IMPORTANT: 

Before installing this reverse osmosis system, 

make certain your water supply complies with the following 

operating specifications. Failure to do so may reduce the 

effectiveness of the system and will void the warranty.

SPECIFICATIONS

Thin Film Membrane: 
Feed Water Pressure: 
Temperature Range: 
TDS: 
Maximum Hardness

Sulfide, Iron and Manganese

Chlorine in Water Supply: 
pH Limits: 

GRO- 

75

EN

40 to 100 psi (2.75–6.9 bar)

 

40–100°F (4.4–37.7°C)

 

2000 ppm

20

 gpg (

342

 mg/L)

0 ppm <0.1 ppm

 

Less than 

3

 ppm

 

3–11

If the hardness of your water is above 

20

 gpg (

342

 mg/L), lime 

scale will build up rapidly on the membrane. Scale buildup will 
plug the membrane and make the system ineffective. We do not 
recommend these reverse osmosis systems to be used with 
water in excess of 

20

 gpg (

342

 mg/L) hardness.

A maximum total level of approximately 0.01 ppm sulfide, iron 

or manganese is permissible. See your local dealer to reduce 
these substances in your water.

PARTS INCLUDED: 

(SEE BACK OF MANUAL FOR DIAGRAM)

Pre-assembled filter system (mounting bracket, encapsulated 

membrane element, pre- and post-filter housings and pre- and 

post-filter cartridges).

• Storage tank

• Inlet supply adapter

• Drain clamp

• 1/4-inch Tubing

• Tank valve

• Chrome faucet

• Feed tubing

• 3/8-inch Tubing

SYSTEM DIMENSIONS:

Overall Dimensions:  15-inch W x 5

1

2

-inch D x 17

1

4

-inch H 

(38.1 cm W x 12.7 cm D x 43.8 cm H)

Weight: 

18 lbs. (8.16 kg)

Tank Dimensions: 

13

1

2

-inch W x 9 inch D x 9 inch H  

(34.29 cm W x 22.86 cm D x 22.86 cm H)

Tank Capacity Max: 

3.2

 gal. (10.6 L)

Tank Air Pressure Empty:  5 to 7 psi (0.34 to 0.48 bar)

Tank Weight (Full): 

28.5 lbs. (12.9 kg)

Tools and Materials Required

•  Hand or electric drill

(cordless preferred)

• (2) Adjustable wrenches
• Slotted and Phillips screwdrivers
• File
• Safety glasses
• Drill bits: 1/8", 3/16", 1/4", 3/8"

If sink does not have hole for separate faucet:

• Center punch
• Cone-shaped grinding wheel
• 1-1⁄4" hole saw or drill bit
• Safety mask

NOTE: 

All tools may not be necessary for installation. Read 

installation procedures before starting to determine 

what tools are necessary.

2 • RAIN GRO-4

75

 Installation and Operation Manual

Summary of Contents for GRO-475

Page 1: ...www rainwaterlv com Rain Water Conditioning of Las Vegas RAIN GRO 475 4 STAGE REVERSE OSMOSIS WATER FILTRATION SYSTEM INSTALLATION AND OPERATION MANUAL 702 257 PURE 7873...

Page 2: ...ter PARTS INCLUDED SEE BACK OF MANUAL FOR DIAGRAM Pre assembled filter system mounting bracket encapsulated membrane element pre and post filter housings and pre and post filter cartridges Storage tan...

Page 3: ...hould be changed at least every 12 months to avoid chlorine bypass HOW REVERSE OSMOSIS WORKS The GRO 4550 Reverse Osmosis RO System uses a semi permeable membrane to reduce dissolved salts and mineral...

Page 4: ...ches if drill bit slips C Mark point with center punch Use a 1 4 inch drill bit to drill a pilot hole through sink D Use a 11 4 inch hole saw to enlarge hole Smooth rough edges with a file 3 Mounting...

Page 5: ...e tubing Do not kink tube Cut the tubing squarely below the nut and remove the internal and external burrs B Loosen the compression nut two complete turns Insert the tubing into the nut until it stops...

Page 6: ...to quick connect fitting on the left side of system Depending on the installation the system may need to be removed from the mounting surface to access the left side of the system C Cut the tube to a...

Page 7: ...ank is filled open the faucet to flush the post filter cartridge Allow 4 to 5 minutes for all of the water to drain from the tank Close faucet and allow tank to fill F Repeat step E four times NOTE In...

Page 8: ...2 Close tank valve on top of storage tank 3 Turn off water to RO system at the cold water supply or at the feed water supply adapter 4 Open drinking water faucet to relieve pressure 5 Locate tubing pe...

Page 9: ...sure to install cartridges in proper housings see diagram below 8 Screw bottoms of housings back onto caps securely do not over tighten Turn on cold water supply Check for leaks Continue to check peri...

Page 10: ...system to catch any water that spills during removal of the filter housings 2 Open drinking water faucet to drain tank When tank is drained close faucet 3 Disconnect the tubing connections from the G...

Page 11: ...e system is producing water by turning off the valve on the storage tank and opening the faucet Water should drip from faucet 1 Examine the pre filters If clogged replace see Replacing the Pre Filters...