Before You Begin:

Please refer to your ESP-LX PLUS Installation,

Programming, & Operation guide for answers to questions

regarding installation and connection (valve wires, etc) of

an ESP-LX PLUS Controller.

NOTE:

When Setting the Time and Date on

startup of the ESP-LX PLUS SITE Controller,

the ESP-LX PLUS SITE defaults will be MON

12:00 26 MAY 03. Dates earlier than this can

not be set in this controller. ESP-LX PLUS

Controllers (per the manual) default to SUN

12:00 1 JAN 95.

Installation instructions in this addendum assume conver-

sion of an existing ESP-LX PLUS Controller to an ESP-LX

PLUS SITE Controller using the ESP-LX PLUS SITE

Module Kit. If purchase of a new ESP-LX PLUS SITE

Controller was made, instructions specific to the Module

Kit (transformer replacement, etc) may be ignored.

Warnings:

Important:

The ESP-LX PLUS SITE Controller is

designed to operate up to 4 valve stations

plus one Master Valve, simultaneously. It is

necessary that only one Rain Bird valve sole-

noid be connected to each valve station in the

controller.

Important:

Before installing the Site Satellite

Maxicom Interface Site Board (MISB) cabinet,

make sure that the area around you is free

from dirt and dust and that your hands and

arms are clean. This will avoid contamination

of the controller’s internal parts.

Warning!

Don’t let water or other liquids come

in contact with any part inside the controller

cabinet.

Caution:

This controller contains a Lithium bat-

tery. Danger of explosion if battery is incorrect-

ly replaced. Replace only with the same or

equivalent type recommended by the manu-

facturer. Dispose of used battery according to

the manufacturer’s instructions

Summary of Contents for ESP-LX Plus Series

Page 1: ...nd Settings 120 VAC 60 Hz Models ESPLX16STE ESPLX20STE ESPLX24STE ESPLX16STM ESPLX20STM ESPLX24STM 230 VAC 50 Hz Models IESPLX16ST IESPLX20ST IESPLX24ST IESPLX16SM IESPLX20SM IESPLX24SM 240 VAC 50 Hz...

Page 2: ...to the Module Kit transformer replacement etc may be ignored Warnings Important The ESP LX PLUS SITE Controller is designed to operate up to 4 valve stations plus one Master Valve simultaneously It i...

Page 3: ...SITE Satellite controller you must install the Maxicom Interface Site Board Cabinet Once installed the MISB allows your ESP LX PLUS controller to function as either an ESP LX PLUS SITE controller in c...

Page 4: ...is cable includes 36 91 4 cm length designed to be outside the two cabinets Allow enough length for vertical passage through electrical conduit prior to determining horizontal length available It is r...

Page 5: ...ller Addendum 5 ESP LX Plus Controller Cabinet MISB Cabinet Primary Power Valve Wires Phone Cable Sensor Wires MISB Data and Power Cables Minimum 9 1 2 24 2 cm Maximum 15 38 1 cm Recommended 6 15 2 cm...

Page 6: ...xisting transformer Disconnect the transformer from the ESP LX PLUS ter minal board With the door and face panel removed locate the high voltage compartment in the lower left corner of the controller...

Page 7: ...onnect the power input wires to the main power source If you have the standard 120 volt 60 Hz model use wire nuts to connect the black wire to the power source hot wire the white wire to the common wi...

Page 8: ...nce is based on cabinet mounting recommended minimum distance between cabinets is 91 2 24 1 cm In the MISB Cabinet The bottom center of the MISB Cabinet has a knock out for a PVC male adapter sized 1...

Page 9: ...ESP LX Plus Site Satellite Controller Addendum 9...

Page 10: ...the wire In the LX PLUS Controller Cabinet Install the ESP LX Plus SITE front panel on the LX PLUS controller Connect the ribbon cable and two wire har ness from the face panel to the controller s ci...

Page 11: ...ESP LX Plus Site Satellite Controller Addendum 11 REMOTE STAND ALONE CENTRAL CONTROL...

Page 12: ...uit is recommended for both phone and sensor cables wires Serial Port RS 232 Connect the cable assembly modem site into the DB 9 Connector and the opposite end to the modem Set S2 to RS 232 position I...

Page 13: ...LX Plus Site Satellite Controller Addendum 13 DTE DCE Switch Phone RS232 Switch J1 Data Connector CCU PROM Chip Sensor Ports Serial Connector Ground Terminal Phone Connector W1 Jumper J4 Power Connec...

Page 14: ...ire does not enter securely into the hole press down on the lever as you insert the wire Route the wires through the knockout for a PVC male adapter sized 3 4 1 9 cm on the right hand side of the cabi...

Page 15: ...ESP LX Plus Site Satellite Controller Addendum 15 REMOTE STAND ALONE CENTRAL CONTROL...

Page 16: ...s Refer to the troubleshooting section Page 3 if the status light is not lit or is not blinking Reset Button In addition to canceling active schedules at the ESP LX PLUS SITE you can use the reset but...

Page 17: ...ESP LX Plus Site Satellite Controller Addendum 17 DTE DCE Switch Phone RS232 Switch CCU PROM Chip ESP SAT MIB Chip W1 Jumper Reset Button Status Light...

Page 18: ...ol Unit Board It typically is labeled with a large white sticker The PROM chip rests inside a plastic cradle Using the tabs at either end of PROM chip gently wiggle the chip and lift it straight up un...

Page 19: ...t will not function when it is sent to the ESP LX PLUS SITE Solution Verify channel assignment on ESP LX PLUS SITE matches maximum PC channel assign ments The ESP LX PLUS SITE has a maximum number of...

Page 20: ...nt into an outlet on a circuit differ ent from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Changes or modifications not expressly approved...

Reviews: