

RATE

PSI DROP@

SERVICE

FLOW

RATE

CAPACITY

FOR VOC

REDUCTION

CAPACITY FOR

AESTHETIC

CHLORINE

REDUCTION

844 H

0.9 cu.ft.

6.0 gpm

3 psi

20,250 gallons

90,000 gallons

1044 H

1.4 cu.ft.

8.0 gpm

3 psi

31,500 gallons

140,000 gallons

1054 H

2.0 cu.ft.

10.0 gpm

5 psi

45,000 gallons

200,000 gallons

1354 H

4.0 cu.ft.

12.0 gpm

6 psi

83,250 gallons

370,000 gallons

Summary of Contents for QRS SERIES

Page 1: ...7 9400 or 1 800 860 7638 www rainsoft com The QRS H series is tested and certified by the WQA to NSF ANSI 42 and 53 for the specific per formance claims as verified and substantiated by test data See...

Page 2: ...Operational Specifications 3 Product Certification Information 4 Installation Instructions 4_5 System Start Up 6 Maintenance Requirements 6 Troubleshooting Guide 7 Exploded View and Parts List 8 9 War...

Page 3: ...that contains large amounts of lime and or iron should be replaced Additional Specifications The inlet water should be free of iron and turbidity Do not install this system where water is microbiolog...

Page 4: ...o the system Set the pressure regulator at a maximum of 60 psi which is the optimum operating pressure 4 Locate a Site for the System There is only one requirement needed for a site the main water sou...

Page 5: ...to another location As a last resort install a heat trap or check valve If this causes water hammer install a water hammer suppressor Connect the yoke to the bypass valve Install the flow restrictor...

Page 6: ...et 3 Test the Water Test the water for the particular contaminant that the system is designed to remove The installation is complete and the system is ready for use Maintenance Requirements Replacing...

Page 7: ...se Solution 1 Poor water quality 2 Taste Odor 1 The raw water has changed 1 Call your RainSoft Dealer for a new water analysis 1 The filter media may be exhausted 1 Call your RainSoft Dealer to replac...

Page 8: ...8 Exploded View 6 5 7...

Page 9: ...18962 RISER PIPE ASSEMBLY MODELS 844 H 1044 H MODEL 1054 H MODEL 1354 H 3 1 19777 19778 N A TANK COLLAR MODEL 844 H MODELS 1044 H 1054 H MODEL 1354 H 4 1 19574 COMPOSITE QRS HEAD 5 1 19245 QRS BYPASS...

Page 10: ...ther claims or torts Some states do not allow the exclusion or limitation of incidental or consequential damages so parts of the above limitation or exclusion may not apply to you This warranty gives...

Page 11: ...11 NOTES...

Page 12: ...ision of Aquion Water Treatment Products 2080 East Lunt Avenue Elk Grove Village Illinois 60007 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2007 RAINSOFT DIVISION...

Reviews: