Certifications

EU Declaration of Conformity

Rain Bird Corporation hereby declares that the 
following irrigation controllers are EU compliant.
•  The products submitted meet the requirements 

of IP24.

•  The object of the declaration described above is in conformity 

with the relevant Union Harmonization Legislation:

Product name: ESP-TM2 Irrigation Controller

Model #: ESP-TM2

Standards to 

which conform-

ity is declared:

2014/30/EU EMC Directive (EMC)
•  EN 55014-1:2006 + A2:2011
•  EN 55014-2:1997 + A1:2001 + A2:2008
2014/35/EU Low Voltage Directive (LVD)
•  EN 60335-1:2012 + A11:2014 + AC:2014
•  EN 62233:2008+AC: 2008
2011/65/EU RoHS Directive
•  EN 50581:2012

Signature:

Full name: Ryan L. Walker

Position Director

Date: March 21, 2018

Place: San Diego, CA USA

Rain Bird Corporation 

970 W. Sierra Madre 

Azusa, California 91702, 

U.S.A.

626-963-9311

Rain Bird International, 

Inc. 1000 West Sierra 

Madre Azusa, CA 91702, 

U.S.A.

Ph: (626) 963-9311 

Fax: (626) 852-7343

Rain Bird Europe 

240 Rue René Descartes 

Batiment A PARC 

CLAMAR 

BP 40072 

13792 AIX EN PROVENCE 

CEDEX 3 FRANCE

Waste Electrical and Electronic Equipment (WEEE)

As a hardware manufacturer, Rain Bird has met its 
national obligations to the EU WEEE Directive by 
registering in those countries to which Rain Bird is 
an importer. Rain Bird has also elected to join WEEE 
Compliance Schemes in some countries to help 
manage customer returns at end of life.

Safety Information 

 

WARNING

Special precautions must be taken when valve 
wires (also known as station or solenoid wires) 
are located adjacent to, or share a conduit with 
other wires, such as those used for landscape 
lighting, other “low voltage” systems or other 
“high voltage” power.
Separate and insulate all conductors carefully, 
taking care not to damage wire insulation dur-
ing installation. An electrical “short” (contact) 
between the valve wires and another power 
source can damage the controller and create a 
fire hazard.

All electrical connections and wiring runs must 
comply with local building codes. Some local 
codes require that only a licensed or certified 
electrician can install power. Only professional 
personnel should install the controller. Check 
your local building codes for guidance.

If the supply cord of an outdoor controller is 
damaged, it must be replaced by the manu-
facturer, its service agent or similarly qualified 
persons in order to avoid a hazard.
If the supply cord of an indoor controller is 
damaged, it must be replaced by a special cord 
or assembly available from the manufacturer 
or its service agent.

If the electrical cord for models ESP-TM2 AUS 
is damaged, it needs to be replaced with the 
following:
Flexible supply cord  H05VV-F
Minimum wire size of 0.75mm^2 (18 AWG). For 
Direct Connect wiring, the minimum wire size 
is 0.75mm^2 (18 AWG).

Outdoor controller shall be permanently con-
nected to fixed wiring by a flexible cord, and 
have a cord anchorage. The cord anchorage 
shall relieve conductors from strain, including 
twisting, at the terminals and protect the insu-
lation of the conductors from abrasion.

NOTICE

Use only Rain Bird approved accessory devices. 
Changes or modifications not expressly 
approved by Rain Bird could void the user’s au-
thority to operate the equipment. Unapproved 
devices may damage the controller and void 
the warranty. For a list of compatible devices 
go to: www.rainbird.com

Changes or modifications not expressly 
approved by Rain Bird could void the user’s 
authority to operate the equipment.
Date and time are retained by a lithium battery 
which must be disposed of in accordance with 
local regulations.
Model, serial number, supply rate, manufactur-
ing country and fabrication date are located on 
the back of the wiring bay cover.

 

CAUTION

This appliance is not intended for use by 
persons (including children) with reduced 
physical, sensory or mental capacity, or lack 
of experience and knowledge unless they 
have been given supervision or instruction 
concerning use of the appliance by a person 
responsible for their safety. Children should be 
supervised to ensure that they do not play with 
the appliance.

This appliance can be used by children aged 
from 8 years and above and persons with re-
duced physical, sensory or mental capabilities 
or lack of experience and knowledge if they 
have been given supervision or instruction 
concerning use of the appliance in a safe way 
and understand the hazards involved.  Children 
shall not play with the appliance.  Cleaning 
and user maintenance shall not be made by 
children without supervision.

Stationary appliances not fitted with means for 
disconnection from the supply mains having 
a contact separation in all poles that provide 
full disconnection under overvoltage category 
III, the instructions state that means for dis-
connection must be incorporated in the fixed 
wiring in accordance with the wiring rules

Rain Bird ESP-TM2 
on the Web

English

www.rainbird.com
wifi-pro.rainbird.com

Español

Spain

www.rainbird.es
wifi-pro.rainbird.es

Mexico

www.rainbird.com.mx
wifi-pro-mx.rainbird.com

F rançais

www.rainbird.fr
wifi-pro.rainbird.fr

Português

www.rainbird.com.br
wifi.rainbird.com.br

Italiano

www.rainbird.it
wifi-pro.rainbird.it

Deutsche

www.rainbird.de
wifi-pro.rainbird.de

Türk

www.rainbird.com.tr
wifi-pro.rainbird.com.tr

Pусский

www.rainbirdrussia.ru
wifi-pro.rainbirdrussia.ru

Polskie

www.rainbird.pl
wifi-pro.rainbird.pl

中文

www.rainbird.com.cn

Summary of Contents for ESP-TM2

Page 1: ...Rain Birdt ESP TM2 Controller User Manual LNK TM Ready sold separately LNKTM Ready ...

Page 2: ... or serious injury CAUTION Indicates a hazardous situation that if not avoided could result in minor or moderate injury NOTICE Indicates information considered important but not hazard re lated e g messages relating to property damage SAFETY INSTRUCTIONS Specific safety related instructions or procedures are described Symbols User Operation A NUMBERS define a series of steps for the user to follow...

Page 3: ...station Seasonal Adjust Global or by program Manual Station Run Yes Manual Program Run Yes Manual Test All Stations Yes Station Advance Yes Short Detect Yes Delay Between Stations Yes Accessory Port Yes 5 pin Save Restore Programming Yes WiFi Compatible Yes with LNKTM WiFi Module WiFi Enabled The LNKTM WiFi Module allows remote connection to a Rain Bird ESP TM2 Controller using an Apple iOS or And...

Page 4: ...Route all field wires through the opening at the bottom of the unit or through the knock out in back of the unit Attach conduit if desired as shown WARNING Do not route valve wires through the same opening as power wires B Connect one wire from each valve to one of the numbered station terminals 1 12 on the controller as shown C Connect a field common wire C to the common terminal C on the control...

Page 5: ...th the ESP TM2 Description Model Volts Universal Pump Relay PSR110IC 110V Universal Pump Relay PSR220IC 220V NOTE Connection to pump and external power not shown Refer to pump installation instructions A PUMP START RELAY B C PSR 1 2 Connect Rain Freeze Sensor optional The ESP TM2 controller can be set to obey or ignore a rain sensor Refer to the Rain Sensor section under Advanced Pro gramming A Re...

Page 6: ...Use either the provided wire nuts or the installed connector for this step D Verify that all wiring connections are secure then replace the wiring compartment cover and secure it with the screw L N L N TO EXTERNAL POWER SUPPLY C A B WARNING DO NOT apply power until you have completed and checked all wiring connections POWER WIRING CONNECTIONS 230 VAC International Brown supply wire hot to the brow...

Page 7: ...rn the dial to RUN TIMES A Press Program Select to choose the desired Program if necessary B Press or to select a Station C Press or to set the Run Time for the selected Station D Press to set additional Station Run Times NOTE Rain Bird recommends that the maximum irrigation zone cycle time be less than the time required for runoff to begin and that there be adequate soak time before the next irri...

Page 8: ...Run a Single Program Start watering immediately for one program Turn the dial to AUTO RUN A Press Program Select to choose the desired Program if necessary B Press and hold to start the selected Program During Manual Watering The display shows a blinking sprinkler symbol the active Station Number or Program and the Remaining Run Time C To cancel manual watering turn the dial to OFF for three secon...

Page 9: ...ll is detected When set to BYPASS all programs will ignore the rain sensor Turn the dial to SENSOR A Press or to select ACTIVE obey or BYPASS ignore Obey sensor Ignore sensor Rain detected flashing NOTE See Special Features to set Rain Sensor Bypass by Station Seasonal Adjust Increase or decrease program run times by a selected percentage 5 to 200 Example If the Seasonal Adjust is set to 100 and t...

Page 10: ...ures A Turn the dial to the desired position B Press and hold and at the same time SET INTERSTATION DELAY A station delay from 1 second to 9 hours ensures that a valve has completely closed before the next one opens RESET TO FACTORY DEFAULTS All programmed schedules will be erased SET RAIN SENSOR BYPASS BY STATION Tells a station to obey or ignore a rain sensor SAVE PROGRAMMING RESTORE PROGRAMMING...

Page 11: ...t from the controller terminal block and replace it with a jumper wire connecting the two SENS terminals Jumper wire connecting the two SENS terminals may be missing or damaged Jumper the two SENS terminals on the controller terminal block by connecting them with a short length of 14 to 18 gauge wire Solenoid or master valve is shorted Confirm short message on the display Correct the issue in the ...

Page 12: ... it needs to be replaced with the following Flexible supply cord H05VV F Minimum wire size of 0 75mm 2 18 AWG For Direct Connect wiring the minimum wire size is 0 75mm 2 18 AWG Outdoor controller shall be permanently con nected to fixed wiring by a flexible cord and have a cord anchorage The cord anchorage shall relieve conductors from strain including twisting at the terminals and protect the ins...

Page 13: ... conserve water has never been greater We want to do even more and with your help we can Visit www rainbird com for more information about The Intelligent Use of Water Rain Bird Corporation 6991 East Southpoint Road Tucson AZ 85756 USA Tel 520 741 6100 Rain Bird Corporation 970 West Sierra Madre Ave Azusa CA 91702 USA Tel 626 812 3400 Rain Bird International 1000 West Sierra Madre Azusa CA 91702 U...