ISSUE

POSSIBLE CAUSE

POSSIBLE SOLUTION

The Rainbow motor is not running

Rainbow not properly latched to water 

basin. Air inlet screen is plugged with 

debris.

Ensure side latches of water basin are 

locked. 

Not fi rmly plugged in.

Plug unit in fi rmly or try another outlet.

Air inlet screen is plugged with debris.

Clean off  debris thoroughly.

Automatic resetting motor protector 

has tripped.

Turn Rainbow off . Leave off  for 30 

seconds. Turn Rainbow back on.

Defective cord, switch or Rainbow.

Contact an Authorized Rainbow 

Distributor or Service Center.

Noticeably reduced airfl ow

Rainbow not correctly positioned on 

water basin.

Ensure Rainbow is properly seated and 

latched onto water basin.

Plugged hose, wand, attachment or 

Power Nozzle.

Remove obstruction from clogged area.

HEPA Neutralizer needs servicing or 

replacement.

Remove HEPA Neutralizer and clean or 

replace. 

Rainbow is running on low speed.

Turn power switch to high speed.

Separator is clogged or dirty. 

Remove separator and clean. (See 

page 10)

Unit discharges dust

Low level of water in basin.

Fill water basin to correct level.

Excessively dirty water in basin.

Replace with clean water.

Hole in HEPA Neutralizer.

Contact an Authorized Rainbow 

Distributor or Service Center.

Heavy foaming in water basin

Soapy contaminant in water basin.

Replace with clean water.

High level of water in basin.

Empty water basin and refi ll to correct 

level.

Unit discharges a musty odor

Water basin not cleaned or dumped 

after use.

Clean water basin and use Deodorant Air 

Freshener while cleaning.

Separator clogged or dirty.

Remove separator and clean. (See 

page 10)

Damp HEPA Neutralizer.

Remove HEPA Neutralizer and clean or 

replace. 

troubleshooting guide

Summary of Contents for e2-73db

Page 1: ...rainbowsystem com Rexair LLC Troy Michigan 2011 Rexair LLC R15637aQ 2 Printed in U S A...

Page 2: ......

Page 3: ...to locate a serial number on your Rainbow or Power Nozzle please contact Rexair s customer service department Ownership identification for you Warranty identification for your Distributor Assurance o...

Page 4: ...r living environment and provide years of reliable service Please take a few minutes to review this guide and familiarize yourself with your new Rainbow Cleaning System Should you have questions or ex...

Page 5: ...d knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and...

Page 6: ...tingifthewaterbasinisnotproperlylatched DONOTATTEMPTTOOVERRIDE THIS SAFETY FEATURE 14 Your Rainbow Power Nozzle contains a powerful revolving brush To avoid bodily injury the Rainbow Power Nozzle shou...

Page 7: ...Distributor 1 5 9 17 29 2 6 10 14 18 22 26 30 3 7 11 19 23 27 4 8 12 16 28 21 24 25 13 15 SERVICING OF DOUBLE INSULATED APPLIANCE In a double insulated appliance two systems of insulation are provide...

Page 8: ...t on the hose handle can be opened or closed to control airflow when vacuuming delicate items such as curtains and to make the Power Nozzle easier to push on dense carpet As you clean you can quickly...

Page 9: ...the protruding end of the dolly as shown A foot latch locks Rainbow into place To release press foot latch 4 Attach hose Press hose coupling into air inlet opening of power unit until hose clicks To r...

Page 10: ...9 1 2 1 2 1 3 5 7 2 4 6 8...

Page 11: ...cessary use the supplied Rainbow Separator Brush Wrench to loosen the nut Clean separator inside and out with soap and water using the Rainbow Separator Brush Clean and dry the flange under the separa...

Page 12: ...r into the air inlet opening before using the Rainbow as a blower or inflator The Rainbow s wide assortment of cleaning tools provide the power and versatility to clean practically everything around y...

Page 13: ...pening the Airflow ControlVent For delicate objects airflow may be further reduced TIP Attach the dusting brush to the optional extended hose to reach ceiling fan blades cornice boards and cobwebs To...

Page 14: ...ush attached surface litter and pet hair disappears like magic Use the upholstery tool on sofas chairs mattresses pillows blankets closet shelves drapes and curtains The upholstery tool may be used al...

Page 15: ...he Rainbow Power Nozzle to loosen and eliminate hairs dead skin dust mites crumbs and other particles from your bedding Caution Use of the Rainbow Power Nozzle on fine linens and soft bedding may caus...

Page 16: ...e with Clean Floor solution for superior cleaning results Ready for a Breath of Fresh Air The RainMate gives you sweet smelling air in the most practical unique and attractive manner possible Simply a...

Page 17: ...cturer prior to using the Rainbow Power Nozzle on bare hard surfaces Then test the Power Nozzle in an inconspicuous location to verify the flooring is not damaged by use The lightweight Rainbow Power...

Page 18: ...top of the Power Nozzle Next grasp the wand assembly and pull backward e Squeeze the trigger on pistol grip hose handle to activate the Power Nozzle Release trigger to turn Power Nozzle off Optional...

Page 19: ...brush roll upside down with rollers centered on top of two side tabs Slide belt over end of motor shaft b Rotate brush roll assembly forward until rollers are face up Spin brush roll toward you to po...

Page 20: ...t Dry electrical connections Resume normal operation If the corrective action does not fix the problem Contact an Authorized Distributor or Service Center Blinks 4Times Repeats Electrical connections...

Page 21: ...r Rainbow Contact an Authorized Rainbow Distributor or Service Center Noticeably reduced airflow Rainbow not correctly positioned on water basin Ensure Rainbow is properly seated and latched onto wate...

Page 22: ...omatic resetting motor protector has tripped Turn Rainbow off Leave off for 30 second Turn Rainbow back on The Power Nozzle motor is running but brush is not revolving Broken belt Disconnect power Rem...

Page 23: ...n Rainbow Clean Floor solution is ideal for thoroughly cleaning linoleum or tile floors Just spread on Clean Floor solution in and let it do the work Specially formulated for use with the Rainbow Aqua...

Page 24: ...ly through their own dealers or indirectly through independent sub Distributors and their dealers Rexair has no agreement or legal relationship with the independent resellers who acquire products dire...

Reviews: