background image

TBOS-II™ FIELD TRANSMITTER

 

 

Field transmitter (Radio/IR compatible)

 

868 (EU, South Africa)

915 (US, Canada, Mexico, Australia)

DRAFT

Summary of Contents for TBOS-II

Page 1: ...TBOS II FIELD TRANSMITTER Field transmitter Radio IR compatible 868 EU South Africa 915 US Canada Mexico Australia DRAFT...

Page 2: ...r or an experienced radio TV technician for help IC STATEMENT RSS Gen Transmitter Antenna Under Industry Canada regulations this radio transmitter may only operate using an antenna of a type and maxim...

Page 3: ...II system 3 Description of the system 4 New features of the TBOS II system 4 General menu of the TBOS II field transmitter Interactions between the TBOS II field transmitter and the TBOS II control mo...

Page 4: ...radio module etc The new programming module also includes new features that will provide additional benefits for the management of your TBOS and or TBOS II modules A PRESENTATION OF THE TBOS II RADIO...

Page 5: ...customisation 3 New features of the TBOS II system The TBOS II field transmitter FT Language selection Miscellaneous display settings Storage of 3 saved programs in the in the field transmitter once...

Page 6: ...rnal radio antenna Sealed Class IP44 Backlit dot matrix 7 key keypad Built in infrared cord 2 AAA rechargeable NiMh batteries in the back Radio Main menu ON Scroll upwards through the menus Increase t...

Page 7: ...e please set the following 2 Field transmitter configuration Once the field transmitter is charged you can make initial setting adjustments namely Date and time settings Contrast adjustment Setting th...

Page 8: ...nu and confirm by pressing OK Set the contrast level using the ON OFF keys and confirm by pressing OK Setting the console name 16 letters and numbers Select Name from the Parameters screen and confirm...

Page 9: ...le and its stations Saving of program in the control module The field transmitter can also add the Rain Delay function to all TBOS control modules It has 6 memory storage areas that can store 6 differ...

Page 10: ...m by pressing OK You can then choose a specific watering cycle Week custom cycle Even numbered days Odd numbered days if the last day of the month is an odd numbered day watering will not be performed...

Page 11: ...or C to be assigned to each valve 1 to 6 using the ON OFF keys then go to hours and minutes by pressing arrows Enable the input with OK Confirm by pressing OK Start times Transmitting the time date an...

Page 12: ...etsetat300 forthecurrentmonth Theeffectivewateringruntimewillbe15min 10x50 x300 15 onprogramAand120min 20x200 x300 120 onprogramB The water budget does not apply to manual actions The maximum watering...

Page 13: ...screen Confirm the transmission by pressing OK 2 Manual actions Select Manual watering in the TBOS IR welcome screen and confirm by pressing OK Then select the type of manual action to be performed S...

Page 14: ...n sequence The program data is then transmitted to the TBOSTM control module Testing watering on all channels Select Test all stations and confirm by pressing Then set the watering test run time 1 to...

Page 15: ...Program memories from the TBOS IR welcome screen and confirm by pressing OK Then choose between two options Save the data in the field transmitter or Restore the data The Restore function allows you t...

Page 16: ...or ease of identification and thus simpler programming system operation The control module will thus contain the saved program and the active program Both are stored in the memory in case of a power f...

Page 17: ...radio products TBOS II field transmitter and radio inter face unit must have the same network number in order to communicate with one another Radio tagging is performed only once in the lifetime of t...

Page 18: ...y program that will be transfer red causing the loss of the interface unit s program To prevent this happening you must remove the radio interface unit from the old control module if you which to perf...

Page 19: ...n is completed the TBOS list screen is displayed with the characteristics of each module TBOS module name max 12 characters The battery charge level icon of the TBOS II module 0 to 3 bars or the TBOS...

Page 20: ...ntication problem Communication cannot be established between the items of equipment This authetication phase between the TBOS II field transmitter and the radio interface unit controller ensures that...

Page 21: ...ainbird eu www rainbird com tr Rain Bird Sweden AB Fleningev gen 315 254 77 Fleninge SWEDEN Tel 46 42 25 04 80 Fax 46 42 20 40 65 rbs rainbird eu www rainbird se Rain Bird Deutschland GmbH Oberjesinge...

Reviews: