background image

RainSoft Division of Aquion Water Treatment Products

2080 East Lunt Avenue

Elk Grove Village, Illinois 60007

1.847.437.9400 or 1.800.860.7638

www.rainsoft.com

The QRS H series is tested and certified by the WQA to NSF/ANSI 42 and 53 for the specific per-
formance claims as verified and substantiated by test data.  See the performance data sheet for
specific reduction claims.

Part No.: 15664
Rev: C   10/08

QRS  SERIES

WATER  TREATMENT  SYSTEM

Summary of Contents for QRS SERIES

Page 1: ...7 9400 or 1 800 860 7638 www rainsoft com The QRS H series is tested and certified by the WQA to NSF ANSI 42 and 53 for the specific per formance claims as verified and substantiated by test data See...

Page 2: ...Operational Specifications 3 Product Certification Information 4 Installation Instructions 4_5 System Start Up 6 Maintenance Requirements 6 Troubleshooting Guide 7 Exploded View and Parts List 8 9 War...

Page 3: ...that contains large amounts of lime and or iron should be replaced Additional Specifications The inlet water should be free of iron and turbidity Do not install this system where water is microbiolog...

Page 4: ...o the system Set the pressure regulator at a maximum of 60 psi which is the optimum operating pressure 4 Locate a Site for the System There is only one requirement needed for a site the main water sou...

Page 5: ...to another location As a last resort install a heat trap or check valve If this causes water hammer install a water hammer suppressor Connect the yoke to the bypass valve Install the flow restrictor...

Page 6: ...et 3 Test the Water Test the water for the particular contaminant that the system is designed to remove The installation is complete and the system is ready for use Maintenance Requirements Replacing...

Page 7: ...se Solution 1 Poor water quality 2 Taste Odor 1 The raw water has changed 1 Call your RainSoft Dealer for a new water analysis 1 The filter media may be exhausted 1 Call your RainSoft Dealer to replac...

Page 8: ...8 Exploded View 6 5 7...

Page 9: ...18962 RISER PIPE ASSEMBLY MODELS 844 H 1044 H MODEL 1054 H MODEL 1354 H 3 1 19777 19778 N A TANK COLLAR MODEL 844 H MODELS 1044 H 1054 H MODEL 1354 H 4 1 19574 COMPOSITE QRS HEAD 5 1 19245 QRS BYPASS...

Page 10: ...ther claims or torts Some states do not allow the exclusion or limitation of incidental or consequential damages so parts of the above limitation or exclusion may not apply to you This warranty gives...

Page 11: ...11 NOTES...

Page 12: ...ision of Aquion Water Treatment Products 2080 East Lunt Avenue Elk Grove Village Illinois 60007 Main Switchboard 1 847 437 9400 Customer Service 1 800 860 7638 www rainsoft com 2007 RAINSOFT DIVISION...

Reviews: