DESCRIPTION OF CONTROLS

    

Refer

 to 

Figure 1

A. HOUR DIAL with 23 CYCLE START PINS:

  The HOUR dial contains 23 pins for

scheduling automatic "Starts" on any hour (except midnight - which is day changeover
time). Embossed characters provide quick identification for each hour, AM or PM,
noon and midnight. Captive type pins are designed for simple push-pull operation.

B. DAY DIAL with 14 SCHEDULING PINS:  

The calendar DAY dial contains 14 cap-

tive pins for scheduling irrigation everyday or any day within a two week range. Each
pin represents a 24 hour period beginning at midnight. Embossed characters are on
the dial, adjacent to each day of the week.

C. STATION SELECTOR/INDICATOR DIAL:

  The STATION selector/indicator dial

contains the timing controls for each of the stations. The dial automatically rotates dur-
ing a watering cycle with the current station appearing at the top under the station
pointer. REST indicates the system is off and no watering is taking place. The dial is
also used for manual selection of any station for semi-automatic operation.

Figure 1

Summary of Contents for RC-4C

Page 1: ...L with 14 SCHEDULING PINS The calendar DAY dial contains 14 cap tive pins for scheduling irrigation everyday or any day within a two week range Each pin represents a 24 hour period beginning at midnig...

Page 2: ...ll struggling with your old sprinkler timer Having a hard time complying with local watering restrictions Upgrading to a new Rain Bird sprinkler timer is easier than you might think New timers are eas...

Page 3: ...iminates controller output to the system valves without interrupting the clock operation F CIRCUIT BREAKER RESET BUTTON Circuit overload reset button F A built in circuit breaker protects the controll...

Page 4: ...TING 1 Choose a location that provides a minimum clearance of 13 wide x 10 high Since the electrical connections are provided at the bottom of the cabinet clearance should be allowed for the conduit c...

Page 5: ...ction with a 1 2 conduit fitting 3 Connect a 120 Volt A C supply line to the LINE INPUT leads Main Power Wiring RC 7C RC 4C RC 1260C The 120 VAC step down transformer is mounted in the lower left hand...

Page 6: ...ve each circuit for proper operation Upon satisfactory checkout of the system proceed to adjust the controller clock CAUTION Dead Heading a pump running the pump s motor without water flowing through...

Page 7: ...pin s corresponding to the day s on which watering is desired Re member each DAY pin represents a 24 hour period beginning at midnight 2 Next select the desired starting time s and push in the corresp...

Page 8: ...l operate for the time set on the dial after which the remaining stations will follow in sequence until the REST position again ap pears under the Station pointer RAIN SHUTDOWN There may be occasions...

Page 9: ...nsufficient cycle time al lowed b Total cycle time coincides with a succeeding START pin a Adjust cycle time for more than 15 minutes b Reset the HOUR pins or readjust the accumulated cycle time Some...