24 |
9. Replace the spark plug.
10. Move the generator to a clean, dry place for storage.
5. With the fuel shut off valve open, start the engine
and allow the generator to run until all the remaining
gasoline in the fuel lines and carburetor is consumed
and the engine shuts off.
6. Close the fuel shut off valve.
7. Change the oil.
8. Remove the spark plug and place about 1
tablespoon of oil in the spark plug opening. While
placing a clean rag over the spark plug opening,
slowly pull there coil handle to allow the engine to
turn over several times. This will distribute the oil
and protect the cylinder wall from corroding during
storage.
WARNING
Before attempting to service or troubleshoot the generator, the owner or service technician must first read the owner’s
manual and understand and follow all safety instructions. Failure to follow all instructions may result in conditions that can
lead to voiding of the EPA certification or product warranty, serious personal injury, property damage or even death.
PROBLEM
POTENTIAL CAUSE
SOLUTION
Engine is running, but no
electrical output
1. Circuit breakers are tripped.
1. Reset the circuit breakers and check for
overload condition.
2. The power cord’s plug connector is not fully
engaged in the generator’s outlet.
2. Verify plug connector is firmly engaged in the
generator’s outlet.
3. Faulty or defective power cord
3. Replace power cord.
4. Faulty or defective electrical appliance
4. Try connecting a known good appliance to
verify the generator is producing electrical power.
5. If trying 1-4 above does not solve the
problem, the cause might be the generator has
a fault.
6. Take the generator to your nearest authorized
service dealer.
Engine runs
erratic; does not hold a
steady RPM.
1. Dirty air filter
1. Clean the air filter.
2. Applied loads maybe cycling on and off
2. As applied loads cycle, changes in engine
speed may occur; this is a normal condition.
3. If trying 1-2 above does not solve
the problem, the cause might be a
fault in the generator
3. Take the generator to your nearest authorized
service dealer.
Generator suddenly
stops running.
1. Generator is out of fuel.
1. Check fuel level. Add fuel if necessary.
2. The low oil shut down switch has stopped
the engine.
2. Check oil level and add oil if necessary.
3. Too much load
3. Restart the generator and reduce the load.
4. If trying 1-3 above does not solve the
problem,the cause might be a fault in the
generator.
4. Take the generator to your nearest authorized
service dealer.
MAINTENANCE
TROUBLESHOOTING